Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 19, 2015 FBO #4835
MODIFICATION

Z -- Lower Monumental Dam Unit 1 Rewind, Linkage, and Cavitation Repair, and Unit 2 Cavitation Repair

Notice Date
2/17/2015
 
Notice Type
Modification
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
Attn: CENWW-CT 201 North 3rd Avenue Walla Walla WA 99362-1876
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF-15-R-0001
 
Response Due
5/4/2015
 
Archive Date
7/31/2015
 
Point of Contact
Phyllis Buerstatte, Contract Specialist, Phone 509-527-7211, Fax 509-527-7802, - Jani C Long, Contract Specialist, Phone 509-527-7209, Fax 509-527-7802
 
E-Mail Address
Phyllis.L.Buerstatte@usace.army.mil, jani.c.long@usace.army.mil
 
Small Business Set-Aside
N/A
 
Description
Notice amended 17 February 2015. This notice amendment changes the anticipated solicitation release date, the site visit date, and the due date for receipt of proposals. Solicitation will be released to offerors on or about 10 March 2015. Site visit is scheduled for 23 March 2015. Proposals will be due on or about 04 May 2015. Foreign nationals wishing to attend the site visit should apply immediately, as it takes 2-4 weeks to obtain clearance. (See below.) Construction Project: LOWER MONUMENTAL UNIT 1 REWIND, LINKAGE, AND CAVITATION REPAIR AND UNIT 2 CAVITATION REPAIR This will be a firm fixed-price construction contract located at Lower Monumental Lock and Dam in Franklin County, Washington. Estimated construction magnitude is between $10,000,000 and $25,000,000. Performance and payment bonds (100%) will be required. Time for completion is expected to be 575 calendar days following the Contractor's receipt of Notice to Proceed (NTP) See solicitation for details. The solicitation is open to both large and small business concerns. The small business size standard for NAICS 237990 is no more than $36,500,000 in average annual receipts. DESCRIPTION OF WORK: The work described herein requires mobilization, pre-disassembly operational tests and measurements, hydraulic turbine generator unit disassembly, turbine runner disassembly, BLH internal component replacement and repair, generator rewind, unit runner and discharge ring cavitation repair, turbine runner reassembly, hydraulic turbine generator unit reassembly, reassembly operational tests and measurements, demobilization, and other optional provisions. The work of the linkage upgrade of Unit 1 at Lower Monumental is the complete disassembly of the turbine runner, the installation of Government-furnished BLH internal hub components, and reassembly of the turbine runner for Unit 1. The installation of Government-furnished BLH internal hub components will require final machining and clean up of existing turbine runner parts and new parts to operate as designed. The original manufacturer of the turbine is Baldwin-Lima-Hamilton (BLH) Corporation. The Kaplan turbine repair work includes furnishing and installing all required scaffolding and all required tools, lifting, and handling devices not otherwise furnished by the Government. Provide on-the-job qualified supervisor(s) completely familiar with the type of equipment involved to direct the disassembly, repair, and reassembly of the turbine runner as specified. Perform all work on the unit using skilled craftsmen who are familiar with the type of work and the equipment involved. This project involves cavitation repair on the turbines and discharge ring of Units 1 and 2 of Lower Monumental Lock and Dam. Requirements of this project shall include machine and weld repair, weld inspection and epoxy injection on the discharge ring and turbine. Unit 2 cavitation repair shall occur first, and be performed with the runner in place. Unit 1 shall be completed after Unit 2 is back in service, and can be performed with the unit disassembled. Generator repairs on Unit 1 include replacement of the stator core and winding and accessories, and supplying spare parts for Lower Monumental Generator Unit 1. Unit 1 rotor repairs include cleaning, inspecting and testing the rotor. At the option of the Government, work would include reinsulating rotor field leads and refurbishing all rotor poles. The turbines are Kaplan type manufactured by Baldwin-Lima-Hamilton (BLH) and the generators are manufactured by General Electric (GE). Request for Proposals No. W912EF-15-R-0001 will be posted to the FedBizOpps (FBO) website approximately 10 March 2015. A site visit is expected to be offered on or about 23 March 2015. Proposals are expected to be due on or about 04 May 2015. See solicitation for details about the site visit and the proposal due date. When issued, the solicitation documents for this project will be available at https://www.fbo.gov Important Note Regarding Access for Foreign Nationals. It takes from 2-4 weeks to obtain clearance for foreign nationals to enter the project site. If your company wishes to have a foreign national participate in the site visit for this project, you are strongly encouraged to submit the required identification immediately. To request clearance for foreign nationals, submit the names of all foreign nationals proposed for site visit attendance, along with documentation to verify that he/she was legally admitted into the United States and has authority to work and/or go to school in the US. Such documentation may include a US passport, Certificate of US citizenship (INS Form N-560 or N-561), Certificate of Naturalization (INS Form N-550 or N-570), foreign passport with I-551 stamp or attached INS Form I-94 indicating employment authorization, Alien Registration Receipt Card with photograph 9INS Form I-151 or I-551), Temporary Resident Card (INS Form I-688), Employment Authorization Card (INS Form I-688A), Reentry Permit (INS Form I-327), Refugee Travel Document (INS Form I-571), Employment Authorization Document issued by the INS which contains a photograph (INS Form I-688B). Send this information by email to Phyllis.L.Buerstatte@usace.army.mil. Foreign nationals must have received clearance prior to being granted access to the project site. Important Note: The FBO Response Date listed elsewhere in this synopsis is for FBO archive purposes only. It may have no relationship to the actual proposal due date. The proposal due date and time will be contained in the solicitation and any solicitation amendments that are issued. No CDs or hard copies will be made available by the Government. Downloads are available only through the FBO website. Bidders are responsible for checking the FBO website frequently for any update(s) to the notice. The Government is not responsible for any loss of internet connectivity or for a bidder's inability to access the document posted on the referenced website. To obtain automatic notifications of updates to this solicitation, you must log in to www.fbo.gov and add the solicitation to your Watchlist. If you would like to list your firm so others can see you are an interested vendor, you must click the Add Me To Interested Vendors button in the listing for this solicitation. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (17-FEB-2015); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-15-R-0001/listing.html)
 
Place of Performance
Address: Lower Monumental Dam, 5520 Devils Canyon Road Kahlotus, WA
Zip Code: 99335
Country: US
 
Record
SN03644119-F 20150219/150217233045 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.