DOCUMENT
65 -- 580-14-3-167-0454 - Capnograph for sleep lab (Houston) - VA256-14-AP-6561 - Attachment
- Notice Date
- 7/31/2014
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- DEPARTMENT OF VETERANS AFFAIRS;ALEXANDRIA VA HEALTH CARE SYSTEM;P&C DEPARTMENT (90C);PO BOX 69004;ALEXANDRIA LA 71360-9004
- ZIP Code
- 71360-9004
- Solicitation Number
- VA25614Q1167
- Response Due
- 8/7/2014
- Archive Date
- 10/6/2014
- Point of Contact
- FELICIA LOVELADY
- E-Mail Address
-
A.LOVELADY@VA.GOV<br
- Small Business Set-Aside
- Total Small Business
- Description
- RESPSENSE CAPNOGRAPH Product Highlights Widescreen touch panel display Numerical EtCO2 and respiratory rate display MedAir EtCO2 technology 1.5 hours trending of EtCO2 and respiration rate Backlit LCD display Audible and visual alarms Data output via RS-232 port Specifications Dimensions:...................................... 200 (W) x 135 (H) x 50 (D) mm (7.9 x 5.3 x 2 inches) Weight:............................................. 800 grams (1.8 lbs) Power Data Battery charger:................................ 100 - 240 VAC, 50 - 60 Hz Power consumption:......................... 3.6 W at battery operation, 9 W with power supply Input:................................................ 12 VDC, 720mA Operation Working temperature:..................... 32 ° to 104 °F (0 ° to +40 °C ) Humidity:.......................................... 10 - 90% (non-condensing) Atmospheric pressure:...................... 645 - 795 mmHg (860 - 1060 hPa) Storage Storage temperature:........................ -4 ° to +122 °F (-20 ° to +50 °C) Humidity:.......................................... 10 - 90% (non-condensing) Atmospheric pressure:....................... Up to 4 atmospheres (83 - 3038 mmHg/110 - 405 hPa) Pump Pump flow:....................................... 75 ml/min Flow accuracy:.................................. ±15ml/min Battery Data Type:................................................. Lithium Ion internal battery, rechargeable Battery capacity:................................ Approximately 8 hours Charging time:.................................. Approximately 17 hours or 2 hours for each hour of use Capnography Measuring Data Respiration range:............................. 3 - 80 respirations/min Update frequency:............................. Once every breath (No Breath alarm after 25 seconds) Respiration accuracy:..................... 3 - 50 respirations/min ± 2 51 - 80 respirations/min ± 5 EtCO2/CO2 range:.............................. 0 - 99 mmHg, or 0 - 9.9 kPa EtCO2/CO2 accuracy:.......................... ±0.2 kPa / ±2 mmHg, +6% of reading (EtCO2/CO2 reading reaches its steady state accuracy 10 minutes after power up) Update frequency:............................. Once every breath (No Breath alarm after 25 seconds) Trend length:.................................... 1.5 hours
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AlVAMC502/AlVAMC502/VA25614Q1167/listing.html)
- Document(s)
- Attachment
- File Name: VA256-14-Q-1167 VA256-14-Q-1167_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1540681&FileName=VA256-14-Q-1167-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1540681&FileName=VA256-14-Q-1167-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-14-Q-1167 VA256-14-Q-1167_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1540681&FileName=VA256-14-Q-1167-000.docx)
- Place of Performance
- Address: MICHAEL E DEBAKEY VA MEDICAL CENTER;2002 HOLCOMBE BLVD;SLEEP LAB 6C-344;HOUSTON, TX
- Zip Code: 77030
- Zip Code: 77030
- Record
- SN03444678-W 20140802/140731235319-8ea6cdf27d33d6ca69705fba1e938214 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |