Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 17, 2014 FBO #4649
MODIFICATION

63 -- OPTION - Tyco Security System

Notice Date
8/15/2014
 
Notice Type
Modification/Amendment
 
Contracting Office
1830 Quartermaster Road, Fort Lee, VA 23801
 
ZIP Code
23801
 
Solicitation Number
0010561849
 
Response Due
8/18/2014
 
Archive Date
2/14/2015
 
Point of Contact
Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
 
E-Mail Address
Clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
MODIFICATION NOTICE:Bids are being solicited under solicitation number 0010561849. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation is issued as an invitation for bids (IFB), unless otherwise indicated herein.If your company can provide the product/services listed on the solicitation and comply with all of the solicitation instructions, please respond to this notice. To view the specifications, please go to www.FedBid.com and reference Buy No. 646371_02. GSA Schedule Bids Only: Sellers bidding on this opportunity MUST have the items requested on an existing GSA Schedule. The Schedule must either be in the Seller's name or the Seller must be able to document its ability to act as an agent of a partner's Schedule. Sellers must not bid more than their applicable contract ceiling price, excluding the FedBid Fee, for contract-specific items. If FedBid receives notice that, due to inclusion of the FedBid Fee, the Selected Bid's line item pricing is higher than the Selected Seller's applicable published government contract pricing, the FedBid Fee will be reduced to ensure the Selected Bid's line item pricing does not exceed the Selected Seller's applicable contract pricing. Sellers may offer Open Market items only in accordance with the approved Terms and Conditions of their respective GSA Schedule AND upon approval from the soliciting Contracting Officer. Information regarding GSA Schedules can be found at www.GSA.gov. This requirement is a [ Small Business ] set-aside and only qualified sellers may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2014-08-18 16:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Radford, VA 24143 The MICC Fort Lee requires the following items, Brand Name or Equal, to the following: Base Period of Performance: 09/15/2014 - 08/31/2015 LI 001: Tyco Security System, Building 450, Server Room Building 450 ? Server Room Install. The contractor shall: ?Install two card readers for the server room doors ?Existing open slots on the micro 5 panels in the boiler room will be used for the server room doors ?An 8 reader board will be added to the micro 5. ?Hardware will be changed on the server room doors to turn handles ?A transfer hinge will need to be used on each server room door to remove cypher lock and replace with a new door handle set. ?Embedded door strikes will be used on the server room doors. Magnasphere contacts with Rex Motions will be used on the doors for status. Building 450 ? Server Room consists of the following: ?(2) Man doors ?(1) Garage door ?(4) 360 degree motions in the center of the warehouse and 1 360 degree motion near the caged area ?(1) Wall mount motion will need to be located in the front office. approximately 250 feet of conduit will be needed for wiring and mounted to a hard ceiling Scope of Work INSTALL A BURGLAR ALARM PANEL (VISTA 128) IN THE 213 BUILDING. TWO KEYPADS WILL NEED TO BE PROVIDED FOR TWO SEPARATE GROUPS IN THIS BUILDING. THE GUARD HOUSE WILL NEED TO HAVE ACCESS TO REMOTELY DISARM THE GROUPS FROM THEIR LOCATION. WE WILL NEED TO INSTALL A MICRO 5 PANEL WITH 2 INPUT AND OUTPUT BOARDS AND CONNECT THEM TO A SWITCH AT BUILDING 213 AND BUILDING 450. THE SWITCHES WILL BE PROVIDED BY TYCO. THE NETWORK THAT HAS BEEN CREATED FOR SECURITY WILL BE USED TO COMMUNICATE BACK TO BUILDING 450. FOUR FIBER TERMINATIONS WILL BE NEEDED TO CONNECT TO THE NEW SWITCHES. WE WILL NEED TO PROVIDE TWO SOUNDERS ON THE EXTERIOR OF THE BUILDING, ONE FOR EACH GROUP. THIS WILL NEED TO BE CONNECTED TO FACILITY COMMANDER. WE WILL USE THE SERIAL DEVICES FOR THE VISTA 128. WE WILL NEED TO USE 4204 RELAYS AND ADD A POWER SUPPLY TO POWER THE MOTION DETECTORS. ***1-year maintenance services***, 1, Job; LI 002: Tyco Security System, Building 213 Building 213 Install. The contractor shall: ?Install a burglar alarm panel (vista 128) in the 213 building ?Two keypads will need to be provided for two separate groups in this building ?The guard house will need to have access to remotely disarm the groups from their location. ?Install a micro 5 panel with 2 input and output boards and connect them to a switch at building 213 and building 450. ?The network that has been created for security will be used to communicate back to building 450 ?Four fiber terminations will be needed to connect to the new switches. we will need to provide two sounders on the exterior of the building, one for each group oThis will need to be connected to facility commander ?Contractor will use the serial devices for the vista 128 ?We will need to use 4204 relays and add a power supply to power the motion detectors Building 213 consist of the following: ?(6) man doors ?(2) garage doors ?(7) 360 degree motions in the center of three sections ?Approximately 350 feet of conduit will be needed for wiring and mounted to a hard ceiling. Scope of Work INSTALL A BURGLAR ALARM PANEL (VISTA 128) IN THE 213 BUILDING. TWO KEYPADS WILL NEED TO BE PROVIDED FOR TWO SEPARATE GROUPS IN THIS BUILDING. THE GUARD HOUSE WILL NEED TO HAVE ACCESS TO REMOTELY DISARM THE GROUPS FROM THEIR LOCATION. WE WILL NEED TO INSTALL A MICRO 5 PANEL WITH 2 INPUT AND OUTPUT BOARDS AND CONNECT THEM TO A SWITCH AT BUILDING 213 AND BUILDING 450. THE SWITCHES WILL BE PROVIDED BY TYCO. THE NETWORK THAT HAS BEEN CREATED FOR SECURITY WILL BE USED TO COMMUNICATE BACK TO BUILDING 450. FOUR FIBER TERMINATIONS WILL BE NEEDED TO CONNECT TO THE NEW SWITCHES. WE WILL NEED TO PROVIDE TWO SOUNDERS ON THE EXTERIOR OF THE BUILDING, ONE FOR EACH GROUP. THIS WILL NEED TO BE CONNECTED TO FACILITY COMMANDER. WE WILL USE THE SERIAL DEVICES FOR THE VISTA 128. WE WILL NEED TO USE 4204 RELAYS AND ADD A POWER SUPPLY TO POWER THE MOTION DETECTORS. ***1-year maintenance services***, 1, Job; Option 1 Period of Performance: 09/15/2015 - 08/31/2016 LI 001: Annual Maintenance, Building 450 & 213, 1, Job; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, MICC Fort Lee intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. A Seller may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. MICC Fort Lee is taking this action in an effort to improve both seller access and awareness of requests and the agency's ability to gather multiple, completed, real-time bids.All responsible Sellers that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Sellers that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Sellers that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Sellers may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should Sellers require additional clarification, contact FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com. Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 30 calendar days after close of Buy. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. EFFECTIVE JAN 2005, all offerors are required to use ?Online Representations and Certifications Application (ORCA) to respond to federal solicitations. To register in ORCA, please go to www.bpn.gov/orca. You must be active in the Central Contractor Registration (www.ccr.gov) and have a Marketing Partner Identification Number (MPIN), to register in ORCA. Failure to register in ORCA may preclude an award being made to your company. No partial shipments are permitted unless specifically authorized at the time of award. ***Period of performance will be based off the date of the award.***
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/53f4d3d7d90f6e29aa73408dd838160a)
 
Place of Performance
Address: Radford, VA 24143
Zip Code: 24143
 
Record
SN03467986-W 20140817/140816001053-53f4d3d7d90f6e29aa73408dd838160a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.