Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 05, 2015 FBO #4821
DOCUMENT

41 -- 515-15-1-390-0167 - Heating Unit - Attachment

Notice Date
2/3/2015
 
Notice Type
Attachment
 
NAICS
332410 — Power Boiler and Heat Exchanger Manufacturing
 
Contracting Office
Department of Veterans Affairs;Ann Arbor Healthcare System;Network 11 Contract Office;2215 Fuller Road;Ann Arbor MI 48105
 
ZIP Code
48105
 
Solicitation Number
VA25115Q0121
 
Response Due
2/9/2015
 
Archive Date
3/11/2015
 
Point of Contact
Wendy Stewart
 
E-Mail Address
5-5605<br
 
Small Business Set-Aside
N/A
 
Description
Amendment A00002 Update Salient Characteristics This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation, VA251-15-Q-0121, is issued as a request for quotes (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-12. The North American Industry Classification System (NAICS) number is 332410 and the business size standard is 500 employees. Requestors shall state their business size on their proposal. Evaluations will be based on lowest price, technically acceptable. They must include the exact specifications of the salient characteristics listed below. All responsible sources may submit a proposal which shall be considered by the contracting officer. Based on a "Venmar VHC-36" or a "Trane, Horizon - Outdoor Air Unit (B/G) B0036" The following salient details must be included in a proposal for this unit: 1.100% outside air-100% exhaust, Make up air unit 2.Unit required to ventilate a 300 SF space at 30 Air Changes Per hour (800 CFM estimated minimum) 3.Maintain room heating and cooling set point of 68 F/20C with a relative humidity of range of 30% low to 60% high side 4.208V/60Hz/ 3 Phase Electric for unit power 5.Laminar airflow 6.Cooling by Direct Expansion (DX) with appropriate controls to run in low ambient conditions, I.E. crank case heaters, head pressure controls, ETC.. 7.Heating will be done with steam coil. (Not electric) 8.Humidification, plant steam is acceptable. 9.Dehumidification will be accomplished thru the DX coils of the unit. 10.Controls will be connected and compatible to Automated Logic and use the BACNET protocol. 11.Energy recovery should be done thru a plate and frame and not a standard fabric wheel (no cross contamination). 12.Filtration is required to meet clean room standards (Design and RV). Requiring 1st pre filter is a MERV 7 the 2nd pre filter is MERV 13 with final filtration being MERV 17 for a complete HEPA filter system. 13.Unit will be pad mounted on curb with side discharge Quantity needed: 1 Installation and removal of material not needed.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAAAHCS506/VAAAHCS506/VA25115Q0121/listing.html)
 
Document(s)
Attachment
 
File Name: VA251-15-Q-0121 A00002 VA251-15-Q-0121 A00002.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1844169&FileName=VA251-15-Q-0121-A00002000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1844169&FileName=VA251-15-Q-0121-A00002000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN03631991-W 20150205/150203235142-789d378084f36e78d2ecfd66cf887f09 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.