Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 04, 2014 FBO #4667
DOCUMENT

66 -- 9 Channel Programmable Stimulator - Attachment

Notice Date
9/2/2014
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;VISN 7 Network Contracting Activity;501 Greene Street;Hatcher Building - Suite 2;Augusta GA 30901
 
ZIP Code
30901
 
Solicitation Number
VA24714I1569
 
Response Due
9/4/2014
 
Archive Date
10/4/2014
 
Point of Contact
Kevin Warren
 
E-Mail Address
3-0188
 
Small Business Set-Aside
N/A
 
Description
Sources Sought: Master 9 - 9 channel Stimulator with repetitive, single and train outputs. Includes Monophasic and biphasic pulses and ramp outputs. Records patterns and deliver recorded patterns. Channel 9 can record input patterns (such as action potential, sine wave, etc.). The pattern is saved in the memory of the Master-9 even after disconnecting the source. This recorded pattern can now be delivered in all the modes of operation: FREE-RUN, TRIG, TRAIN, and TWIN modes. The user can save 9 independent recorded patterns, one for each paradigm. Use some channels to stimulate your preparation, while using other channels to trigger other instruments (oscilloscope, PC, etc.) in synchronization with the stimulation. All channels can be operated independently, or synchronized to produce complex paradigms (e.g. Theta-Burst). Modification on-the-fly: modify parameters without stopping the stimulation. For example, while stimulating, switch the stimulation rate from one range to another (e.g. from 98 PPS to 102 PPS). Wide time intervals between pulses/trains: From 40 Microsec to 3,999 sec. ?V Voltage steps. Each channel can deliver ?V voltage steps, even for biphasic pulses. Simple switch-off stimulation, programmed via a PC. As a stand-alone unit: All parameters are set by the front panel touch screen. You can easily switch between 9 stored independent experiments. Each experiment uses all channels. When connected to a PC (via a USB interface): Upload and download new experiments. Control and modify Master-9 parameters from a PC in accordance with experiment feedback. Scheduler: Use the powerful scheduler to modify parameters and switch between experiments at scheduled times. Operating Modes Each Master-9 channel can operate in any of the following modes: Free-Run: The channel delivers repetitive pulses. Trig: Single pulse after triggering (manually, internally from other channels, or externally). Twin: Twin pulses after triggering. Train: Train of pulses after triggering. DC: The channel delivers a DC output independent of time settings. Gate: Each time that an input signal is applied, the channel delivers repetitive pulses. Whenever the input signal stops, the channel stops operating. Inter-Channel Connections Each channel can be internally connected to any other channel with no need to connect wires between channels. Each channel can be internally connected to multiple channels simultaneously. Parameters Each channel operates within the following ranges: ParameterMINMAX Number of Pulses per Train 1 60,000 Pulse Duration 5 ?sec 3,999 sec Delay Time 5 ?sec 3,999 sec Interval Time (1/rate) 40 ?sec 3,999 sec Voltage Range Each channel delivers output pulses with amplitudes ranging from -10V to +10V, and with a maximum current of 20mA. Combined Pulses Three additional outputs deliver programmable combinations of pulses. Two Additional Clocks In addition to its standard 8 channels, Master-9 features 2 internal clocks: The first clock counts the time in seconds up to 24 hours and is used to measure the time elapsed from an event (for example, the beginning of the experiment). The second clock counts the time in tenths of a second up to 1 hour and is used to measure intermediate times. AC Power 110/230 Volt, 50/60 Hz. Rack Mounting Master-9 can be mounted on a standard 19-inch rack.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AuVAMC/VAMCCO80220/VA24714I1569/listing.html)
 
Document(s)
Attachment
 
File Name: VA247-14-I-1569 VA247-14-I-1569.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1608197&FileName=VA247-14-I-1569-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1608197&FileName=VA247-14-I-1569-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Ralph H. Johnson Medical Center;325 Folly Road, Suite 300;Charleston, SC
Zip Code: 29412
 
Record
SN03492310-W 20140904/140902235938-8563b7c40d37ae3ccfc23e62802fa8fe (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.