SOLICITATION NOTICE
Z -- Replace three damaged boilers - FAR Clause and Wage Rates
- Notice Date
- 3/4/2015
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), BASE CLEVELAND, 1240 E 9TH ST FL 21, CLEVELAND, Ohio, 44199-2060, United States
- ZIP Code
- 44199-2060
- Solicitation Number
- 21-15-305PCV160
- Archive Date
- 3/31/2015
- Point of Contact
- Joseph D. Easton, Phone: 2169026339
- E-Mail Address
-
Joseph.D.Easton@uscg.mil
(Joseph.D.Easton@uscg.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- FAR Clause and Wage Rates MANITOWOC HOUSING 404, 406 AND 408 N. LAKE STREET, MANITOWOC, WI BOILER REPLACEMENTS PR# 2115305PCV160 PART 1 PROJECT DESCRIPTION 1.1 The Coast Guard requires a contractor fully qualified within the field of plumbing and HVAC system Installation and removal, to provide all labor, materials and equipment necessary to remove, dispose of and replace three boilers that have failed at CG owned housing located in Manitowoc, WI. PART 2 SCHEDULING 2.1 All work will be conducted between the hours of 7:30 a.m. through 4:00 p.m., Monday through Friday. PART 3 PREPARATION 3.1 Contractor will be responsible for any permits that may be required by Wisconsin state law and the City of Manitowoc, WI. PART 4 MATERIALS 4.1 Government furnished materials: The Coast Guard will not provide any materials. The contractor shall supply all materials. 4.2 Contractor Supplied Materials: The contractor shall provide all materials necessary for completion of the job. PART 5 APPLICATION 5.1 All work performed will be in compliance with all Federal, State and City plumbing and HVAC codes. PART 6 CLEAN UP 6.1 Contractor shall ensure area is left in a clean and orderly condition. 6.2 Upon completion of this project the Coast Guard representative will inspect all work before any payment is received. PART 7 CONTRACTOR PERFORMANCE SPECIFICATIONS 7.1 All work shall be accomplished in a professional manner and in strict adherence to current manufacturer standards and recommendations. 7.2 Contractor shall adhere to current codes, ordinances and OSHA safety regulations at all times. 7.3 Contractor will replace the three damaged boilers meeting the following specs: a. 83 or 84 percent efficiency b. Taco pump systems, automatic chimney lock, electronic ignition c. new vent piping for all three boilers d. 70,000 BTU natural gas boiler or equivalent. e. The BASE CLEVELAND OHMC DCC John Treme will provide the approval if any questions arise on type/make of new boiler to be installed. f. Contractor shall heat the space as required to ensure work can be completed since the water is shut off to the homes currently. PART 8 QUALITY ASSURANCE 8.1 Any work that does not meet the approval of the U.S. Coast Guard representative shall be immediately corrected. Unsatisfactory work shall be redone at the contractor's expense. Once all work is completed the Coast Guard representative will sign off on the project as completed. The local POC is MK1 Daniel Rodriquez (920) 793-1305 PART 9 LIABLITY INSURANCE 9.1 It is the responsibility of the contractor to provide their own liability insurance for contractor and employees. In no case will the Coast Guard assume liability for bodily injury to the contractor and/or employees.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/c14c832c4b24ee7eb783b9d7f352a9e8)
- Place of Performance
- Address: USCG Manitowoc Housing, 404,406, and 408 N. Lake Street, Manitowoc, Wisconsin, United States
- Record
- SN03659032-W 20150306/150304235514-c14c832c4b24ee7eb783b9d7f352a9e8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |