Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 21, 2014 FBO #4653
SOLICITATION NOTICE

Z -- Cape Henry Light Station Stairway Replacement - SOW

Notice Date
8/19/2014
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238120 — Structural Steel and Precast Concrete Contractors
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), MSRT, 1260 Shotgun Road, Ste 101, Chesapeake, Virginia, 23233, United States
 
ZIP Code
23233
 
Solicitation Number
21-14-2745CVA16
 
Archive Date
9/11/2014
 
Point of Contact
Pascal Joseph, Phone: 7572952014
 
E-Mail Address
pascal.joseph@uscg.mil
(pascal.joseph@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
SOW. 1. GENERAL REQUIREMENTS: The work consist of providing all labor, materials and equipment as required to provide egress staircase and awning at Chesapeake Bay Pilot tower 583 Atlantic Ave, Fort Story, VA 23459. Contractor will ensure that they comply with attached access request procedures to access the work site. 2. COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK: Upon acceptance the contractor shall commence work NLT five (5) days after approval and shall complete work 45 days after contract is awarded. 3. SCOPE OF WORK: To include but not limited to:.1 Remove existing egress stairway, and awning as directed by the QAE Representative. Remove any old anchors in concrete block and fill iwth concrete patch, paint to match existing paint..2 Fabricate stairway and awning as close to existing dimensions as possible. The finished product must closely resemble existing stairway in order to preserve historical nature of the building. Stairway must be 23 rungs made of diamond plate steel. angle iron framing for awning must be replaced and awning must cover 2 sides and top angle down for water drainage. Platform at top of stairs must be 4 foot 8 inches by 4 foot 8 inches. the top edge of the new stairway handrail must not be more than 37 inches nor less than 36 inches from the upper surface of the stair rail to the surface of the tread. Stairway must meet current OSHA Standards..3 Install Stairway and awning using appropriate concrete anchors. Steel square tubing posts must be set in concrete. Sidewalk concrete must be patched after posts are set..4 Stairway must be hot dip glavanized and then painted white. Awning sheeting must be galvanized and also painted white..5 Contractor shall restore and portions of the building effected by work to existing conditions.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/5f90adeae5a4b000d38452ca5a477191)
 
Place of Performance
Address: CAPE HENRY LIGHT STATION W/HOUSING, Chesapeake Bay Pilot tower 583, Atlantic Ave, Fort Story, Virginia, 23459, United States
Zip Code: 23459
 
Record
SN03470081-W 20140821/140819235246-5f90adeae5a4b000d38452ca5a477191 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers