Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 08, 2014 FBO #4640
MODIFICATION

65 -- X-Ray Scanner

Notice Date
8/6/2014
 
Notice Type
Modification/Amendment
 
NAICS
334517 — Irradiation Apparatus Manufacturing
 
Contracting Office
MICC Center - Yuma Proving Ground, KO Directorate of Contracting, 301 C Street BLDG 2100 RM 8, Yuma, AZ 85365-9498
 
ZIP Code
85365-9498
 
Solicitation Number
W9124R14T0168
 
Response Due
8/12/2014
 
Archive Date
10/5/2014
 
Point of Contact
Teresa Beebe, 928-328-2357
 
E-Mail Address
MICC Center - Yuma Proving Ground
(teresa.beebe@us.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Amendment 0001: This amendment is being issued to incorporate the following: CLIN 0001 shall include a quantity of 1 set of 5 to 6 foot cabling and a quantity of 1 set of a minimum of 40 foot cabling; CLIN 0005 IPU shall contain the dimensions of 14 quote mark x 17 quote mark ; and CLIN 0006 IPS shall contain the dimensions of 14 quote mark x 17. quote mark New equipment shall be compatible with existing Rhythm Acquire software versions installed on YPG equipment. Installation of equipment shall only require the user to connect the cabling and select the CRxFlex scanner in the Rhythm Acquire software menu. Station 1 - HPZ400 Workstation - CR/DR Acquire 4.1.52.0 Station 2 - HPxw4600 Workstation - CR/DR Acquire 4.1.52.0 Following connection to local outlet power (115 volts, 60 hertz), cable connection to the existing workstation (FireWire IEEE 1394), and selection of the CRxFlex scanner in the existing software, the scanner shall be fully functional. The GE CR cassettes shall be compatible with normal operation of the CRxFlex scanner: The scanner exposes, scans, erases, and reloads the CR imaging plate into the cassette when the cassette is inserted into the scanner. Imaging cassettes shall accept 14 quote mark x 17 quote mark imaging plates. Imaging cassettes shall be backed with a 0.006 quote mark integrated lead screen for backscatter protection. Integrated front screens shall be available in the following configurations: 0.010 quote mark lead 0.008 quote mark copper An open-back rigid cassette shall available to facilitate scanning CR plates which were configured with soft cassettes for inspections. The GE CR plates shall be compatible with normal operation of the CRxFlex scanner: The scanner exposes, scans, erases, and reloads the CR imaging plate into the cassette when the cassette is inserted into the scanner. CR plates shall be standard 14 quote mark x 17 quote mark imaging plates and compatible with cassettes. The following CR plates shall be available: IPU IPS IPC2 The vendor shall include phone and email based customer support during the installation. Additionally, the vendor shall provide a warranty for the equipment which is provided to YPG. The warranty length shall be a minimum of one year from date of acceptance, and guarantee equipment work properly and be free of defects caused before delivery of the system, or through normal use. The vendor warranty shall cover repair or replacement equipment in the event of a failure.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/3536f9d94d81e491832c307f4e04ab2a)
 
Place of Performance
Address: MICC Center - Yuma Proving Ground KO Directorate of Contracting, 301 C Street BLDG 2100 RM 8 Yuma AZ
Zip Code: 85365-9498
 
Record
SN03452771-W 20140808/140807022410-3536f9d94d81e491832c307f4e04ab2a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.