SOLICITATION NOTICE
66 -- High Voltage Indicator with Probe
- Notice Date
- 2/13/2015
- Notice Type
- Presolicitation
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, PK/PZ Tinker AFB, 3001 Staff Drive, Ste 1AG76A, Tinker AFB, Oklahoma, 73145-3015, United States
- ZIP Code
- 73145-3015
- Solicitation Number
- FA8126-15-Q-0100
- Point of Contact
- Michael H Moucka, Phone: 405/739/3930
- E-Mail Address
-
michael.moucka@tinker.af.mil
(michael.moucka@tinker.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- 1. Item Description 1.1. The Indicator with High Voltage Probe is used to measure direct current and alternating high voltage current to a high degree of accuracy. The indicator must be capable of measuring voltage and displaying the measured voltage without the use of an external probe, as well as measuring and displaying voltage with the use of an external probe. As a minimum, the unit must meet the following specifications: Direct Input Measurement (Indicator without the use of an external probe) Maximum Input Voltage: 10KV DC, 10KV AC RMS, 15KV peak Input Impedance: 110MΩ ±2% in parallel with <5pF to chassis ground (High or Direct terminal) DC Voltage Accuracy: <0.03% of reading + 0.03V + ½ digit Common Mode Error: <0.05% of the COMMON terminal DC voltage AC Voltage Accuracy (True RMS, Band Selectable): 0.01 to 1Hz : <0.12% of reading + 0.1V + ½ digit 10 to 65Hz : <0.12% of reading + 0.1V + ½ digit 30 to 200Hz : <0.12% of reading + 0.1V + ½ digit 200 to 450Hz : <0.4% of reading + 0.1V + ½ digit 450 to 600Hz : <0.75% of reading + 0.1V + ½ digit DC Rejection >65 dB, with up to >100dB in certain modes Common Mode Error <0.05% + (0.008% times frequency in Hz) of the COMMON terminal AC voltage Measurement Resolution: DC & AC: 0.01V (<1400Vpk±10%), 0.1V (<14KVpk±10%), 1V (otherwise). Capable of displaying up to 6 digits of resolution. External Input Measurement (Indicator with the use of an external probe) Maximum Input Voltages: 35KVDC, 30KV AC RMS, 42.5KV peak Input Impedance: 200MΩ ±2% in parallel with <5pF to chassis ground DC Voltage Accuracy: (up to 35 KVDC); 0.025% of reading + 0.07V + ½ digit Common Mode Error: <0.05% of the COMMON terminal DC voltage AC Voltage Accuracy (True RMS, Band Selectable): (up to 35 KVAC); 0.01 to 1Hz : <0.15% of reading + 0.2V + ½ digit (up to 35 KVAC); 30 to 200Hz : <0.08% of reading + 0.2V + ½ digit* (up to 35 KVAC); 200 to 450Hz : <0.6% of reading + 0.2V + ½ digit (up to 35 KVAC); 450 to 600Hz : <1.25% of reading + 0.2V + ½ digit *If frequency is within ± 10Hz of calibration frequency, measurement accuracy is improved to (up to 35 KVAC); 30 to 200Hz : <0.05% of reading + 0.2V + ½ digit. Measurement Resolution: DC & AC: 0.01V (<800Vpk±10%), 0.1V (<8KVpk±10%), 1V (otherwise). Capable of displaying up to 6 digits of resolution. Environmental/Physical specifications: Operating Environment 0 to 50C, <85% RH (non-condensing). Must operate up to 35C without degradation of voltage capability. Dimensions: Indicator not to exceed 9" x 6" x 11". Probe not to exceed 25" x 9.5" x 6" Power: AC Source 45 to 450Hz, 100 to 265Vrms at <15W (25VA maximum) DC Source 11 to 16Vdc at <1.2A Standard Accessories shall include: A. Operator's Manual (hard copy or digital copy) B. NIST traceable certificate of calibration with data C. Direct input test leads D. Chassis ground lead E. Power supply or power cord to power all devices (as applicable).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/OCALCCC/FA8126-15-Q-0100/listing.html)
- Place of Performance
- Address: Tinker AFB, Okalhoma City, Oklahoma, 73145, United States
- Zip Code: 73145
- Zip Code: 73145
- Record
- SN03642831-W 20150215/150213235149-46036a2b7be8c124ba6a9d3114a83090 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |