Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 13, 2014 FBO #4614
SOLICITATION NOTICE

65 -- 544-14-4-090-0176 - Digital Stereotaxic Lab - 544

Notice Date
7/11/2014
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
541712 — Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
 
Contracting Office
Department of Veterans Affairs;W.J.B. Dorn VA Medical Center;6439 Garners Ferry Road;Columbia SC 29209-1639
 
ZIP Code
29209-1639
 
Solicitation Number
VA24714Q1094
 
Response Due
7/14/2014
 
Archive Date
9/12/2014
 
Point of Contact
JOSEPH LOCKE
 
E-Mail Address
.LOCKE@VA.GOV<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The Department of Veteran Affairs, Dorn VA Medical Center, 6439 Garners Ferry Road, Columbia, SC 29209 has a requirement for A Digital Lab Standard with LED Display and a Stereotaxic small animal system. The Government expects to award to a single contractor a contract which shall be Firm Fixed Price with a firm quantity and no option years. This requirement is being set-aside for Service Disabled Veteran Owned Small Business participation only. NAICS code for this requirement is 541712 with a small business size of 500 employees. Only offers from those firms regularly established in the business of providing this type of equipment will be considered. Subcontracting will not be allowed. All responsible sources may submit a proposal, which shall be considered. Any and all questions regarding this solicitation must be in writing and must include telephone number, fax number and point of contact to Attn: Joseph Locke, Contract Specialist, joseph.locke@va.gov. Please see solicitation for additional information regarding this requirement. Request Meet or Exceed the following specifications: Digital Lab Standard with LED Display Digital Stereotaxic Saves Time and Improves Accuracy Sealed electronic sensor, highly immune to outside interference and environmental conditions, have been added to each axis of the manipulator arm. Measurements are accurate to 10 microns in all three directions. Movements in all three directions are now monitored by a large, easy-to-read LED display module, with a resolution selectable from 1 mm to 10 microns. A zeroing function allows the user to set a reference point for targeting specific coordinates on the animal's skull for injection, implantation, etc. Calculation of distance measurements via the vernier scales is thus no longer necessary ¦saving the user valuable time and improving accuracy. The classic design and high quality of our conventional Lab Standard manipulators are exactly the same on the new Digital Stereotaxic, with no drift and smooth movements. The Digital Lab Standard keeps the custom triple-start lead screws to allow fast positioning, while maintaining consistently smooth movement. The thin cords from the sensors do not interfere with movements, allowing the arm to move freely and be set at any angle. Zeroing Function for Targeting Specific Coordinates The display of each axis can be "ZERO"ed at any location, making operation simple and straightforward. To target a specific location, start at Bregma, and reset all coordinates to zero. Move the manipulator arm to the desired point and lower the electrode, probe, or micropipette into place. Memory Target coordinates can be programmed into the memory of the 51900 and 51903 Digital Lab Standard Stereotaxics. Versatility of Positioning The universal joint allows the investigator to angle the probe in either the anterior-posterior or the lateral-medial planes. The improved locking mechanism on the Lab Standard Stereotaxic Instruments will hold any angled position without slippage. Of course, it also provides an absolute lock at the vertical position. The manipulator arm may be swiveled out of the way for convenience in installing the animal or performing a procedure, then returned to the same point reliably with the aid of the locking face block above the swivel joint. Sterotaxic Small Animal System Breather is specifically designed for use with rats. Integrates easily with standard stereotaxic equipment. Incorporates adjustable nose bridge, lower jaw support and ear bars. Includes heating elements for maintaining animal temperature during procedures. System includes: EZ-150C Classic vaporizer unit EZ-107 Rat Stereotaxic non-re-breathing unit EZ-178 Mouse/Rat Sure-Seal Induction Chamber EX-211 Mouse / Rat Thin-Line stainless steel heated surgical waterbed (10"Lx3.5"Wx1"H) EZ-163 Induction Chamber warmer EZ-200 Water Heating circulation pump EZ-258 Charcoal Filters (8) O2 Regulator- specify which Oxygen Regulator is required. EZ-320 Industrial CGA540, EZ-330 medical yoke fitting Mouse / Rat nosecones, nosecone plugs, charcoal filter stand and all connecting tubes.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/CSCVAMC/WJBDDVAMC/VA24714Q1094/listing.html)
 
Place of Performance
Address: DORN VAMC;6439 GARNERS FERRY ROAD;COLUMBIA, SC 29209
Zip Code: 29209
 
Record
SN03423035-W 20140713/140712022856-b82436f51756a381284ddb546c67da7c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.