FBO DAILY - FEDBIZOPPS ISSUE OF MAY 25, 2014 FBO #4565
SOURCES SOUGHT

N -- Provide all necessary equipment, programming, startup, and training services to provide a complete diesel generator system at Wright Patterson AFB

Notice Date
5/23/2014
 
Notice Type
Sources Sought
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
USACE District, Louisville, 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville, KY 40202-2230
 
ZIP Code
40202-2230
 
Solicitation Number
W912QR-14-WPAFBGENERATORS
 
Response Due
6/9/2014
 
Archive Date
7/22/2014
 
Point of Contact
Lisa Duffy, 502-315-6198
 
E-Mail Address
USACE District, Louisville
(lisa.a.duffy@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
A market research is being conducted to determine if there are a reasonable number of interested businesses that can meet the requirements proposed below. If your firm is capable of meeting the requested requirements and you are interested in this project please respond appropriately, negative responses are also encouraged. The proposed project is for the following: Both of the existing Kohler generators (Model #2000REOZDB) will need to be disconnected from the existing paralleling switchgear and connected to the new paralleling gear. The DEC-550 controls are in the generator enclosures with each generator, and the controls in the switchgear are primarily Modicon Momentum PLC's. The existing switchgear will be kept in service and will be used for the utility point of common coupling and to connect to the new generator paralleling switchgear and the protected load. The successful Contractor will need to provide all necessary equipment, programming, startup, and training services to provide a complete system with the following functions: Utility Connected Operation - protected load served by utility feed only. Both utility and load breakers are to remain in the existing switchgear Generator Connected Operation - protected load served by new and existing generators connected to new paralleling gear with load breakers remaining in existing switchgear (via tie between new and existing switchgear) Closed Transition Between Utility and Generator Connected Operation - the system shall provide a synchronized closed transition between utility and islanded operation and between islanded and utility operation. Generator Test Mode - the new paralleling gear shall be provided with a breaker for a load bank to be connected. The system shall allow the generators to be operated on the load bank completely isolated from the utility and load breakers in the existing switchgear. Future Second Protected Load Feed - The paralleling gear shall be provided with a spare breaker for the purpose of supporting a future isolated load served by a second utility feeder. This second system shall have all of the same features as the existing system. It will not be necessary to interconnect both systems at the same time. Due to the nature of the load being protected, minimal downtime and maximum reliability of the final system are required. The successful Contractor will need to complete all work associated with the reconnection of the system and its testing and startup in less than a week's time. Submission Requirements: 1)Documentation of product meeting the Buy American Act 2)Document of the product meeting FAR Part 23.203 and Federal Energy Management Plan All interested contractors should respond to this survey by 9 June 2015 by 1400 hrs Eastern Standard Time. Responses to this sources sought notice should include: (1) Identification and verification of the company's business status. (2) The requested submission requirements as noted above. Email responses to Lisa Duffy at Lisa.A.Duffy@usace.army.mil or mail to The US Army Corps of Engineers, Louisville District, 600 Martin Luther King Jr. Place, Room 821, and ATTN: Lisa Duffy, Louisville, KY 40202-2267. If you have questions please contact Lisa Duffy at Lisa.A.Duffy@usace.army.mil. This is NOT a Request for Proposal and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market research.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-14-WPAFBGENERATORS/listing.html)
 
Place of Performance
Address: USACE District, Louisville 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville KY
Zip Code: 40202-2230
 
Record
SN03375318-W 20140525/140523234355-8f83a3ed509b5f5b8db8e8a9aa259817 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.