66 -- Climate Controlled Chamber

Notice Date
9/2/2014
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Agricultural Research Service - Eastern Business Service Center
 
ZIP Code
00000
 
Solicitation Number
AG-32SC-S-14-703491
 
Archive Date
9/23/2014
 
Point of Contact
Kristen Turner, Phone: 3096816624
 
E-Mail Address
kristen.turner@ars.usda.gov
(kristen.turner@ars.usda.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
The following minimum requirements are added in this modification: • Three compartment walk-in chamber with total dimensions 25'x11'x8'. • Temperature control between 67°F-72°F including temperature alarm. • Required capability: temperature settings between 67°F-72°F must be maintained independently between the 3 rooms. • Humidity of chambers must be maintained within the range of 40%-70% humidity. • Central room of the chamber will be a work room with temperature regulated by air conditioner. This air conditioner will be a dedicated cooling system for this chamber, not the building HVAC system. • Work room will be furnished by the contractor with a sink with domestic water piping and drain. • Two plant growth rooms will be accessed from doors on either side of the central work room. • Plant growth rooms will be used to rear colonies of plant-feeding insects on a range of plants. • Chilled water system will be used to regulate temperature of plant growth rooms - Cornell chilled water source is 39°F. • Electrical wiring for a total of (8) 120v receptacles in each of the three rooms, to power 16-20 fluorescent light fixtures (fixtures NOT included by contractor, will be supplied by end user). • Estimated heat load from lighting and growth room equipment is 4500 BTU/hr. • Work room lighting will be provided by overhead fluorescent lamps and desk lamps (fixtures NOT included by contractor, will be supplied by end user). • Vacuum pump (10 CFM capacity) with variable power supply serving each of the three rooms. • Preassembly and testing not required. A freight elevator exists to bring the components of the chamber down one level to the basement site. Chamber will be assembled on site. • Remote monitoring of controls NOT required. • Electrical subpanels for running 120 VAC power are on site - subpanel installation NOT required. • Electrical specifications of the site: 115vac/120vac single phase/60Hz. • Local environmental conditions: Over the course of a year, the temperature typically varies from 16°F to 81°F and is rarely below -0°F or above 90°F. Average annual temperature is 46°F. The relative humidity typically ranges from 47% to 95% over the course of the year, rarely dropping below 28% and reaching as high as 100%.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/8b8e50cd8512cbd1bac8a2eda8054d59)
 
Place of Performance
Address: USDA, ARS, Robert Holley Center, Ithaca, New York, 14853-2901, United States
Zip Code: 14853-2901
 
Record
SN03491995-W 20140904/140902235605-8b8e50cd8512cbd1bac8a2eda8054d59 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.