SPECIAL NOTICE
C -- Nose Dock 7 A&E - Announcement Attachments
- Notice Date
- 12/5/2014
- Notice Type
- Special Notice
- NAICS
- 541330
— Engineering Services
- Contracting Office
- Department of the Air Force, Pacific Air Forces, 354 CONS - Eielson, 2310 Central Ave, Eielson AFB, Alaska, 99702, United States
- ZIP Code
- 99702
- Solicitation Number
- barker-ftqw06-1467-nosedock7-ae
- Archive Date
- 1/24/2015
- Point of Contact
- William P. Barker, Phone: 9073772766
- E-Mail Address
-
william.barker.1@us.af.mil
(william.barker.1@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- Attachment 5 - Past Performance Questionnaire Attachment 4 - SF 330 Attachment 3 - Statement of Work Attachment 2 - Selection Criteria Attachment 1 Instructions to Offerors ARCHITECT-ENGINEERING (A-E) SERVICES AT EIELSON AFB, AK. “Notice to Offeror(s)/Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date for receipt of proposals. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs.” The 354th Contracting Squadron is seeking qualification packages and past performance information from vendors interested in providing professional architect and engineering services at Eielson AFB, AK to install Nose Dock 7 fire suppression system. BACKGROUND: Nose dock 7 (bldg. 1232) houses maintenance functions for F-16 aircraft at Eielson AFB, Alaska. It was constructed in 1965. There have been several renovations and remodel projects since the original construction. After installation of insulated roof panels roof deflection due to snow loads has been an issue with this building. Asbestos has been abated with previous projects, but some is still present throughout the building. Presence of lead based paint should be expected. There is currently no fire suppression in the building. This is a competitive selection process in which competing offeror’s qualifications will be evaluated in accordance with (IAW) FAR Part 36.6 to determine the most highly qualified firms. The Government intends to award one Firm Fixed-Price contract. IAW FAR 36.603(b): To be considered for architect-engineer contracts, a firm must file with the appropriate office or board the Standard Form 330, “Architect-Engineer Qualifications,” Part II and when applicable, SF 330, Part I. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this posting; all costs associated with responding will be solely at the interested parties’ expense. Failure to respond to this post does not preclude participation in the subsequent technical evaluation so long as a firm’s SF 330 is currently on file with the 354th Contracting Squadron. It is the responsibility of the potential offerors to monitor these sites for additional information pertaining to this requirement. This acquisition is being solicited on an unrestricted basis. The NAICS 541330 (Engineering Services) applies to this acquisition, with a small business size standard of $15M. The work to be performed shall include but is not limited to: 1. Attending a pre-investigation meeting 2. Investigating site conditions, options, etc. – investigation shall include, but not be limited to whether or not a separate water storage and pumping facility will be required to provide adequate system flows 3. Collecting and reviewing project data and records 4. Developing design concepts and cost estimates 5. Submitting an investigation report 6. Attending review meetings 7. Making the revisions requested by the Government 8. Submitting intermediate design documents 9. Producing a complete design (35%, 65%, 95%, and 100% submissions) A-E EXPERIENCE REQUIREMENTS: A-E’s experience shall include that which is commensurate with the requirements specific to the scope of design. A. The A-E shall demonstrate experience with design of High Expansion Foam fire suppression systems in hangars as well as wet and dry-pipe fire suppression systems and associated alarms. B. The A-E shall demonstrate that they have experienced personnel with Alaska Registrations, adequate capacity and depth in the following disciplines: 1. Fire Protection Engineering 2. Mechanical Engineering 3. Structural Engineering 4. Architecture 5. Civil Engineering 6. Electrical Engineering C. The A-E shall demonstrate that they have experienced personnel with certification and adequate capacity and depth in the following disciplines: 1. Environmental Engineer 2. Industrial Hygienist 3. Land Surveyor The Air Force requires complete and functional designs that are appropriate for the sub-arctic environment for interior Alaska and that meet all applicable Federal, State, Local, Industry, U.S. Air Force and Eielson AFB requirements. The A-E shall be responsible for all travel and lodging arrangements and expenses involved in the performance of work under this contract. The A-E shall furnish the Air Force with complete and usable products to include: planning documents, investigative reports, study reports, design analyses, project drawings, technical provisions (specifications), equipment layouts, cost estimates, submittal registers, quality assurance plans, constructability review reports, construction bidding amendments, construction contract modifications, and other documents. Attachments: Drawings and charts attached to this synopsis are for planning purposes only; intended to assist firms in establishing their qualification packages. The Government assumes no responsibility for any conclusions or interpretations made by the Contractor based on the information made available by the Government. Nor does the Government assume responsibility for any understanding reached or representation made concerning conditions which can affect the work by any of its officers or agents before the execution of this contract, unless that understanding or representation is expressly stated in this contract. QUESTIONS: All questions regarding this synopsis must be submitted in writing no later than 3 January 2015. Primary POC email: william.barker.1@us.af.mil Alternate POC email: donovan.wall@us.af.mil The following documents are considered attachments to this A&E Announcement: Attachment 1 - Instructions to Offerors Attachment 2 - Selection Criteria Attachment 3 - Statement of Work Attachment 4 – SF 330 Attachment 5 – Past Performance Questionnaire
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/PAF/354CONS/barker-ftqw06-1467-nosedock7-ae/listing.html)
- Place of Performance
- Address: Eielson AFB, Eielson AFB, Alaska, 99702, United States
- Zip Code: 99702
- Zip Code: 99702
- Record
- SN03588787-W 20141207/141205234515-3a3dac95dc6d77da3bdc9bc0bb1e3e7f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |