Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 31, 2014 FBO #4724
DOCUMENT

65 -- Radio Frequency Ablation Electrode StarBurst Xli-enhanced Electrode 700-103027 or EQUAL/10/EA DUE: 11-03-2014 1:30PM Eastern - Attachment

Notice Date
10/29/2014
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
VA24915Q0058
 
Response Due
11/3/2014
 
Archive Date
12/3/2014
 
Point of Contact
David Milner
 
E-Mail Address
milner@va.gov<br
 
Small Business Set-Aside
Total Small Business
 
Description
This is a COMBINED SYNOPSIS/SOLICITATION for commercial items prepared in accordance with the format in Subpart 12.6, and is being conducted under FAR Subpart 13; simplified acquisition procedures apply. VA will conduct the procurement according to a combination of FAR Part 12, Acquisition of Commercial Items and Part 13, Simplified Acquisition Procedures as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a written solicitation will not be issued. The solicitation number is VA249-15-Q-0058 and is issued as a Request For Quotation (RFQ) The provisions and clauses incorporated into this solicitation document are those in effect through Federal Acquisition Circular 2005-69, August 1, 2013. Provisions and clauses incorporated by reference have the same force and effect as if they were given in full text. The full text of the Federal Acquisition Regulations (FAR) and Veterans Affairs Acquisition Regulations supplement (VAAR) can be accessed on the Internet at http://www.arnet.gov/far (FAR) and http://vaww.appc1.va.gov/oamm/vaar (VAAR) This solicitation is issued as a small business set-aside. The North American Industry Classification System (NAICS) code is 339112, and the size standard is 500 employees. This requirement consists of one (1) line item: CLIN 0001: StarBurst Xli-enhanced Electrode 700-103027 or EQUAL/10/EA Salient Characteristics: 1.Length: 12 cm 2.Scalable, spherical ablations (4-7 cm) 3.Dynamic, real-time temperature readouts 4.Needle track ablation 5.Expandable array configuration 6.Infusion-based system to increase conductivity of ablation zone 7.Ergonomic one hand design 8.Integrated tubing set 9.Nine arrays plus active trocar tip 10.Four thermocouples 11.Pre-attached disposable main cable 12.Must be compatible with RF Generator and IntelliFlow Pump Model 1500X NOTE: Offerors submitting quotations on Equal items shall provide the Manufacturer's Name, Brand and Part Number for each item quoted. To be technically acceptable the products quoted shall be Brand Name or Equal to StarBurst Xli-enhanced Electrode 700-103027. Delivery FOB Destination to Lupe Coronado, Memphis VA Medical Center, 1030 Jefferson Ave, Memphis, TN 38104 52.212-1 Instructions to Offerors - commercial Items, apply to this solicitation with the following addenda, 52.225-25, VAAR 852-215-70, 852.233-70; 852.233-71 52.212-2, Evaluation - Commercial Items: FAR provision 52.212-2 does not apply to this solicitation. Award will be based on lowest price technically acceptable offer. 52.212-4 Contract Terms and Conditions - Commercial Items: apply to this solicitation with the following addenda; FAR 52.210-75; 52.232-99dev; VAAR 852.203-70, 852.211-70; 852.232-72, 852.246-70, 852.252-70; 852.246-71 52.212-5 Contracts Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items; The following FAR clauses identified at paragraph b of FAR 52.203-6; 52,204-10; 52.209-6; 52.212.5 are considered checked and are applicable to this acquisition: 52.203-6, 52.219-28, 52.222-3, 52..222-19, 52.222-21; 52.222-26; 52.222-35, 52.222-36, 52.222-37, 52.225-1, 52.225-13; 52.232-34 52.211-6 Brand Name or Equal applies RESPONSES ARE DUE MONDAY, November 3, 2014 on or before 1:30 PM Eastern. Electronic offers will be accepted and are encouraged; submit quotation to - David Milner, NCO-09, david.milner@va.gov Include in the Subject Line RF Ablation Device/ company name. Point of contact for this solicitation is David Milner, 615-225-5631, david.milner@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/VA24915Q0058/listing.html)
 
Document(s)
Attachment
 
File Name: VA249-15-Q-0058 VA249-15-Q-0058.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1703798&FileName=VA249-15-Q-0058-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1703798&FileName=VA249-15-Q-0058-000.docx

 
File Name: VA249-15-Q-0058 S02-Combined Synopsis - 614-RF Ablation Electrode.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1703802&FileName=VA249-15-Q-0058-001.doc)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1703802&FileName=VA249-15-Q-0058-001.doc

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Memphis VA Medical Center;1030 Jefferson Ave;Memphis, TN
Zip Code: 38104
 
Record
SN03561160-W 20141031/141030001802-e0eb8fe1046242811d8572fda2b76256 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.