Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 11, 2015 FBO #4855
SOURCES SOUGHT

W -- Chemistery Analyzer (Vitros 4600 Brand Name) - Sources Sought Notice

Notice Date
3/9/2015
 
Notice Type
Sources Sought
 
NAICS
532490 — Other Commercial and Industrial Machinery and Equipment Rental and Leasing
 
Contracting Office
Department of the Air Force, Air Mobility Command, 92 CONS, BLDG 2451, 110 W ENT ST, STE 200, FAIRCHILD AFB, Washington, 99011-8568, United States
 
ZIP Code
99011-8568
 
Solicitation Number
FA4620-15-R-A005
 
Point of Contact
Susan D. Dalton, Phone: 5092472235, Audra Dorn, Phone: 509-247-2163
 
E-Mail Address
susan.dalton@us.af.mil, audra.dorn.3@us.af.mil
(susan.dalton@us.af.mil, audra.dorn.3@us.af.mil)
 
Small Business Set-Aside
N/A
 
Description
SOW Vitros Chemistry Analyzer 9MAR15 Sources Sought Notice - Chemistry Analyzer 9MAR15 Synopsis: FA4620-15-R-0005 - Vitros 4600 Chemistry Analyzer (Brand Name) THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. The 92d Contracting Squadron is seeking information on potential vendors qualified to provide proposals in response to a future solicitation. The proposed award will be for the lease of a Vitros 4600, fully Integrated Chemistry Analyzer (Brand Name) over a period of 1 base year + 4 option years, with a fixed cost-per-test (CPT) price. In accordance with the attached draft Statement of Work, the offeror must be capable of providing ALL of the following: 1) Equipment Lease, 2) Ongoing Reagent Supply, 3) 24/7 Technical Support, 4) Equipment Maintenance and Repair, and 5) Warranty and Replacement. Please submit your Notification of Interest if you are able to meet the requirements identified herein, or if you manufacture/lease an essentially similar item. The Chemistry Analyzer must be able to: 1) Perform General Chemistry, Drug (DAT/TDM), Immuno-rate, Specialty Plasma Protein, Electrolytes and other critical assays using the government's existing supply and materials (Ortho Clinical Diagnostics Vitros MicroSlides®), which will process serum, plasma, whole blood, urine and other body fluids simultaneously, with a throughput up to 160 primary tubes/samples or 845 tests per hour, and an onboard test capacity up to 8940 tests and 125 reagent/diluent positions, for one analyzer. 2) System must have self-contained onboard waste management and must not require external water/plumbing, drains, stirring mechanisms, mixing assemblies floor vents that have additional maintenance and cost and carry the potential for contamination risk that impact test results. 3) The system must not use reusable probes to aspirate the sample and reagent that may have the potential for carryover. Rather, prevents sample and/or reagent carryover by utilizing disposable tips therefore minimizing operation interruption. 4) Capable of performing automatic calibration/lot switching with on-board linearity program and the use of ready-to-use calibration materials without or little need of operator intervention; must have stable 6 month or longer calibrations and only requires calibration every 6 months or during change of reagent lot use; when critical system parts are changed due to service or maintenance, if Quality Control results are consistently outside acceptable ranges, or when government regulations require. 5) Provides rapid insertion of STAT tests without halting or manually adjusting routine patient runs (continuous load and unload); 6) Has an on-board reagent management system that provides stability tracking and predict user needs. Must be able to house all current assays packs plus at least one spare. Must be able to load packs while instrument is running. Stores reagents/supplies refrigerated on board up to 35 days or more; and performs automatic on-board monitoring & periodic maintenance at lab specified intervals; 7) The system must have a windows-based printer, read/write disk drive for data input and archiving up to 25,000 results using CD-ROM or USB flash drive; 8) System must be capable of interfacing with current laboratory management software: Composite Health Care System (CHCS); 9) Capable to integrate with a pre & post analytic automation system providing workload balancing; 10) The system should be able to handle > 95 % of testing volume from a single sample, with the ability detect short, clot, bubble, low, high viscosity samples. The instruments must be able to simultaneously perform the complete profile and meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA'88) and the Clinical and Laboratory Standards Institute (CLSI - formerly NCCLS). Due to current space limitations, the printer, UPS and analyzer should be no more than 215.3 cm wide x 141.2 cm high x 111.5 deep, with cover open no more than 204 cm high. 11) Fairchild Air Force Base requires a system to include the Engineering, Furnishing, Installation, and Testing (EFI&T) of equipment, security implementation, training, and life cycle support of the fielded system. Contractors must assess equipment, work flow, volumes and space to meet the individual site requirements with minimum cost. Contractor must propose the suggested/recommended equipment/reagents that will meet the requirements of the facility. The NAICS code for this procurement is 532490. Any information submitted is voluntary. Request interested firms submit (1) the NAME, ADDRESS, and PHONE NUMBER of the firm (including CAGE code); (2) a summary of their product, (3) their SIZE STATUS. Responses to this notice will assist the Government in identifying potential sources and determining if a set-aside of the solicitation is appropriate. Responses are requested no later than 2:00 p.m., PDT, on 20 March 2015 to be considered. It is anticipated that a solicitation will be issued in mid/late April 2015.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AMC/92CONS/FA4620-15-R-A005/listing.html)
 
Place of Performance
Address: 110 West Ent Street, Fairchild AFB, Washington, 99011, United States
Zip Code: 99011
 
Record
SN03661569-W 20150311/150309235014-cdd588d131f28f2704425029a6b1f96e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.