Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 25, 2014 FBO #4596
SOURCES SOUGHT

38 -- Building 81/PML Fire Protection Upgrades

Notice Date
6/23/2014
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B130, Gaithersburg, Maryland, 20899-1410, United States
 
ZIP Code
20899-1410
 
Solicitation Number
SS_Bldg81_FireProtectionUpgrade
 
Archive Date
8/4/2014
 
Point of Contact
Robert Brackett, Phone: 3034976320, Patricia M. Bullington, Phone: 3034973106
 
E-Mail Address
robert.brackett@nist.gov, patricia.bullington@nist.gov
(robert.brackett@nist.gov, patricia.bullington@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
Building 81/PML Fire Protection Upgrades This sources sought notice is issued for information and planning purposes only and does not commit the Government to solicit or award a contract now or in the future. No solicitation is available at this time. The purpose of this notice is to identify sources with the requisite qualifications that could provide the products/services stated herein. All businesses, large and small businesses (8(a), SDB, WOSB, HUBZone, VOSB and SDVOSB) capable of performing the requirement indicated below are encouraged to respond to this notice. The National Institute of Standards and Technology (NIST) seek information on commercial vendors that are capable of providing facility fire protection upgrades. The Instrument Labs in the Boulder Precision Measurement Laboratory (PML, Building 81) at the NIST site in Boulder, CO requires smoke detection capability upgrades. Although the current system satisfies minimum code requirements for class B occupancy, a lack of smoke detection impacts mission continuity and increases the physical risk to the occupants, first responders, equipment, and facilities. The affected PML Instrument Labs without smoke detection include the equivalent of more than 160 single modules of advanced lab space (more than 45,000 net assignable square feet), supporting the work of hundreds of scientists, OFPM staff, and facilities contractors, and containing an estimated $140 million in advanced research and measurement equipment, in addition to the approximately $150 million total cost of the PML. Proposed fire detection capability upgrades would include installation of smoke detection in the instrument labs (IL), adjacent corridors, service galley, and interstitial space above the instrument labs. NIST also requires a consolidated user interface for multiple life safety/fire protection systems in the command area in Bldg 81. All design, equipment, and installation must meet the latest edition of NFPA 72. All equipment shall be site standard Notifier equipment. All existing and new Xtralis VESDA detectors in Building 81 shall be compatible with VESDAnet. New equipment needs to be compatible with the ~55 existing Xtralis VESDA detectors. Work will consist of the following tasks: Installation of approximately 25 Xtralis VESDA aspirating detectors that will serve the north labs and mechanical interstitial space located above the labs in Building 81. Lab Service Galleys: an appropriate aspirating smoke detector shall be provided for each of the 5 galleys serving the labs. Each service galley shall have individual monitoring. Pedestrian Corridors: detection for the pedestrian corridors will be spot detectors. The pedestrian corridors consist of the public areas between the lab units as well as the north and west walls. Individually addressed detectors are required. Interstitial Mechanical Space (ambient air): XTRALIS VESDA detection for the interstitial mechanical space ambient air. The existing cleanroom XTRALIS VESDA detection, consisting of 55 XTRALIS VESDA detectors, and new XTRALIS VESDA detectors will also be connected to the campus fire alarm system network. A new display (Notifier FirstVision) will be installed in the lab area for local graphic access to the systems associated with the labs. The Xtralis VESDAnet and Notifier FirstVision user interfaces will be installed in 81-1A111. Qualified businesses are encouraged to respond to this sources sought by providing the following information (1) Company name and DUNS number. (2) Documentation sufficient to demonstrate your company's ability to provide the required products/services. (3) Company size and socio-economic status if applicable (i.e. Large business, Small Business, 8(a), SDB, WOSB, HUBZone, VOSB, SDVOSB, etc.) The applicable NAICS code and small business size standard for this requirement is 238210, and $14 million. All responses are due no later than 5:00 PM MDT, Sunday, July 20, 2014 and must be submitted via email to robert.brackett@nist.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SS_Bldg81_FireProtectionUpgrade/listing.html)
 
Place of Performance
Address: 325 Broadway, Boulder, Colorado, 80305, United States
Zip Code: 80305
 
Record
SN03402663-W 20140625/140623234240-637a7141044bc2a45de1097702f4feb9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.