DOCUMENT
A -- STL Research - Liquid Chromatography System - Attachment
- Notice Date
- 7/3/2014
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street;Leavenworth KS 66048
- ZIP Code
- 66048
- Solicitation Number
- VA25514Q1361
- Response Due
- 7/9/2014
- Archive Date
- 10/7/2014
- Point of Contact
- Yvonne B Kittling
- E-Mail Address
-
6-1987<br
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS DOES NOT OBLIGATE THE GOVERNMENT TO AWARD A CONTRACT OR ISSUE A SOLICITATION. This announcement is seeking information from the industry for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses. Interested parties responding to this Sources Sought Notice shall submit the following information at a minimum: (1) company name, address, point of contact with phone number, and DUNS number; (2) documentation relating to technical capability to conform to the Statement of Requirement; and (3) socio-economic status to identify business as being a SDVOSB, VOSB, SB, Woman Owned, Other than Small Business, etc. Responses to this Sources Sought Notice must be emailed to yvonne.kittling@va.gov no later than July 9, 2014, 10:00 AM EDT. Please be advised that the Government will not pay for any costs for responses and information submitted. Statement of Requirement This notice uses a Brand Name or Equal Description of the product required. This permits prospective contractors to offer products other than those specifically referenced by brand name. The St Louis VAMC is requesting a liquid chromatography system to facilitate protein and antibody purification that are required for pathogenesis and vaccinology studies. Ideally, the system would need to be equipped with the following features to ensure that it is sufficiently versatile to meet the needs of multiple users in the laboratory and others on campus: 1.Modular system liquid chromatography system that permits both scalability, and ready exchange of modules in the event of a module failure, or need for upgrade to existing equipment. 2.Inlet selection and sensors with air detector for automated sample loading. 3.Sample pumps for sample loading 4.Column control valve to accommodate multiple columns supporting more complex purification schemes and multiple user protocols 5.pH monitoring for gradients and elution conditions 6.UV monitoring to monitor elution 7.Conductivity monitoring to monitor buffer gradient conditions 8.Gradient forming capacity, mixing capability to form elution gradients 9.Integrated automated fraction collector with plates, bottles, tubes 10.Integrated software to automate gradient formation, fraction collection, and user protocols to accommodate multiple users. 29018226 AKTA pure M, including system pumps (up to 25ml/min, 20 MPa); gradient mixer; injection valve; simultaneous, triple wavelength UV detector, 190-700nm; conductivity detector (1 EA) 20912370 Inlet Valve Kit (V9-IB) (1 EA) 29012263 Inlet Valve Kit (V9-IS) (1 EA) 29027746 Sample Inlet Valve Kit (V9-IS) (1 EA) 29027745 Sample pump S9 (1 EA) 29011367 Column Valve Kit (V9-C, 5-columns) (1 EA) 29011359 pH Valve Kit (V9-pH) (1 EA) 28954215 pH electrode (1 EA) 29012261 Outlet Valve Kit (V9-O, 10 outlets) (1 EA) 29027743 Fraction collector F9-C (1 EA) 29046918 Unicorn 6.3.2 Workstation (node-locked) e-license and DVD for AKTA pure, and AKTA pilot platform. One (1) license access code sticker on DVD case. (1 EA)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25514Q1361/listing.html)
- Document(s)
- Attachment
- File Name: VA255-14-Q-1361 VA255-14-Q-1361_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1475055&FileName=VA255-14-Q-1361-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1475055&FileName=VA255-14-Q-1361-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA255-14-Q-1361 VA255-14-Q-1361_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1475055&FileName=VA255-14-Q-1361-000.docx)
- Place of Performance
- Address: Pediatric Building;4940 Parkview Place;St Louis, MO 63110
- Zip Code: 3110
- Zip Code: 3110
- Record
- SN03414862-W 20140705/140704000007-e93ba05f4ec7b6b7b5b485e493e5032f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice