FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 28, 2014 FBO #4660
MODIFICATION

J -- WATER WELL PUMP REPAIR DUBOIS ID - ag32sds140065 mod 01

Notice Date
8/26/2014
 
Notice Type
Modification/Amendment
 
NAICS
221310 — Water Supply and Irrigation Systems
 
Contracting Office
Agricultural Research Service - Western Business Service Center
 
ZIP Code
00000
 
Solicitation Number
ag-32sd-s-14-0065
 
Archive Date
9/11/2014
 
Point of Contact
Frederick O. Gifford, Phone: 510-559-6017
 
E-Mail Address
fred.gifford@ars.usda.gov
(fred.gifford@ars.usda.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
ag32sds140065 Mod 1 Our SOW will be changed as follows and interested firms are to present their proposal per the below and included. 01 Pump brand make model, Voltage, efficiency rating and HP with turnkey installation when connected to the generator which includes all check valves and all other for turnkey installationtiny $__________ 02 We would like a timer on the generator so that we can have it auto shut off after a period of time instead of letting the generator run out of fuel. $_________________ • 2" pipe will not be needed • The contractor will need supply the panel to control the pump. It will be installed at the well location with 20ft chord to plug into the generator. The generator will be mounted in a trailer. • USSES will install the wooden post for the panel to be attached. The post will be about railroad tie size. • The generator is NOT 3 phase (in case someone asks) • There needs to be a bleed out valve at about 10 ft into the well for winterizing so it does not freeze. • There needs to be three check valves in the well. • There needs to be one check valve outside the well on the line that goes to the tank to keep the water from back flowing at a faucet on the line by the well. • There needs to be a motor saver/low current indicator to shut off the pump. • No sensor and float in the tank to shut off the pump. That will either require power or sensors and solar panels for power at the tank etc., and it was getting to complicated. Having a timer and motor saver/low current indicator shut off will be how we will shut off the well when no one is there. Option We would like a timer on the generator so that we can have it auto shut off after a period of time instead of letting in run out of fuel. By using the original pipe, the pump jack went 693 feet. We would want the new pump put at that level because we know that we have the pipe to reach that level and we know that there is water even though the static is ~500. The generator for the well is a Generac GP15000E 15,000 watt electric start portable generator. It will be mounted on a trailer for hauling out to the well site.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/53d4031e18a27c86cccc4472d16605e2)
 
Place of Performance
Address: USDA ARS, 19 Office Loop, Dubois, Idaho, 83423, United States
Zip Code: 83423
 
Record
SN03480489-W 20140828/140826234911-53d4031e18a27c86cccc4472d16605e2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.