SOLICITATION NOTICE
C -- IDC CONTRACT A-E SERVICES FOR CONSTRUCTION PHASE SERVICES IN SUPPORT OF VARIOUS MILITARY, CIVIL WORKS, AND INTERNATIONAL AND INTERAGENCY SERVICES (IIS) PROJECTS WITHIN SOUTHWESTERN DIVISION (SWD) BOUNDARIES
- Notice Date
- 8/29/2014
- Notice Type
- Presolicitation
- Contracting Office
- USACE District, Tulsa, ATTN: CESWT-CT, 1645 South 101st East Avenue, Tulsa, OK 74128-4609
- ZIP Code
- 74128-4609
- Solicitation Number
- W912BV-14-R-0085
- Response Due
- 9/30/2014
- Archive Date
- 10/30/2014
- Point of Contact
- Diane Cianci, 918-669-7458
- E-Mail Address
-
USACE District, Tulsa
(diane.cianci@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- 1. CONTRACT INFORMATION: General: This A-E Services Contract is being procured in accordance with the Brooks Act (Public Law PL 582) and implemented in the Federal Acquisition Regulation (FAR) Subpart 36. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. This announcement is set-aside as quote mark Small Business quote mark under NAICS code 541330, engineering services. The contract is anticipated to be awarded in November 2014. It is anticipated that two contracts will be awarded from this announcement for an estimated total amount of $4,900,000 each and will have a 3-year base period and one two (2) year option period. A Minimum Guarantee amount of $2,000 will apply to the Base Period only. The contract awarded under this announcement will be administered by the Tulsa District and the Tulsa District may elect to transfer capacity to other USACE Districts in support of assigned programs. a. Contract Award Procedure: Before a business is proposed as a potential contractor, they must be registered in the System for Award Management (SAM) database. Register via the SAM internet site at http://www.sam.gov. The Service Contract Act will apply to this acquisition. The proposed services will be obtained by a Negotiated Firm-Fixed Price Contract. b. Nature of Work: The services necessary for each requirement will be negotiated and awarded as individual Task Orders. The A-E shall furnish all services, materials, supplies, and supervision required to fully complete each Task Order. c. Place of Performance: Projects are anticipated to be primarily in support of the U.S. Army Corps of Engineers Southwestern (SWD) Boundaries. d. Contractor Manpower Reporting: The contractor will be required to report all contractor labor hours (including subconsultant labor hours) required for performance of services provided under this contract via a secure data collection site with the exception of civil works funded task orders. The contractor will be required to completely fill in all required data fields using the following web address: http://www.ecmra.mil/. Reporting inputs will be for the labor executed during the period of performance during each Government fiscal year (FY), which runs from October 1 through September 30. While inputs may be reported any time during the FY, all data shall be reported no later than October 31 of each calendar year. 2. PROJECT INFORMATION: The following work may be expected under this contract: General required services consist of qualified, experienced firms capable of providing the full spectrum of construction phase A-E services. The contractor must have extensive knowledge of all pertinent local building codes to include, but not necessarily limited to, the International Building Code, International Mechanical Code, National Electric Code, Leadership in Energy and Environmental Design, etc. The contractor must also have extensive knowledge of the USACE three phase inspection system as well as WINRMS. The contractor shall demonstrate the capability to execute multiple concurrent task orders for construction phase A-E services including, but not limited to, providing a series of qualified construction, engineering, and safety professionals to participate as members of the USACE onsite contract administration teams at various locations (as many as 25 professionals may be required at any given time for extended periods of time of 12 months or more). The required services will include, but may not necessarily be limited to, onsite review of contractor submitted shop drawings and submittals for conformance with the approved plans and specifications, daily onsite evaluation of construction methods and materials, onsite interpretation of plans and specifications, daily evaluation of jobsite safety, onsite evaluation of construction progress, and daily onsite evaluation of construction for conformance with applicable building codes. 3. SELECTION CRITERIA: The selection criteria for this acquisition are listed in descending order of importance (first by major criterion and then by each sub-criterion), Criteria: (a)-(e) are primary criteria; items (f) and (g) are secondary and are used as a tie-breakers among technically qualified firms. The selection criteria in descending order of importance are:. (a) Specialized Experience and Technical Competence: (Ensure that all special experience requirements are reflected on appropriate personnel resumes at Section E, Part I, SF 330) (1) The selected team must demonstrate recent experience (within the past 5 years) and significant experience in performing work on a wide variety of sites located within the Southwestern Division (SWD) Boundaries in a manner that complies with Federal, State, and Local laws and regulations, and within the timeframe required. It is anticipated that multiple task orders may be awarded simultaneously to the selected firm. Firms must document specialized experience and technical competence in the construction phase services area, and have extensive knowledge of all pertinent local building codes to include but not necessarily limited to the International Building Code, International Mechanical Code, National Electric Code, Leadership in Energy and Environmental Design, etc... The contractor must also have extensive knowledge of the USACE three phase inspection system as well as WINRMS. The contractor shall demonstrate the capability to execute multiple concurrent task orders for construction phase A-E services including but not limited to: providing a series of qualified construction, engineering, and safety professionals to participate as members of the USACE onsite contract administration teams (as many as 25 professionals may be required at any given time for extended periods of time up to 12 months). The required services will include but may not necessarily be limited to onsite review of contractor submitted shop drawings and submittals for conformance with the approved plans and specifications, daily onsite evaluation of construction methods and materials, onsite interpretation of plans and specifications, daily evaluation of jobsite safety, onsite evaluation of construction progress, and daily onsite evaluation of construction for conformance with applicable building codes. (b) Professional Qualifications: The criteria will include a review of proposed personnel, in the following disciplines: (either in-house or through consultant) and disciplines with registration where applicable: Project Management, Construction Management, Building Code Experts, Safety Professionals, Security Specialists, Architecture, Mechanical, Fire Protection, Commissioning, Civil, Structural, Cost Estimating, Geotechnical, Surveying, and Interior Design. Particular focus will be on the qualifications of per sonnel with knowledge of national, state, and local codes for the Arkansas, Oklahoma, Kansas, and Texas areas. (c) Past Performance: Include performance on Department of Defense (DoD) and other contracts in terms of quality of work, compliance with delivery schedules, history of working relationships with consultants, timely construction and technical support and overall cooperativeness and responsiveness. (d) Capacity: The criteria to provide personnel on numerous construction contracts that are administered by the Corps of Engineers. Anticipate number of personnel needed could range from 10 to 25 at any given time, depending on the workload, and typical duration of construction contracts administered by the Tulsa District range from six (6) months to three (3) years. The selected contractor shall also have Engineers available as needed to provide services to the U.S Army Corps of Engineers, Southwestern Division during peak workloads and / or during deployment of Government personnel in support of the Overseas Contingency Operations (OCO) or during deployment of Government personnel in support of domestic national needs to include, but not necessarily limited to, hurricane recovery, floods, ice storms, and tornado recovery; services may be required with as little as 7 calendar days advance notice. Time duration of personnel usage will range from one (1) month to one (1) year or longer as needed, depending on the workload requirements of the Southwestern Division. The criteria will include a review of project specific narrative indicating the extent to which the A-E firm has provided the specified construction support and their proven ability to work on multiple large scale design projects. (e) Knowledge of Locality. (Principally the area covered by the Southwestern Division (SWD). Firm must demonstrate specialized experience with respect to local construction methods and climatic conditions. (f). Volume of DoD contracts: for construction phase services awards in the past twelve (12) months. (g). Small Business Participation. The extent of partici pation of Small Businesses and other Socio-Economically Disadvantaged Small Businesses or Entities will be measured as a percentage of the total anticipated contract effort regardless of whether the Small Business or other Socio-Economically Disadvantaged Small Business or Entity is a prime contractor, subcontractor, or joint venture part ner. 4. SUBMISSION REQUIREMENTS: Submittals should be sent to U.S. Army Corps of Engineers, Attn: Ms. Diane Cianci, 1645 S. 1645 S. 101st East Avenue, CECT-SWT-E, Tulsa, OK 74128-4609, no later than 2:00 p.m. on 30 September 2014. (a) Interested firms having the capabilities and qualifications to perform this work must submit one copy of SF 330 (6/2004 Edition) including Parts I and II as described herein and one CD-ROM of the SF 330 submittal, to the above address not later than 2:00 p.m. (Central Time) on the response date as above. The date and time are strictly enforced and late packages will not be considered. Late proposal rules found in FAR 15.208 will be followed for late submittals. So-licitation packages are not provided. The SF 330 should be complete and specifically address the requirements of this announcement. Functions to be subcontracted shall be clearly identified by subcontractor or entity and their office location (specify the address of the office and key person that is assigned there). (b) Responding firms must submit a copy of the originally signed, or current (signed within the past 12 months), and accurate SF 330, Part II for the specific prime other offices of the prime, and subcontractor offices proposed to perform the work even if an SF 330, Part II is already on file. SF 330, Part II shall be provided for the specific prime, other offices of the prime, and sub-contractor offices proposed to perform the work. All Part IIs MUST be signed with original sig-nature or facsimile of the original signature (signed within the past 3 years is required) and dated. A copy of a signed/dated Part II is acceptable. Although firms are encouraged to update their SF 330 Part II at least annually, older ones (up to 3 years old in accordance with FAR 36.603(d)(5)) will still be considered by the board. However, a firm may be recommended as not qualified or ranked low if missing, confusing, conflicting, obsolete or obscure information prevents a board from reasonably determining that a firm demonstrates certain required qualifications. Indicate in Block 5b of each Part II if the firm is a Large Business, Small Business, HubZone, Service Disabled Veteran-Owned Small Business, or Woman-Owned Small Business. To be classified as a small business, a firm's average annual receipts or sales for the preceding three fiscal years must not exceed $15 million. (c) Submit only one SF 330, Part I from the Prime for the design team, completed in accordance with the SF 330 instructions and additional instructions herein. It must contain information in sufficient detail to identify the team (prime, other offices of the prime, and consultants) proposed for the contract. The A-E shall not include company literature with the SF 330. (d) In block No. 4 Part II provide the Data Universal Numbering System (DUNS) number issued by Dun and Bradstreet Information System (1/866-705-5711) for the prime A-E or Joint Venture. The DUNS number must be for the firm or joint venture performing the work (i.e. not the parent DUNS number, but a DUNS number specifically for the office performing the work. (e) In Section C of the SF 330, Part I, identify the discipline/service to be supplied by the Prime, Prime Branch offices as applicable, and each consultant. Provide brief resumes in Section E of the on-staff or consultant employees you intend to use to perform the work. Resumes must be submitted for each employee required to meet the minimums stated above in paragraph 3b. Resumes shall not exceed one page. (f) In Section F, a maximum of 10 projects for the total proposed Team (including the prime and consultants) shall be provided. Use no more than one page per project. (g) In Section G, block 26, along with the name; include the firm and office location the person is associated with. The names of all individuals included in the resumes in Section E shall be listed in Block G-26 along with their firm location and their roles even if example project experience in Block G-28 is not applicable. Also include Team Project Organization Chart in Part I, Section D indicating how each firm on the proposed team (prime, applicable prime branch offices, and each subcontractor as identified in Part I, Section C) integrates into the composite team. (h) In Section H, of the SF 330, Part I, provide a narrative to address each of the requirements, including subparagraphs, of items listed in Section 3, Selection Criteria, of this announcement. ) In Section H, Part I, SF 330, firms must show their last three (3) years of DoD contract awards stated in dollars (see 3(e) above), provide an itemized summary of DoD awards to include Agency Contract Number/Task Order No. DoD awards shall be shown in an itemized summary including Agency, Contract Number/Task Order No., Project Title, and Award Amount dollars. Include a total of all listed awards. Note that award of Indefinite Delivery Contracts should not be counted as award amounts; only actual Task Orders and any modifications thereto should be included in the amounts. In addressing Team capabilities, clarify planned capability, existing capability, and prior experiences, if any. Include any other relevant information including a short discussion of why the firm is especially qualified based upon the specific selection criteria listed in Section 3. (i) In Section H, Part I, SF 330 Generally, describe the firm's Quality Management Plan (QMP). A project-specific detailed QMP must be prepared and approved by the Government as a con-dition of contract award, but is not required with this submission. Indicate the estimated per-centage involvement of each firm on the proposed team. Do not exceed twenty pages for Sec-tion H. Front and back side use of a single page will count as 2 pages, and print type used in charts, graphics, figures and tables may be smaller than 11 font but must be clearly legi-ble. For any of the text, do not go smaller than 11 point font. Pages in excess of the maximums list will be discarded and not used in evaluation of the selection criteria. Foldouts are not allowed and shall not be considered. (j) Personal visits to discuss this announcement will NOT be entertained. (k) Solicitation packages are not provided for A-E contracts and no additional project information will be given to firms during the announcement period. Facsimile transmissions will not be accepted. Points of Contact: Contracting - Diane Cianci (918) 669-7458. This is not a request for proposal. In accordance with FAR clause 52.219-14 Limitations on Subcontracting for services, quote mark At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. quote mark INQUIRIES - OFFEROR'S QUESTIONS AND COMMENTS USE OF BIDDER'S INQUIRY 29 August 2014 Prospective offerors should submit questions and inquiries related to this solicitation in accord-ance with the following (collect calls will not be accepted): a. For information related to amendments, and the dates set for receipt of proposals, please check http://www.fedbizopps.gov b. Contractual and Technical inquiries and questions relating to proposal procedures are to be submitted via Bidder Inquiry in ProjNet at https://www.projnet.org/projnet. 1. To submit and review bid inquiry items, offerors will need to be a current registered user or self-register into the system. To self-register go to the aforementioned web page and click on the BID tab. Select Bidder Inquiry, select agency USACE, and enter the Bidder Inquiry Key for this solicitation listed below, your e-mail address, and then click login. Fill in all required information and click create user. Verify that information on next screen is correct and click continue. 2. From this page you may view all bidder inquiries or add an inquiry. 3. Bidders will receive an acknowledgement of their question via e-mail, followed by an answer to their question after it has been processed. 4. The Solicitation Numbers are: W912BV-14-R-0085 (Small Business Set Aside) The Bidder Inquiry Key is:X7W8QX-FTSZWJ 5. Address/enter only one question/issue per entry. c. The Bidder Inquiry System will be unavailable for new inquiries 4:00pm (Central) five (5) days before proposal are due in order to ensure adequate time is allotted to form an appro-priate response and amend the solicitation, if necessary. d. Offerors are requested to review the specification in its entirety, and review the Bidder Inquiry System for answers to questions prior to submission of a new inquiry. e. The call center operates weekdays from 8AM to 5PM U.S. Central Time Zone (Chicago). The telephone number for the Call Center is 800-428-HELP. f. Offers will NOT be publicly opened. Information concerning the status of the evaluation and/or award will NOT be available after receipt of proposals. g. The point of contact for this solicitation is: Contract Specialist: Diane Cianci Telephone:918-669-7458 E-MAIL: diane.m.cianci.civ@mail.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA56/W912BV-14-R-0085/listing.html)
- Place of Performance
- Address: USACE District, Tulsa ATTN: CECT-SWT-E, 1645 South 101st East Avenue Tulsa OK
- Zip Code: 74128-4609
- Zip Code: 74128-4609
- Record
- SN03489613-W 20140831/140829235843-7b80ab914aadbd1812531ff8466a281d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |