SOURCES SOUGHT
66 -- Ultra Low Level Gas Proportional Counter
- Notice Date
- 7/1/2014
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, 3900 NCTR Road, HFT-320, Bldg 50 | Rm 421, Jefferson, Arkansas, 72079, United States
- ZIP Code
- 72079
- Solicitation Number
- FDA-1134331
- Archive Date
- 7/30/2014
- Point of Contact
- Janice Heard, Phone: 215-717-3093
- E-Mail Address
-
janice.heard@fda.hhs.gov
(janice.heard@fda.hhs.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- Sources Sought The Food and Drug Administration is conducting market research to assess the availability of small business firms as defined by NAICS code 334516 to provide an Ultra-Low Level Proportional Counter as detailed in the requirements below. This Sources Sought is to determine the availability and capability of a small business, (ie: certified 8a, small disadvantage, HUB Zone one firms, Veteran owned small business and woman owned small businesses). This information is being sought for information and planning purposes only and shall not be construed as an Invitation for Bids, a Request for Proposals, Solicitation or Request for Quotes, or an indication that the Government will contract for the items or services herein. This notice is not to be construed as a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. The Government does not reimburse respondents for any cost associated with submission of the information being requested or reimburse expenses incurred to interested parties for responses to the sources sought. Any response received will not be used as a proposal. All information is due 15 days from the date of publication by e-mail to Janice.Heard@fda.hhs.gov **THERE WILL BE NO QUESTIONS AND ANSWER PERIOD** No phone calls will be accepted. Requirements: •Must have guard detector •Counting gas: P-10, 60 cc/min @ 10 psi •Must have gas-pro protection •Sample size: 5.1 cm (2 in.) Planchets •System capacity: 8 detectors in addition to guard detectors •Depth: 1/8, 1/4, 5/16 inch •Interface: Remote PC, instrument application software packages: for example, Protean Vesta 2000 or equivalent Performance Characteristics: •Alpha Background: typical: 0.05 cpm; warranted: 0.06 cpm •Beta Background: typical: 0.7 cpm; warranted: 0.75 cpm •Efficiency: •Po-210: 40% •Am-241: 40% •Th-230: 40% •Sr-90/Y-90: 55% •Tc-99: 35% •Cs-137: 40% •Plateau: Slope < 1.5% /100V < 2.5% /100V •Length > 1000 volts > 200 volts •Detector Uniformity: > 95% over active area •Dead Time Correction: tested to 300,000 counts per minute with < 1.5% dead time loss for each detector channel simultaneously and independently. •Alpha-Beta Crosstalk < 0.1% •Beta-Alpha Crosstalk < 0.1% •Electrical: AC Power: 117 Vac, < 1.7 A, 50/60 Hz •Dimension: Not larger than 16" (height), 32" (width), 16" (depth). •Rack dimension: No larger than 41" (width), 44.5" (depth) Respondents should supply: *Business name, DUNS number, business address, business website, business size status (i.e., SB, VOSB, SDVOSB, HUBZone SB, SDB, WOSB, LB), point of contact name, mailing address (if different from business address), phone number and email address; *Sufficient descriptive literature that unequivocally demonstrates that offered products and services meet or exceed above specifications. *All descriptive material necessary for the government to determine whether the product offered meets the technical requirements including: technical specifications, descriptive material, literature, brochures and other information, which demonstrates the capabilities of the contractor to meet the requirement. Indicate whether the organization is the manufacturer of the items or authorized reseller. If reseller, include the manufacturer's name, address and DUNS number. *If applicable, identification of the firm's GSA Schedule contract(s) by Schedule number and SINs that are applicable to this potential requirement are also requested.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/NCTR/FDA-1134331/listing.html)
- Place of Performance
- Address: 109 Holton Street, Winchester, Massachusetts, 01890, United States
- Zip Code: 01890
- Zip Code: 01890
- Record
- SN03412233-W 20140703/140702003252-f116de3166db08ffdb7e2a3eff85d5d4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |