Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 08, 2014 FBO #4640
SOURCES SOUGHT

65 -- STL - Argon Beam

Notice Date
8/6/2014
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street;Leavenworth KS 66048
 
ZIP Code
66048
 
Solicitation Number
VA25514Q1628
 
Response Due
8/8/2014
 
Archive Date
10/7/2014
 
Point of Contact
Yvonne B Kittling
 
E-Mail Address
6-1987<br
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS DOES NOT OBLIGATE THE GOVERNMENT TO AWARD A CONTRACT OR ISSUE A SOLICITATION. This announcement is seeking information from the industry for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses. Interested parties responding to this Sources Sought Notice shall submit the following information at a minimum: (1) company name, address, point of contact with phone number, and DUNS number; (2) documentation relating to technical capability to conform to the Statement of Requirement; and (3) socio-economic status to identify business as being a SDVOSB, VOSB, SB, Woman Owned, Other than Small Business, etc. Responses to this Sources Sought Notice must be emailed to yvonne.kittling@va.gov no later than August 8, 2014, 10:00 AM EDT. Please be advised that the Government will not pay for any costs for responses and information submitted. Statement of Requirement This notice uses a Brand Name or Equal Description of the product required. This permits prospective contractors to offer products other than those specifically referenced by brand name. The Saint Louis VAMC is requesting an electrosurgical generator with argon beam coagulation reduce blood loss, procedure time and surgical smoke while performing various surgical procedures. Minimal Technical Specifications: -Must have a primary safety feature that is essential to patient safety and personnel safety to minimize any risks. -The generator must safety & warning alarms to alert the user during every surgical procedure. -Minimal risks of unintentional activation during procedures that may result in patient or staff injuries. -Must provide precise and accurate monopolar and bipolar energy used during every procedure. -Compatible with accessories such ABC Handpiece, grounding cord & Lap probe used during surgical procedures. -Pure cut mode 300 max. Blend max. 200 watts -Spray Coag of 80 watts -Pin Point coag of 120 watts -Argon Beam Coagulation of 150 watts -Bipolar coag of 70 watts -Configuration: Solid State, Isolated Output -Frequency: 461 kHz (Cut, Blend, Pin Point Coag and Bipolar), 420 kHz (Spray Coag), 570 kHz -RF Isolation: <150mA per IEC 60601-2-2 -Input: 115V ( ± 10% at 60Hz 12.5A), 230V ( ± 10% at 50Hz 6.25A), 100V ( ± 10% at 50/60Hz 15A) -Cooling: Convection (No fan) -Dimensions: Less than 25"Wx30"Dx45"H, Less than 125 lbs without cylinders -Gas flow: 0.1-10.0 SLPM System 7550 (1 EA) Argon Gas Cylinder (1 EA) ABC Footswitch (1 EA) Footswitch, Bipolar, Omnidirectional (1 EA) Footswitch, Monopolar, Low Profile (1 EA)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25514Q1628/listing.html)
 
Place of Performance
Address: Department of Veterans Affairs;St Louis VAMC, John Cochran;915 N Grand Blvd, BLDG 1;Saint Louis, MO 63106-1621
Zip Code: 63106-1621
 
Record
SN03454453-W 20140808/140807023046-166d9734b1e0bcf97af01fd06f316c02 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.