MODIFICATION
J -- Provo Area Office Building Maintenance
- Notice Date
- 8/29/2014
- Notice Type
- Modification/Amendment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Bureau of ReclamationUpper Colorado RegionRegional Office125 South State Street, Room 8100Salt Lake CityUT84138US
- ZIP Code
- 00000
- Solicitation Number
- R14PS00977
- Response Due
- 9/8/2014
- Archive Date
- 10/8/2014
- Point of Contact
- Lisa Hilton
- E-Mail Address
-
lhilton@usbr.gov
(lhilton@usbr.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- The U.S. Bureau of Reclamation, Upper Colorado Region has a requirement for building maintenance for the Provo Area Office. This requirement is being procured in accordance with Parts 12 and 13 of the Federal Acquisition Regulations as a 100% small business set aside. The Bureau of Reclamation intends to issue a competitive solicitation for this requirement. PROJECT DESCRIPTION: Building Maintenance for a Base plus three option years. The contractor shall provide the time, manpower, tools and expertise necessary to maintain the heating, cooling, electrical and lighting components throughout the interior and exterior of the PAO. The 57,000 square foot building is comprised of an open-design office area containing private offices and cubicle clusters, a cluster of warehouse bays (4), a materials lab and a front and rear parking area. The building is heated by two Cleaver Brooks boilers that supply heated water based solution to 53 VAV boxes located in the ceiling throughout the building. The building is cooled by a York chiller system that supplies chilled water to five air handler rooms throughout the building. Control of the heating and cooling system is through a new Alerton Direct Digital Control (DDC) system. The VAVs, Air Handler Rooms and Boiler Room have been retrofitted with new controls for the valves and motors that are controlled by the DDC system. The electrical motors for the supply and return air fans have been retrofitted with new high efficiency motors and Variable Frequency Drives. The circulation pumps for the heated and chiller water in the boiler rooms have been retrofitted with new high efficiency motors and Variable Frequency Drives. Control of the building heating and cooling system is through a central standalone computer. The building has also been fitted recently with ceiling fans that are also controlled by the Alerton control system. The fans destratify the air in the higher portions of the buildings ceiling. The contractor shall maintain the interior of the building temperature between 68-72 F. The building lighting is managed by a Leviton computer control system. The full requirements will be included in the performance work statement included with the solicitation. The period of performance is as follows: Base Year: October 1, 2014 through June 30, 2015 Option Year 1: July 1, 2015 through June 30, 2016 Option Year 2: July 1, 2016 through June 30, 2017 Option Year 3: July 1, 2017 through June 30, 2018 NAICS AND SIZE STANDARD: The NAICS code for this project is 238220 with a small business size standard of $15 million SOLICITATION RELEASE DATE: The release date for the final and formal solicitation number R14PS00977 is anticipated in August or September 2014. Interested parties are encouraged to monitor this announcement for updates and the release of the solicitation documents. The solicitation documents for this procurement will be accessible from the Federal Business Opportunities (FBO) website, www.fbo.gov. It is, and will continue to be, all potential offeror's responsibility to monitor the FBO website for any amendments, updates, responses to questions and answers. SYSTEM FOR AWARD MANAGEMENT (SAM, www.sam.gov): The System for Award Management (SAM) is a recently implemented Federal Government owned-and-operated FREE web site that consolidates the capabilities in Central Contractor Registration (CCR)/Federal Register (FedReg), Online Representations and Certifications Application (ORCA), and Excluded Parties List System (EPLS). Offerors must be successfully registered in SAM in order to be considered for a Government contract award. If you had an active record in CCR, you have an active record in SAM. POINT-OF-CONTACT FOR QUESTIONS: The contract specialist for this solicitation is Lisa Hilton, phone number 801-524-3808, email: lhilton@usbr.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/d42b4920fb03e40f13b23ed4377d0246)
- Record
- SN03488857-W 20140831/140829234900-d42b4920fb03e40f13b23ed4377d0246 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |