DOCUMENT
66 -- 502-14-3-084-0060 - Prosim Vital Signs simulator (Alexandria) - VA256-14-AP-7065 Signal Generators and Life Vital Sign Simulators for Biomedical Engineering - Attachment
- Notice Date
- 6/19/2014
- Notice Type
- Attachment
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- DEPARTMENT OF VETERANS AFFAIRS;ALEXANDRIA VA HEALTH CARE SYSTEM;P&C DEPARTMENT (90C);PO BOX 69004;ALEXANDRIA LA 71360-9004
- ZIP Code
- 71360-9004
- Solicitation Number
- VA25614Q1078
- Response Due
- 7/2/2014
- Archive Date
- 8/1/2014
- Point of Contact
- Paul G Filhiol
- E-Mail Address
-
6-4206<br
- Small Business Set-Aside
- Woman Owned Small Business
- Description
- This is a procurement of Signal Generators and Vital Sign Simulators used to test Defibillators and Monitors in Biomedical Engineering. Please see the schedule in the attached RFQ for a full description of the required items. Items noted as being "Brand Name or Equal" in the RFQ have their salient charachteristics described below. This is a Woman-Owned Small Business set-aside. Quotes can be emailed to paul.filhiol@va.gov until closing on 2 July at 6:00PM ET. Salient Characteristics for Equal Items 6/19/2014 Brand Name Item: Impulse 7000DP Defibrillator Test, External Pacer Analyzer 1)Essential/significant physical, functional, or performance characteristics. -Lown, Edmark, trapezoidal, biphasic, and pulsed-biphasic defibrillation technology compatibility -AED compatibility -12 lead ECG simulation -Internal Pacer brand selections -Flexible heart-rate setting at 1BPM increments -Accuracy of +/- 1% of reading +0.1J -Rechargeable Battery -LCD display -Battery Charger -In accordance with safety standards: CE:IEC/EN61010-1 2nd edition; Pollution degree 2 CAN/CSA-C22.2 No. 61010-1; UL61010-1 C-Tick -Range of.1Joule-600Joule -Load resistance of 50 ohms -Pulse Trigger level of 20V -Pulse Width range of 1ms-50ms -Voltage range of 20V-5000V -Current range of.4A-100A -Charge time measurement with range of.1s-100s -Synchronization test -Automated Defibrillator test ECG waves -Carrying Case a)Compatibility b)Dimensions c)Weight d)Industry Standard-IEC 60601-2-4 Compliance e)Purpose - quality assurance testing on all vital monitor equipment at the Alexandria VA f)Governing Body or Organization - 2)Complete generic identification - Defibrillator and Automated External Defibrillator tester to conduct quality assurance testing, calibration, and safety inspections. 3)Applicable model/make/catalog number - Impulse 7000DP Defibrillator Tester, External Pacer Analyzer 4)Manufacturer name - Fluke Biomedical Per VAAR 811.104 and 811.105, I certify the following regarding the above information: "The salient characteristics listed above are essential to the Government's requirements. "To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. _Leigh Ruiz______________________________ Name: ? 6/19/2014 Brand Name Item: ProSim 8 Vital Signs Simulator 1)Essential/significant physical, functional, or performance characteristics. -All in one patient simulator ECG (electrocardio graph) up to 6 lead with amplitude accuracy of +/- (2% of setting +.005 mV), rate of 10-360 bpm in 1 bpm steps with accuracy of +/- 1% of setting Arrhythmia up to 50 selections Respiration Temperature 30-42 degrees celcius with accuracy of +/-.4degrees IBP (invasive blood pressure) 2 channels NIBP (Noninvasive blood pressure0 measured in mmHg or kPa with manometer range of 10-400mmHg, leak testing, pressure relief test Cardiac Output. SpO2-compatible with Nellcor, Masimo, Nonin, Nihon Kohden, Mindray, GE-Ohmeda, Philips/HP, and BCI -Direct data capture and printing functionality -internal pressure pump -continuous static pressure change -LCD color display -Lithium-ion rechargeable battery with 9 hour battery life -Battery Charger -Carrying Case -Cables to connect with Drager Infinity moniors -accessory kits a)Compatibility b)Dimensions c)Weight d)Industry Standard - Complies with IEC 61326-1:2006 e)Purpose - quality assurance testing on all vital monitor equipment at the Alexandria VA f)Governing Body or Organization - 2)Complete generic identification -.Comprehensive patient monitor tester for quality assurance and safety. 3)Applicable model/make/catalog number - ProSim 8 4)Manufacturer name - Fluke Biomedical Per VAAR 811.104 and 811.105, I certify the following regarding the above information: "The salient characteristics listed above are essential to the Government's requirements. "To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. _Leigh Ruiz______________________________ Name: ? 6/19/2014 Brand Name Item: DPM2Plus Universal Pressure meter 1)Essential/significant physical, functional, or performance characteristics. -handheld -battery operated -1%accuracy -Capability to test ophthalmology equipment, lasers, dialysis machines, automatic tourniquets, drainage devices, IV pumps, pressure gauges, ventilators, diagnostic, surgical suction devices -operating range of -698mmHg to 802 mmHg -949cmH2O to 1090 cmH2O -374 inH2O to 429 inH2O -13.5 PSI to 15.5 PSI -13.5 PSI to 100 PSI -units of measure mmHg, cmH2O, inH2O, PSI a)Compatibility b)Dimensions c)Weight d)Industry Standard e)Purpose - quality assurance testing on all vital monitor equipment at the Alexandria VA f)Governing Body or Organization - 2)Complete generic identification - Universal Pressure Meter designed to measure the positive and negative pressures of medical devices in either liquid or gaseous form to assist in repair and quality control. 3)Applicable model/make/catalog number - DPM2Plus Universal Pressure meter 4)Manufacturer name - Fluke Biomedical Per VAAR 811.104 and 811.105, I certify the following regarding the above information: "The salient characteristics listed above are essential to the Government's requirements. "To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. _Leigh Ruiz______________________________ Name: ? 6/19/2014 Brand Name Item: ESA615-10-NA220V Electrical Safety Analyzer 1)Essential/significant physical, functional, or performance characteristics. -Automated test sequences IEC60601-1 2nd Edition IEC62353 NFPA-99(Hospital) ANSI/AAMI ES-1 -ECG waveform tests and dual-lead measurements for up to 12 lead testing -two year warranty -Power Cord US with C19 Plug -NA 220V adapter kit -Power Cord NA 220V -voltage testing (mains and point to point) -range for mains voltage (90VAC RMS-132VAC RMS) -Range for accessible voltage (180 VAC RMS -264 VAC RMS) -Accuracy of +/- (2% of reading +.2V) -Earth Resistance Testing (earth and point to point) -two-wire -Current Range (0A-20A Duty Cycle (15A-20A, 5min on/5min off), (10A-15A 7min on/3 min off), (0A-10A continuous) -Leakage Current -AC+DC -AC only -DC only -Ranges (0microamps-199.9microamps, 200microamps-1999microamps, 2mA-10mA) -Leakage tests Ground Wire (earth) Chassis (enclosure) Lead to ground (patient) Lead to lead (patient auxiliary) Lead isolation (mains on applied part) Direct equipment Direct applied part Alternative equipment Alternative applied part Point to Point -Carrying Case a)Compatibility b)Dimensions c)Weight d)Industry Standard e)Purpose - quality assurance testing on all vital monitor equipment at the Alexandria VA f)Governing Body or Organization - 2)Complete generic identification - Automated and portable Electrical Safety Analyzer used to conduct electrical safety inspections on medical equipment 3)Applicable model/make/catalog number - ESA615-10-NA220V Electrical Safety Analyzer 4)Manufacturer name - Fluke Biomedical Per VAAR 811.104 and 811.105, I certify the following regarding the above information: "The salient characteristics listed above are essential to the Government's requirements. "To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. _Leigh Ruiz______________________________ Name: ? 6/19/2014 Brand Name Item: ESA615 Electrical Safety Analyzer 5)Essential/significant physical, functional, or performance characteristics. -Automated test sequences IEC60601-1 2nd Edition IEC62353 NFPA-99(Hospital) ANSI/AAMI ES-1 -ECG waveform tests and dual-lead measurements for up to 12 lead testing -two year warranty -20A at 120V current capability -voltage testing (mains and point to point) -range for mains voltage (90VAC RMS-132VAC RMS) -Range for accessible voltage (180 VAC RMS -264 VAC RMS) -Accuracy of +/- (2% of reading +.2V) -Earth Resistance Testing (earth and point to point) -two-wire -Current Range (0A-20A Duty Cycle (15A-20A, 5min on/5min off), (10A-15A 7min on/3 min off), (0A-10A continuous) -Leakage Current -AC+DC -AC only -DC only -Ranges (0microamps-199.9microamps, 200microamps-1999microamps, 2mA-10mA) -Leakage tests Ground Wire (earth) Chassis (enclosure) Lead to ground (patient) Lead to lead (patient auxiliary) Lead isolation (mains on applied part) Direct equipment Direct applied part Alternative equipment Alternative applied part Point to Point -Carrying Case a)Compatibility b)Dimensions c)Weight d)Industry Standard e)Purpose - quality assurance testing on all vital monitor equipment at the Alexandria VA f)Governing Body or Organization - 6)Complete generic identification - Automated and portable Electrical Safety Analyzer used to conduct electrical safety inspections on medical equipment 7)Applicable model/make/catalog number - ESA615 Electrical Safety Analyzer 8)Manufacturer name - Fluke Biomedical Per VAAR 811.104 and 811.105, I certify the following regarding the above information: "The salient characteristics listed above are essential to the Government's requirements. "To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture. _Leigh Ruiz______________________________ Name:
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC502/AlVAMC502/VA25614Q1078/listing.html)
- Document(s)
- Attachment
- File Name: VA256-14-Q-1078 VA256-14-Q-1078_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1442040&FileName=VA256-14-Q-1078-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1442040&FileName=VA256-14-Q-1078-000.docx
- File Name: VA256-14-Q-1078 VA256-14-Q-1078.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1442041&FileName=VA256-14-Q-1078-001.pdf)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1442041&FileName=VA256-14-Q-1078-001.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-14-Q-1078 VA256-14-Q-1078_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1442040&FileName=VA256-14-Q-1078-000.docx)
- Place of Performance
- Address: DEPARTMENT OF VETERANS AFFAIRS;ALEXANDRIA VA HEALTHCARE SYSTEM;2495 SHREVEPORT HIGHWAY;BLDG 136;Pineville, LA
- Zip Code: 71360
- Zip Code: 71360
- Record
- SN03400070-W 20140621/140619234455-cbd45902e136be03905e484dc6d4714d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |