Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 13, 2014 FBO #4584
SOLICITATION NOTICE

61 -- POWER SUPPLY, MODULE & TRANSMITTER

Notice Date
6/11/2014
 
Notice Type
Combined Synopsis/Solicitation
 
Contracting Office
PO BOX 620, Grand Coulee, WA 99133
 
ZIP Code
99133
 
Solicitation Number
40148590
 
Response Due
6/16/2014
 
Archive Date
12/13/2014
 
Point of Contact
Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
 
E-Mail Address
Clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.The solicitation number is 40148590 and is issued as an invitation for bids (IFB), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-74. The associated North American Industrial Classification System (NAICS) code for this procurement is 335999 with a small business size standard of 500.00 employees.This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2014-06-16 17:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Grand Coulee, WA 99133 The Bureau of Reclamation requires the following items, Brand Name or Equal, to the following: LI 001: POWER, SUPPLY, 24 VDC INPUT, 5 VDC OUTPUT FOR LOADS UP TO 4 AMP, OPTO 22 NO. SNAP-PS4-24DC, OR EQUAL, 5, EACH; LI 002: MODULE, SEQUENCE EVENTS RECORDER, 24, 48 OR 125 VDC INPUT VOLTAGE, 24 VOLT POWER, 8000 EVENT MEMORY, -20 CELCIUS TO +85 CELCIUS OPERATING TEMP, 0 TO 95 PERCENT NON-CONDENSING, INPUTS - 32 CONTACTS / COMPRESSION TERMINAL BLOCKS OR PLUGS, CONTAINS 1- RS-232 MODBUS PORT, 1 -RS-485 MODBUS PORT, 1 - 10/100 BASE-TX AND MODBUS TCP PORT, I/O MODULE MOUNTS ON STANDARD DIN RAIL, MODULE CONTAINS 32 INPUTS, UP TO 250 PROTIME SER CARDS CAN BE SYNCHRONIZED TOGETHER TO BUILD AN EVENTRECORDING SYSTEM WITH UP TO 8000 POINTS, THE MODULE COMMUNICATES IN MODBUS POROTCOL OVER AN RS-232 OR RS-485 CONNECTION, MODULE ALSO CONTAINS A 10/100 BASE-TX ETHERNET CONNECTION, WHICH SUPPORTS MODBUS TCP, THE MODULE COMBINESTHE FUNCTIONS OF AN EXTERNAL TIME REFERENCE INTERFACE CARD AND A SEQUENCE OF EVENTS RECORDER CARD INTO ONE MODULE, THE SER CARD CAN RECEIVE ITS TIME SYCHRONIZEDION FROM ANOTEHR SER CARDM AN IRIG-B TIME CODE SIGNAL OR A DIRECT INTERFACE TO A GPS 300 RECEIVER, THE SER CARD CAN ALSO ACT AS A TIME SYNC MASTER TO SYNCHRONIZE OTHER SER CARDS, NONAGHAN ENGINERING PROTIME 100 SERIES MODULE NO MPT-024-024-M, OR EQUAL., 5, EACH; LI 003: MODULE, DIGITAL, OUTPUT 5 TO 60 VDC, FOUR CHANNEL, DIGITAL VOLTAGE, ISOLATED, LINE VOLTAGE - RANGE: 5 TO 60 VDC, LINE VOLTAGE: 5 TO 48 VDC, CURRENT RATING: 3 AMPS PER MODULE,SURGE CURRENT: 5 AMPS FOR 1 SECOND, MINIMUM LOAD 20MA, OUTPUT VOLTAGE DRIP: 1.6 BOLTS MAX AT.75 AMPS, PEAK BLOCKING VOLTAGE: 60 VDC, CHANNEL TO CHANNEL ISOLATION: 300 VAC (1500 V TRANSIENT), LOGIC SIDE: PICKUP VOLTAGE: 4V @ 5.5MA: DROPOUT VOLTAGE: 1 VDC; CONTROL RESISTANCE: 220 OHMS, LOGIC SUPPLY VOLTAGE: 5 VDC; LOGIC SUPPLY CURRENT: 50 MAX, TURN-ON TIME: 100 MICRO SECONDS, TURN-OFF TIME: 750 MICROSECONDS ISOLATION (FIELD SIDE TO LOGIC SIDE): 4000 VOLTS, TEMPERATURE: 0 DEGREES TO 70 DEGREES C. ANGENCY APPROVALS: UL,CE, ROHS, DFARS, WARRANTY: LIFETIME. SNAP NO ODC5-I, OR EQUAL., 10, EACH; LI 004: TRANSMITTER, OPTICAL, 4 CHANNEL ANALOG, 1310NM SINGLE MODE FIBER, 4-CHANNEL ANALOG IRIG TRAMSMITTER, OPTICAL TRANSMITTER THAT CONVERTS AND ELECTRICAL IRIG A THROUGH E, INPUTS SIGNAL INTO FOUR OPTICAL OUTPUT SINGALS FOR DISTRIBUTION. SIGNAL BANDWIDTH: 100HZ TO 0.5 MHZ (+0, -3DB); INPUT / OUTPUT IMPEDENCE: 600 OHMS; INPUT / OUTPUT LEVEL: 3 VOLTS PP MAXIMUM, 5 MA; SIGNAL/NOISE RATIO: 60 DB MINIMUM (REF 1VPP); LINEARITY: 2 PERCENT TYPICAL; OPERATING WAVELENGTH: 850, 1310, 1550NM; OPTICAL OUTPUT POWER (TYP):-16DBM (MULTIMODE); -1 6 DM (SINGLE-MODE); OPTICAL LOSS BUDGET: 0-12DB (MULTIMODE), 0-12 DB (SINGLE MODE): OPTICAL CONNECTORS: ST (MULTIMODE), FCPC (SINGLE-MODE); SIGNAL CONNECTOR : BNC; MTBF (MI L0HDBK-21 7D): 100,000 HOURS; OPERATING TEMPERATURE: -35 TO +75 DEGREES CELCIUS; POWER REQUIREMENTS: 11-24 VAC/DC @ 350 MA; PHYSICAL SIZE (MM): 5.0 (127) X 3.0 (76) X 1.0 (25.4), LUXLINK NO IRGM-1004-7, OR EQUAL., 5, EACH; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, Bureau of Reclamation intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. Bureau of Reclamation is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 30 calendar days after close of Buy. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. See Attached Contract Clauses Technical Acceptability ranks higher than Delivery and Price. Technical Acceptability and Delivery, when combined, rank higher than Price in Evaluation Criteria. Price must be fair and reasonable. Clauses 52.212-02, Evaluation-Commercial, WBR 1452.215-71, Use and Disclosure of Proposal Information and 52.232-99, Providing Accelerated Payment to Small Business Subcontractors (Deviation), apply to this RFQ. Per FAR Clause 52.211-06, Brand Name or Equal, if quoting other than specified, you MUST attach enought literature, including picture and Specifications, for our evaluation team to determine if it meets the criteria to be considered acceptable as a replacement. Failure to do so may disqualify your quote.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/99e93fccac4c3a312e8cf89173a8a2d8)
 
Place of Performance
Address: Grand Coulee, WA 99133
Zip Code: 99133-0620
 
Record
SN03391500-W 20140613/140611234536-99e93fccac4c3a312e8cf89173a8a2d8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.