Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 20, 2014 FBO #4591
SOLICITATION NOTICE

66 -- Integrated upgrade package for a Government owned Nikon Eclipse TIRF microscope to perform 3D Stochastic Optical Reconstruction Microscopy (STORM) imaging capabilities

Notice Date
6/18/2014
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, National Cancer Institute, Office of Acquisitions, 9609 Medical Center Drive, Room 1E128, Rockville, Maryland, 20852, United States
 
ZIP Code
20852
 
Solicitation Number
N02RC42546-83
 
Archive Date
7/17/2014
 
Point of Contact
Gwennifer K. Epps, Phone: 240-276-5445, Terry Galloway, Phone: 240-276-5384
 
E-Mail Address
eppsg@mail.nih.gov, gallowaytl@mail.nih.gov
(eppsg@mail.nih.gov, gallowaytl@mail.nih.gov)
 
Small Business Set-Aside
N/A
 
Description
The National Cancer Institute (NCI), Center for Cancer Research (CCR), Laboratory of Cellular and Molecular Biology (LCMB), plans to procure an integrated upgrade package for a Government owned Nikon Ti Eclipse TIRF microscope on a sole source basis with Nikon Instruments Inc. 1300 Walt Whitman Road - Melville, NY 11747. This acquisition will be processed in accordance with commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The pre-solicitation number is N02RC42546-83. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC 20) 05-72, (January 2014) Simplified Procedures for a Commercial Item. The Government contemplates only one award of a Firm-Fixed Price contract. The Associated North America Industry Classification Code (NAICS) 334516 and the Business Size Standard are 500. It has been determined there are no opportunities to acquire green products or services for this procurement. Delivery will be 60-90 days from date of award. The Laboratory of Cellular and Molecular Biology (LCMB) investigates normal cellular signal transduction and aberrations in signaling pathways that are associated with neoplasias in humans and model systems. LCMB scientists have been very successful in using imaging approaches to study these topics. Five years ago, NCI acquired a Nikon TIRF microscope and the LCMB began to develop techniques using Photo Activation Localization Microscopy (PALM), which allows localization of genetically encoded proteins to within 20 nm. This project has been very successful, resulting in several publications. As a result, NCI would now like to expand its super-resolution capabilities to include Stochastic Optical Reconstruction Microscopy (STORM), which allows localization of antibody labeled molecules. STORM will allow NCI to resolve the location of endogenous proteins and phosphorylated proteins to within 20 nm, a significant expansion of the LCMB high resolution capabilities. Projects are underway to determine the composition and time dependent changes in protein complexes formed during the activation of receptors at the single molecule level. Once the upgrade is implemented, the system can be used for both PALM and STORM imaging by any investigator who uses the LCMB Microscopy Core. The Laboratory of Cellular and Molecular Biology (LCMB) requires improvement to the LCMB's TIRF microscope for experiments involving the observation of endogenous or phosphorylated proteins with resolution of structures to within 20-40 nm in three dimensions by Stochastic Optical Reconstruction Microscopy (STORM). These experiments require imaging equipment with sufficient sensitivity to visualize single molecules, lasers powerful enough to use the STORM technique and software capable of producing STORM images. The integrated upgrade package from Nikon Instruments Inc. possesses the following salient characteristics: 1) Modifications must allow use of current microscope (Nikon Eclispe Ti), 100X TIRF objective NIH decal #01751173. 2) The combined outcome of these modifications must be to allow both PALM and STORM imaging with 3D capabilities, while maintaining TIRF and epifluorescence capabilities, 3) Addition of STORM components: Ti-TIRF motorized illuminator Unit, TI-N-STORM kit, iXON DU897 Ultra 512x512 EM-CCD camera, stage up brackets, 4) Addition of filter wheels: Lambda 32 nm filter wheel, Lambda 25 nm emission filter wheel, TI emission adapter, HS-625 filter wheel setup for digital triggering with external breakout box and adaptors for same, excitation adapter 5) Lambda 10-3 controller, 6) TIRF dichroics and filter sets: STORM quad filter set, STORM 647 filter set, 89000 Sedat Quad ET filter set mounted TiTE2000, Custom 440/514/561/649 filter MTD TIRF, FL STIC filter set, ET430/24x, ET CFP Excitation Filter 32mm, YFP Exciter 32mm, ET480/40m, Hard Coat Emission Filter, ET525/36m Emission Filter, max blocking for 488 & 561 laser lines. 25mm diameter, max 5mm thick, ET705/72m Emission Filter, Far Red Emission for SpectraX quad band 25mm, ET500LP, ET 500nm Long Pass Emission Filter 25mm, ET520LP, Long Pass Emission Filter 25mm, ET570LP, Long Pass Emission Filter 25mm, ET545/40m, Band Pass Emission Filter 25mm, Polarizing Filter (25 mm or smaller), 7) Piezo Z for 3D STORM: Piezo Stage Insert with USB Controller, Petri Dish Holder 35MM for Piezo Stage, Slide Holder 1x3 for Piezo Stage, Cover Slip Holder 1x1 for Slide Holder 1x3 for Piezo Stage, Multi-Well Plate Holder for Piezo Stage, 8) 6 Line solid state laser combiner: LUNB Solid state laser combiner: 405S/445S/488H/514S/561H/647X A/A/F, NIDAQ LUnB Connection kit: includes breakout box for NI6723 and NI6353cards, all connectors, and interlock cable, NI PCIe-6353 DAQ card - 32AI and 48 I/O lines. Requires x2 77013227cables, NI PCI6723 DAQ Card (PCI) - 32 channel DAQ card. Compatible with77013226 break-out box and 77013230 cable connector. Note: to access all 32 channels by software, 2 breakout boxes and 2 cables are required, SHC68-68-EPM, 68-D-Type to 68 VHDCI Offset, 2 m; Extended Performance Shielded, Cable for NI X Series, M Series. For use with 77013226 (BNC-2110) 9) Software and PC workstation: NIS-Elements: Advanced Research: Acquisition and analysis package, includes camera and Nikon motorized microscope drivers. Included modules: Advanced interpreter, live compare, and time measurements. Optional modules include 6D acquisition, Real time Deconvolution and EDF. Note separate drivers are required for device control, STORM Analysis, NIS-Elements: Module: 6D imaging - acquisition module for 6 dimensional imaging, includes time, channel or wavelength and focus, multipoint or multi stage position. Note that device drivers are required, and only available in Advanced Research package, NIS-Elements: Wavelength Switcher, NIS-Elements: Hardware Module: Wavelength control - device control for Sutter, Prior and Unibliz illumination devices including shutters and filter wheels, NIS-Elements: Triggered Device Control, NIS-ELEMENTS ILLUMINATION SEQUNCE FOR FLEXIBLE TRIGGERED LASER/LEDEXPERIMENT SETUP. AVAILABLE FOR C AND AR ONLY, NIS-Elements: Hardware Module: Motorized Focus Control - device control for external motorized focus control. Includes Prior, Maerzhauser, Nikon RFA, and PI Piezo Z drive(note that piezo is via RS232 only), Custom Cable for 6723 DAQ to 16 BNC, 64 bit Imaging workstation supplied with Intel Xeon 3.5GHz 6 core processor, 64GB DDR3 RAM, dual 7200RPM SATA drives: a 1TB OS and 3TBdata drive, and 2GB graphics display card. Optical DVD-RW, gigabit LANadapter, x5 USB2.0 and x4 USB3.0 ports, x1 IEEE1394a port, keyboard and laser mouse, and recover software is included. Windows 7 64bitProfessional edition installed. Includes 3 years parts, labor, and onsite service standard warranty. Kit includes display port to DVI-D adapter. 10) Installation of upgrades, integration, and training of users Nikon Instruments, Inc. is the only known contractor that can provide an integrated upgrade package to the Government owned Nikon TIRF microscope with the aforementioned salient characteristics. This is not a solicitation for competitive quotations. However, if any interested party believes they can meet the above requirement, especially small businesses, they may submit a tailored statement of capabilities. All information furnished must be in writing and must contain sufficient detail to allow the NCI to determine if it can meet the above unique specifications described herein. An original and one copy of the capability statement must be received in the NCI Office of Acquisitions on or before 11:00 AM EST on, July 2, 2014. No electronic capability statements will be accepted (i.e. email or fax); an original and one copy must be sent to the NCI Office of Acquisitions at the address stated above. All questions must be in writing and can be faxed (240) 276-5401 or emailed to Gwennifer Epps, Contracting Officer at eppsg@mail.nih.gov. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. In order to receive an award, contractors must have valid registration and certification in the Central Contractor Registration (CCR) and the Online Representations and Certifications Applications (ORCA), through the System for Award Management (SAM) www.sam.gov. No collect calls will be accepted. Please reference solicitation number: N02RC42546-83 on all correspondence.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/RCB/N02RC42546-83/listing.html)
 
Place of Performance
Address: NCI - Laboratory of Cellular and Molecular Biology, Building 37, Bethesda, Maryland, 20892, United States
Zip Code: 20892
 
Record
SN03398689-W 20140620/140619021719-a1bb65fb0672703f01846155d4530493 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers