DOCUMENT
41 -- Replace SICU Chiller - Attachment
- Notice Date
- 6/3/2014
- Notice Type
- Attachment
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 8 (248);Room 315, Bldg. 2;10,000 Bay Pines Blvd;Bay Pines FL 33744
- ZIP Code
- 33744
- Solicitation Number
- VA24814Q1101
- Response Due
- 6/19/2014
- Archive Date
- 7/19/2014
- Point of Contact
- Chris LaShure
- Small Business Set-Aside
- Total Small Business
- Description
- NAICS 333415 will be used for this solicitation. Provide to me in an email your product comparison sheet. In the subject line of the email use "Replace SICU Chiller". The product must be manufactured in the USA by a small business. Specs for Air Cooled Scroll Chiller (110 tons) ?Galvanized steel frame, panels and access doors. ? Surfaces are finished with a powder-coated paint. ? Unit ships with full operating charge of refrigerant (R-410) and oil. ? The unit is equipped with two or more hermetic, direct-drive, 3600 rpm 60 Hz (3000 rpm 50 Hz) suction gas-cooled scroll compressors. ? Braze plate evaporator is made of stainless steel with copper as the braze material. It is designed to withstand a refrigerant side working pressure of 430 psig (29.6 bars) and a waterside working pressure of 150 psig (10.5 bars). ? The evaporator is covered with factory-installed 0.75 inch (19.05 mm) Armaflex II or equal (k=0.28) insulation. Foam insulation is used on the suction line. ? Air-cooled condenser coils have aluminum fins mechanically bonded to internally-finned copper tubing. ? Direct-drive vertical discharge condenser fans are balanced. Three-phase condenser fan motors with permanently lubricated ball bearings and external thermal overload protection are provided. ? Microprocessor-based control panel factory-installed and factory-tested. ? Refrigerant isolation valves (discharge valve) ? Factory installed water strainer ? Factory installed Electronic Flow Switch ? Across the line starter ? Single point power connection ? Circuit breaker ? LonTalk Tracer Summit Interface ? UL Listed ? ARI Certification ? ASHRAE 90.1 compliant ? Architectural louvered panels ? Elastomeric isolators ? 460V/3Ph/60 Hz ? Startup supervision by Technician (Regular Hours: M-F 8:00am - 5:00pm) ??Dual high head pump - up to 80 ft of H2O ? Pump flow ctrl by variable speed drive ? Extended 5 years Warranty (Parts) ? Adsil Anti-Corrosive Application
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BPVAMC/VAMCCO80220/VA24814Q1101/listing.html)
- Document(s)
- Attachment
- File Name: VA248-14-Q-1101 VA248-14-Q-1101_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1401550&FileName=VA248-14-Q-1101-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1401550&FileName=VA248-14-Q-1101-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-14-Q-1101 VA248-14-Q-1101_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1401550&FileName=VA248-14-Q-1101-000.docx)
- Place of Performance
- Address: VA Caribbean Healthcare System;10 Calle Casia;San Juan, PR
- Zip Code: 00921
- Zip Code: 00921
- Record
- SN03384142-W 20140605/140603235259-61dea42c0a8845bf67a6870d8b593ecb (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |