AWARD
N -- Add spray foam insulation and fire coating to buildings 417 and 506 in Alpena
- Notice Date
- 10/7/2014
- Notice Type
- Award Notice
- NAICS
- 238310
— Drywall and Insulation Contractors
- Contracting Office
- CRTC-Alpena/MSC Office, Michigan Air National Guard, 5884 A Street, Alpena, MI 49707-8125
- ZIP Code
- 49707-8125
- Solicitation Number
- W912JB-14-T-8010
- Response Due
- 9/12/2014
- Archive Date
- 11/6/2014
- Point of Contact
- Jonathan Bodus, 269-969-3363
- E-Mail Address
-
CRTC-Alpena/MSC Office
(jonathan.bodus@ang.af.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W912JB-14-P-8016
- Award Date
- 9/19/2014
- Awardee
- BUILDING EXPRESS, INC. (969952829) <br> 4170 US HWY 23 S <br> ALPENA, MI 49707-5138
- Award Amount
- $49,649.90
- Line Number
- 0001
- Description
- Service non-personal: Contactor shall provide all materials, labor, transportation and supervision necessary to install spray foam insulation in buildings 417 and 506 located at the Alpena Combat Readiness Training Center, Alpena, MI. All work shall be performed in accordance with the performance standards below: Building 417: - Install 4,600 square feet of R-36 spray closed cell foam insulation at 5 quote mark thick average to the building ceiling over the existing ceiling panels. The foam shall be a two component, closed-cell, spray applied rigid polyurethane foam system. The product shall use recycled plastic materials and have a zero ozone depleting potential. The insulation shall be Heatlok Soy 200 Plus or equal in physical ASTM test properties and fire test results. The existing ceiling shall remain in place. - Include 4,600 square feet of a water-based, fire protection, intumescent coating to meet NFPA 286 requirements. The fire coating shall be Blazelok TBX or equal in physical ASTM test properties and fire test results. Building 506: -Provide spray closed cell foam insulation of R-22 value on the walls and R-40 on the ceiling. The wall area is 1,568 square feet and the ceiling area is 5,600 square feet. - Install 7,168 square feet of closed cell foam insulation. The foam shall be a two component, closed-cell, spray applied rigid polyurethane foam system. The product shall use recycled plastic materials and have a zero ozone depleting potential. The insulation shall be Heatlok Soy 200 Plus or equal in physical ASTM test properties and fire test results. - Include 7,168 square feet of a water-based, fire protection, intumescent coating to meet NFPA 286 requirements. The fire coating shall be Blazelok TBX or equal in physical ASTM test properties and fire test results. NOTE: Project is subject to the Service Contract Act. Wage Determination WD 05-2271 (Rev.-14), 08/05/2014, is in effect.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA20-3/W912JB-14-T-8010/listing.html)
- Record
- SN03544432-W 20141009/141007234358-10478a0a0951ec2821a74abd466cc7fc (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |