SOLICITATION NOTICE
66 -- Biopotential
- Notice Date
- 1/27/2015
- Notice Type
- Presolicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- RTPPODUS Environmental Protection Agency109 T.W. Alexander DriveMail Code: AA005Research Triangle ParkNC27709USA
- ZIP Code
- 00000
- Solicitation Number
- RFQ-RT-15-00032
- Response Due
- 2/1/2015
- Archive Date
- 3/3/2015
- Point of Contact
- Louis C. Williams Jr
- E-Mail Address
-
RFQ-RT-15-00032
(williams.louis@epa.gov)
- Small Business Set-Aside
- N/A
- Description
- The intent of this synopsis is to state the Government's intention to sole source this acquisition to Data Sciences International. Therefore, no solicitation (RFQ) is available. The U.S. EPA?s Office of Research and Development, Immediate Office of the Assistant Administrator (IOAA) is in need of an exchange of 22 ETA-F10 mouse transmitters and an upgrade of 10 C50-PXT, rat blood pressure transmitters to 10 HD-S11 models. The EPA laboratory monitors electrocardiogram, heart rate, blood pressure, body temperature, and activity by using transmitters (aka telemeters) to assess the effects of air pollutants and elucidate mechanism of action. The Data Sciences International, Inc. (DSI) PhysioTel? Implantable Telemetry is designed for monitoring and collecting data. The implantable transmitter senses, processes and transmits information via telemetry from within an animal. The transmitter is only one component of the complete DSI System which includes software, acquisitio n hardware, and calibration hardware. With these devices, researchers and scientists can measure arterial pressure, ECG, temperature, activity, and temperature among other parameters. The ETA-F10 transmitters are used to measure biopotential (ECG), temperature and activity data in mice. The ETA-F10 is the smallest of the single channel biopotential transmitter series. The ETA-F10 is most commonly used for cardiovascular research, where ECG and heart rate data are desired. Designed for small animals, the HD-S11 has one catheter for measuring pressure and one biopotential lead for measuring ECG signals. Temperature and activity are also simultaneously recorded. This implant has several advancements over its predecessor - the C50-PXT ? including improved physiologic measurement sensitivity, auto-loading of calibration data reduces configuration time and eliminates data entry error, animal ID ensures data collection is from the intended animal, and battery ON-time counter help s track study duration and remaining battery life. The justification for sole source procurement of the above components is based on the following factors: 1) ? the measurement of blood pressure by intra-arterial catheterization is considered by the EPA to be the only reliable method of measuring blood pressure in laboratory rodents; 2) - these telemeters and all accompanying required equipment are manufactured by Data Sciences International; 3) - after being used, these telemeters require refurbishment. DSI is the only company that produces this proprietary telemeter model. No other transmitter will work with our DSI hardware and software systems. Thus, DSI is the only company that can exchange these used telemeters (ETA-F10s for mice and C50-PXTs for rats) for new telemeters; 4) - note that DSI no longer manufactures (and refurbishes) C50-PXTs and has replaced them with a newer model (i.e. HD-S11s). Thus, EPA must exchange its expired C50-PXT models for the replacemen t HD-S11 models. DSI transmitters are proprietary and DSI does not have re-sellers or distributors. DSI is the sole provider of DSI transmitters in the U.S. The circumstance permitting Other than Full and Open Competition is FAR 6.302-1 Sole Source, Only one responsible source and no other supplies or service will satisfy agency requirements. All interested parties who believe they can provide the required product or a similar product that meets the above described requirements should fully explain their product capabilities and qualifications in writing within 5 days from the date of this announcement. Consequently, any response(s) failing to provide the aforementioned data but instead choosing merely to submit a routine letter requesting a copy of the RFQ will not be honored. Offerors must submit all technical questions / responses concerning this synopsis electronically through FedConnect. Notices of any modifications to this FBO procurement announcement, including Requests for Proposals and amendments, will be posted using the FedConnect web portal. FedConnect can be accessed at https://www.fedconnect.net/Fedconnect/. Questions regarding the content of the subject announcement must be submitted through the FedConnect portal. You must register with FedConnect as an interested party to submit questions and to view responses. FedConnect is a web portal that connects agencies and vendors to streamline the process of doing business with the federal government. Through FedConnect contractors will be able to receive, review and respond to contract pre- and post-award actions and documents such as correspondence, request for proposals, tasking instruments and contract modifications. The use of FedConnect also furthers the EPA?s commitment to moving towards a paperless acquisition environment by reducing its carbon footprint and conducting its business in an ecologically friendly manner. There is no charge to use FedConnect. Vendors can register with FedConnect at www.fedconnect.net/FedConnect/. For assistance in registering or for other FedConnect technical questions please call the FedConnect Help Desk at (800) 899-6665 or email at support@fedconnect.net. In addition, all vendors must be registered in the System for Award Management (SAM), as this facilitates registration for FedConnect. Please note that vendors MUST have their SAM profile set to ?public,? otherwise FedConnect will not be able to access the SAM information required to validate vendor credentials. Registration may be completed and information regarding the registration process may be obtained at http://www.sam.gov. There is no charge for registration in SAM.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/EPA/OAM/CMD/RFQ-RT-15-00032/listing.html)