Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 24, 2015 FBO #4809
SOLICITATION NOTICE

59 -- ELECTRICAL ITEMS

Notice Date
1/22/2015
 
Notice Type
Combined Synopsis/Solicitation
 
Contracting Office
Hwy 155, W/H B, Door 6, Industrial Area, Grand Coulee, WA 99133
 
ZIP Code
99133
 
Solicitation Number
0040190524
 
Response Due
1/30/2015
 
Archive Date
7/29/2015
 
Point of Contact
Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
 
E-Mail Address
Clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.The solicitation number is 0040190524 and is issued as an invitation for bids (IFB), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-79. The associated North American Industrial Classification System (NAICS) code for this procurement is 335999 with a small business size standard of 500.00 employees.This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2015-01-30 17:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Grand Coulee, WA 99133 The Bureau of Reclamation requires the following items, Brand Name or Equal, to the following: LI 001: STARTER, MAGNETIC, TYPE U, SIZE 1, 3-POLE, 110 VOLT. FEDERAL #5U131-01, CUTLER HAMMER #AN16DNOAB, FURNAS #14DA32AA, OR EQUAL., 3, EA; LI 002: WIRE, COPPER, THHN, 12 AWG, 1C, RED, 19 STRAND, 600 VDC, NO SHIELD, PVC INSULATION. FURNISH IN 500 FOOT SPOOL., 7500, FT; LI 003: CAPACITOR, 50 MFD, 1500 VDC, (AT PLUS 40 DEGREE CENTIGRADE), MAXIMUM OPERATING TEMPERATURE 85 DEGREE CENTIGRADE, PLASTIC CAPACITORS INC, NUMBER LX15-506Y, OR EQUAL., 4, EA; LI 004: FUSE CARTRIDGE, 600 VOLT, 60 AMP, 5.5 INCH LONG, 1.06 INCH DIAMETER, CLASS RK5, CURRENT LIMITING, DUAL ELEMENT, TIME DELAY. FURNISH 10 PER PACK. BUSSMAN FRS-R-60 FUSETRON., 50, EA; LI 005: RECEPTACLE, ELECTRICAL, 20 AMP, 125 VOLT, 2 POLE, GROUND FAULT INTERRUPTER, WITH FEED-THRU CAPABILITIES, WITH NEMA 5-20R CONFIGURATION DUPLEX RECEPTACLE. FURNISH 10 PER PACK. P AND S 2091 SI, HUBBLE GFR5352IA, P&S 2094-I, 2095-SI, LEVITON 7899-I, OR EQUAL., 160, EA; LI 006: SOCKET RELAY, 1-3/4 X 3-1/2 INCH, (11 PIN), SIZE NOT TO EXCEED ABOVE, WITH SCREW TYPE TERMINALS WHICH WILL ACCEPT RING-TONGUE CONNECTORS, 15 AMP, 250 VOLT, 3PDT, 11 PIN SOCKET. PREFER GRAY COLOR FOR UNIFORMITY.POTTER BRUMFIELD 27E121, OR EQUAL., 50, EA; LI 007: CONNECTOR CORD, MALE, 4 POLE, 4 WIRE, 60 AMP, 600 VOLT, 250 VDC, WATERTIGHT PLUG, TYPE FC, WITH HINGED FLAP. MUST BE COMPATIBLE WITH RUSSELL & STOLL 7227 W-78. RUSSELL & STOLL 7227 W-78 OR EQUAL., 3, EA; LI 008: SOLENOID, PRESSURE REDUCING VALVE, 120 VOLT, ENERGIZE TO CLOSE, NORMALLY OPEN, FOR WATTS ACV MODEL 115-4 PRESSURE REGULATING VALVE, 110-120 VOLT, 60 HZ, 10.1 WATTS, PRV VALVE, MAX OPERATING PRESSURE AIR AND WATER = 150 PSI, MAX OPERATING PRESSURE LIGHT OIL = 125 PSI, BRASS BODY, COIL CLASS FT. ASCO REDHAT PART NO. 8210G34, ORDER CODE 20154, OR EQUAL., 3, EA; LI 009: TRANSFORMER, POTENTIAL, 14400 VOLT, 110 KV, 120:1 RATIO, WESTINGHOUSE STYLE NO. 7525A67G10, TYPE V1Z-11, OR EQUAL., 2, EA; LI 010: CONNECTOR BOX CONDUIT, FLEXIBLE, 1/2 INCH LIQUID TIGHT, GALVANIZED, STRAIGHT, INSULATED THROAT, DOUBLE BEVEL SEALING RING, TRADE SIZE. FURNISH 25 PER PACK. THOMAS AND BETTS 5332, O-Z GEDNEY 4Q-50T, OR EQUAL., 50, EA; LI 011: COVER, OUTLET BOX RECEPTACLE, SINGLE GANGE, DUPLEX OUTLET, WALL RAISED, CADMIUM PLATED STEEL, NATURAL FINISH, FOR UTILITY/HANDY BOX. FURNISH 25 PER PACK. APPLETON #58C7, RACO 864, OR EQUAL., 50, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, Bureau of Reclamation intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. Bureau of Reclamation is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 30 calendar days after close of Buy. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. See attached clauses. IF SUBMITTING A QUOTE FOR AN EQUAL, YOU MUST PROVIDE MANUFACTURER'S TECHNICAL LITERATURE FOR REVIEW IN ORDER TO BE CONSIDERED FOR AWARD.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/f3023c6129097fe17a80728fa98358b5)
 
Place of Performance
Address: Grand Coulee, WA 99133
Zip Code: 99133
 
Record
SN03622172-W 20150124/150122234719-f3023c6129097fe17a80728fa98358b5 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.