SOURCES SOUGHT
41 -- Lanham FB Chillers Replacement
- Notice Date
- 11/5/2014
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Acquisition Management (7PQB), 819 Taylor St. Room 12B01, Fort Worth, Texas, 76102, United States
- ZIP Code
- 76102
- Solicitation Number
- 000012
- Archive Date
- 12/5/2014
- Point of Contact
- Ky Nguyen-Zubroski,
- E-Mail Address
-
ky.nguyen@gsa.gov
(ky.nguyen@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- Project Description The General Services Administration, Public Building Service, Region 7, is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support the removal of one 750 Ton and one 500 Ton existing water cooled chiller located in the Fritz Lanham Federal Office Building at 819 Taylor Street. The units are physically located in the 15th floor penthouse and can be removed through the large existing pneumatic louvered assembly. This project also includes the removal of cooling tower #4 from the 14th floor roof. No new cooling tower will be installed. A crane will most likely be required to remove the existing units and for installation of the new units. Removal includes recovering refrigerant, disconnecting all electrical, controls and piping to the chillers/tower. The contractor will also be required to replace the old chillers with new units. The new unit types are as follows: one 750 ton and one 475 ton, nominal capacity, equal to or better than SMARDT Frictionless Centrifugal Chillers utilizing oil free, magnetic bearing, magnetic high-speed variable speed centrifugal compressor magnetic drive technology. All necessary connections, valves, pumps, piping and electrical modifications shall be included. In addition, the units shall be configured and connected to the current building automation system (BAS) which will be upgraded to JACE 7 in this project. A temporary street closure permit thru the city of Ft Worth may be required and costs are the responsibility of the contractor. Included in the scope of work shall be the modification of the existing refrigerant monitoring system. The Contractor will have 60 days to complete the work after the chiller arrives on site. The applicable North American Industry Classification System (NAICS) code to be assigned to this procurement is 238220; the associated small business size standard is 15 million. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals. Submission of any information in response to this market survey is purely voluntary. The government assumes no financial responsibility for any costs incurred associated to this request for capability information. If your organization has the potential capacity to perform these contract services, please provide the following information: (1)A complete and current record of your registration within the System for Award Management, located at https://www.sam.gov/. The record shall include your DUNS number, organization name, address, contact name, email address, web site address, telephone number, type of organization, and small business type(s). (2)A capability statement supporting claims of organizational and staff capability to perform the tasks listed in the "Project Description" paragraph above. (3)A list of three chiller removal and installation contracts (500 Ton or larger) and associated federal customers performed within the last 5 years. A point of contact (Building/Property Manager, Contracting Officer, etc.) to each identified contract related to item (3) above. Please provide the name, title, agency (or like concern), telephone number, email address, and physical address with the associated contract. Experience of both the prime contractor and subcontractors will be considered. GSA requests that potential sources only submit the minimum information necessary and no more than four (4) pages. The SAM.gov record does not count toward the 4 page minimum. The result of this market research will contribute to determining the method of procurement, including type of small business set-aside. NO LARGE businesses need to respond to this notice. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. However, GSA may contact sources to gather additional information as required. Submission Instructions: Interested parties, excluding large businesses, who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 4:00 PM (CDT), Thursday, November 20, 2014. All responses under this Sources Sought Notice must be emailed to Ky Nguyen-Zubroski, Contract Specialist, at the following address: ky.nguyen@gsa.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/7PMO/000012/listing.html)
- Place of Performance
- Address: Fritz G. Lanham Federal Office Building, 819 Taylor Street, Fort Worth, Texas, 76102, United States
- Zip Code: 76102
- Zip Code: 76102
- Record
- SN03566736-W 20141107/141105234312-f89e4d840fd2d045d6af2afcdf60cb75 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |