SOLICITATION NOTICE

61 -- Purchase and Install 25 kW Generator - Request for Quote Response Sheet

Notice Date
8/11/2014
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335312 — Motor and Generator Manufacturing
 
Contracting Office
Department of the Air Force, Air Mobility Command, 6th Contracting Squadron, 2610 Pink Flamingo Ave, MacDill AFB, Florida, 33621-5119, United States
 
ZIP Code
33621-5119
 
Solicitation Number
F2V3034210AW02
 
Archive Date
9/5/2014
 
Point of Contact
CHRISTOPHER D. TUCK, Phone: 863-452-4175
 
E-Mail Address
christopher.tuck.3@us.af.mil
(christopher.tuck.3@us.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Request for Quote Response Sheet The contractor shall furnish all labor, tools, equipment, materials, transportation, permits and other necessary items, and services to purchase, deliver, and install a Cummings/Onan Model C25/D6, 25 Kilowatt, 60 hertz, emergency back-up diesel generator, or equivalent, and 4-pole auto-transfer switch (ATS) on the existing concrete equipment pad located at buildings 1058 and 1059 on Avon Park Air Force Range, Florida 33825. Installation shall meet all industry, Air Force, Engineering Technical Letter (ETL), Uniformed Facility Code (UFC) and National Electric Code (NEC) standards and codes for this type of generator purchase and install. The contractor shall remove existing fused generator disconnect switch and Ronk Manual Transfer Switch (MTS) located outside Bldg. 1058, replace fused commercial power Main Disconnect Switch with "breaker" Main Disconnect Switch of comparable amperage. The new ATS through the Main Lug Only (MLO) panel will supply power to B1058 Panel "A" inside building. B1059 power is supplied by Panel "A" Main Distribution Panel (MDP). Install a 200 amp ATS outside Bldg. 1058 - South Conventional Range Charlie Center Tower Control House next to disconnect. Replace existing cable trough (8"X8"X8') with a weather proof cable trough of same size. Mount all switches and disconnects on a new rack structure to properly support all newly installed equipment. Make all required connections to new generator. Ensure generator and fuel tank is properly grounded. Fuel tank shall be 150 Gallon or equal 72 hour run time, double wall UL42, skid mounted below the generator. Enclosure shall be a full weather enclosure that includes an acoustic attenuator. The contractor shall provide service and maintenance manuals of all equipment, generator, diesel fuel tank and auto-transfer switch prior to installation. Perform vibraground or equivalent testing to verify grounding system. Install all required warning signs on generator and diesel tank. Label auto-transfer switch with required signage. Provide manufacturer's warranties, subcontractor provided warranties, manufacturer's drawings, shop drawings, and as-builts, as applicable. Contractor shall follow manufacturer's recommendations for the installation of the generator, Automatic Transfer Switch, and all other components associated with this requirement. Contractor is responsible to perform the manufacturer's full start-up procedure IAW the manufacturer's start-up checklist to include load testing (110%) during initial generator startup and checkout. Conduct site clean-up and restore all areas disturbed during the construction process to preconstruction condition, including but not limited to site cleanup, backfill, grading as necessary, seeding, mulching, etc. The following Federal Acquisition Regulation (FAR), provisions and clauses apply to this solicitation and are incorporated by reference (provisions and clauses may be obtained via the internet: http://farsite.hill.af.mil, http://www.arnet.gov/far/, or http://safaq.hq.af.mil/contracting ): FAR 52.204-99, System for Award Management Registration; FAR 52.211-6, Contract Terms and Conditions; FAR 52.225-13, Restrictions on Certain Foreign Purchases; FAR 52.247-34, F.O.B. Destination. The following FAR clauses apply to this solicitation and will be incorporated in full text in subsequent award: FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders-Commercial Items, within FAR 52.212-5, the following clauses apply: Post-Award Small Business Program Representation; FAR 52.222-3, Convict Labor; FAR 52.222-19, Child Labor-Cooperation with Authorities and Remedies; FAR 52.222-21, Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity; FAR 52.222-36, Affirmative Action for Workers with Disabilities; FAR 52.225-13, Restrictions on Certain Foreign Purchases; FAR 52.232-33, Payment By Electronic Funds Transfer-Central Contractor Registration. FAR 52.252-2, Clauses Incorporated by Reference. DFARS 252.204-7003, Control of government personnel work product; DFARS 252-204-7004 Alt A, Required Central Contractor Registration (52.204-7) Alternate A, DFARS 252.232-7010, Levies on Contract Payments; DFARS 252.243-7001, Pricing of contract modifications. DFARS 252.212-7000, Offeror Representations and Certifications-Commercial Items; DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items, within DFARS 252.212-7001, the following clauses apply: DFARS 252.203-7000, Requirements Relating to Compensation of Former DoD Officials; DFARS 252.225-7001, Buy American Act and Balance of Payment Program; DFARS 252.225-7036, Buy American Act--Free Trade Agreements--Balance of Payments Program; DFARS 252.232-7003, Electronic Submission of Payment Requests; DFARS 252.247-7023, Alt III, Notification of transportation of Supplies by Sea. 5352.201-9101 Ombudsman. As prescribed in 5301-9103, insert the following clause: OMBUDSMAN (APR 2010)(a) An ombudsman has been appointed to hear and facilitate the resolution of concerns from offerors, potential offerors, and others for this acquisition. When requested, the ombudsman will maintain strict confidentiality as to the source of the concern. The existence of the ombudsman does not affect the authority of the program manager, contracting officer, or source selection official. Further, the ombudsman does not participate in the evaluation of proposals, the source selection process, or the adjudication of protests or formal contract disputes. The ombudsman may refer the party to another official who can resolve the concern. (b) Before consulting with an ombudsman, interested parties must first address their concerns, issues, disagreements, and/or recommendations to the contracting officer for resolution. Consulting an ombudsman does not alter or postpone the timelines for any other processes (e.g., agency level bid protests, GAO bid protests, requests for debriefings, employee-employer actions, contests of OMB Circular A-76 competition performance decisions). (c) If resolution cannot be made by the contracting officer, concerned parties may contact the Center/MAJCOM ombudsmen Mr Gregory S. Oneal, HQ AMC/A7K, 402 Scott Drive, Unit 2A2 Post 2A10, Scott AFB IL 62225, (618) 229-0184, fax (618) 256-6668 email: gregory.oneal @us.af.mil. Concerns, issues, disagreements, and recommendations that cannot be resolved at the MAJCOM/DRU level, may be brought by the concerned party for further consideration to the Air Force ombudsman, Associate Deputy Assistant Secretary (ADAS) (Contracting), SAF/AQC, 1060 Air Force Pentagon, Washington DC 20330-1060, phone number (703) 588-7004, facsimile number (703) 588-1067. (d) The ombudsman has no authority to render a decision that binds the agency. (e) Do not contact the ombudsman to request copies of the solicitation, verify offer due date, or clarify technical requirements. Such inquiries shall be directed to the Contracting Officer.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AMC/6CS/F2V3034210AW02/listing.html)
 
Place of Performance
Address: 29 SOUTH BLVD, BUILDING 1058, AVON PARK AFR, Florida, 33825, United States
Zip Code: 33825
 
Record
SN03459912-W 20140813/140811235142-fd98446c588808bda3db66aade6b6b7d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.