Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 13, 2015 FBO #4857
SOLICITATION NOTICE

61 -- Generator Step-up Transformer

Notice Date
3/11/2015
 
Notice Type
Presolicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
USACE District, Portland, Contracting Division (CECT-NWP), P.O. Box 2946, Portland, OR 97208-2946
 
ZIP Code
97208-2946
 
Solicitation Number
W9127N-15-R-0060
 
Response Due
8/6/2015
 
Archive Date
9/5/2015
 
Point of Contact
Gary Weir, 503-808-4624
 
E-Mail Address
USACE District, Portland
(gary.weir@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
NAICS Code: 335311 Contracting office address US Army Corps of Engineers, Portland District, 333 SW 1st Ave, Portland OR 97204. Subject: Pre-solicitation notice for Generator Step-up Transformer at the Dalles Dam, Dalles OR, 97058-0564 Proposed solicitation number: W9127N-15-R-0060 Closing response date: approximately 90 days from the date the solicitation is issued Point of Contact: Gary Weir Contracting Officer, 509-527-4624, gary.r.weir@usace.army.mil Description of Requirement: This synopsis is not a request for quotes or proposals. This is a pre-solicitation notice that a solicitation is scheduled to be released via FedBizOpps (www.fbo.gov) in the near future detailing requirements for Generator Step-up Transformer at the Dalles Dam, Dalles OR, 97058-0564. The Dalles Dam is undergoing an upgrade to the existing Step-Up Transformers and will be replacing the existing systems. The project will eventually replace a total of nineteen transformers of various specifications over the course of the next several years. Class II Three-phase GSU Power Transformer: Design, manufacture, and factory test of one three-phase generator step-up (GSU) power transformer rated 175,000/233,333 kVA, 230 kV high-voltage, 13.2 kV low-voltage, Class ODAF/ODAF cooling, for delivery f.o.b. to The Dalles power plant including transformer shipment, hauling, site movement, reassembly and field testing. Class II Single-phase GSU Power Transformers: Design, manufacture, and factory testing of three single-phase generator step-up (GSU) power transformers rated 9,000/12,000 kVA, 115 GrdY/66.395 kV high-voltage, 13.2 kV low-voltage, Class ONAN/ONAF cooling, for delivery f.o.b. to The Dalles power plant including transformer shipment, hauling, site movement, reassembly and field testing. Design, manufacture, and factory testing of three single-phase generator step-up (GSU) power transformers rated 37,800/50,400/63,000 kVA, 115 GrdY/66.395 kV high-voltage, 13.2 kV low-voltage, Class ONAN/ONAF/ONAF cooling, for delivery f.o.b. to The Dalles power plant including transformer shipment, hauling,site movement, reassembly and field testing. Design, manufacture, and factory testing of twelve single-phase generator step-up (GSU) power transformers rated 37,800/50,400/63,000 kVA, 230 GrdY/132.790 kV high-voltage, 13.2 kV low-voltage, Class ONAN/ONAF/ONAF cooling, for delivery f.o.b. to The Dalles power plant including transformer shipment, hauling, site movement, reassembly and field testing. Contract Drawings: The Drawings that accompany the Specifications are a part thereof. One set of full size Contract drawings, maps, and Specifications will be furnished to the Contractor without charge per Section 00700 Contract Clause 252.236-7001, CONTRACT DRAWINGS AND SPECIFICATIONS. Reference publications will not be furnished. Contractor will be expected to immediately check furnished Drawings and notify the Government of any discrepancies. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Set-aside Status: The solicitation is scheduled to be issued as Unrestricted. Conducting Business with the Government: In order for contractors to conduct business with the Department of Defense, the contractor must provide registration information to the System for Award Management Registration (SAM). All Offerors must be SAM registered prior to receiving an award. Registration instructions may be obtained and online registration may be accomplished, at www.sam.gov. By submission of a quote, a vendor acknowledges the requirement to be registered in the SAM database prior to award, during performance, and through final payment of any contract resulting from the solicitation. When available, the solicitation documents for this project will be accessible via FedBizOpps at www.fbo.gov. No CD's or hard copies will be available. Offerors are responsible for checking the referenced page for any update(s) to the Notice. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the document posted at the referenced website.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA57/W9127N-15-R-0060/listing.html)
 
Place of Performance
Address: USACE District, Portland Contracting Division (CECT-NWP), P.O. Box 2946 Portland OR
Zip Code: 97208-2946
 
Record
SN03664293-W 20150313/150311234647-0086ffc0e7bc0ee5d2f0a2f2941feaf9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.