SOURCES SOUGHT
Z -- Replacement of Existing Underground Primary Electrical Pathway, DLA Distribution Susquehanna PA (DDSP), New Cumberland PA 17070
- Notice Date
- 3/11/2015
- Notice Type
- Sources Sought
- NAICS
- 237130
— Power and Communication Line and Related Structures Construction
- Contracting Office
- Defense Logistics Agency, DLA Acquisition Locations, DLA Distribution, J Avenue, DDC J7-AB, Bldg 404, New Cumberland, Pennsylvania, 17070-5001, United States
- ZIP Code
- 17070-5001
- Solicitation Number
- SP330015SourcesSought
- Archive Date
- 4/8/2015
- Point of Contact
- DONNA A KAUTZ, Phone: 717-770-6563
- E-Mail Address
-
donna.kautz@dla.mil
(donna.kautz@dla.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a Sources Sought (SS)/Request for Information (RFI) Notice. DLA Distribution is considering a small business (SB) set-aside for the construction of a new primary electrical pathway to be located at DLA Distribution Susquehanna, New Cumberland, PA (DDSP) 17070 and is seeking SB sources that qualify under North American Classification System (NAICS) code 237130, size standard $36.5M. This notice is provided as information to the marketplace and is an invitation for an expression of interest in the construction services as stated below. This SS/RFI does not constitute a request for a formal quote or proposal. Furthermore, DLA Distribution will not accept any unsolicited proposals in response to this notice. A response to this notice is required by March 24, 2015 at 1:00 PM EST. This notice is for informational and market research purposes only and will be evaluated on this basis. A future set-aside determination may be based on the type and quality of responses received from this notice. Responses are sought only from SB sources that can provide the services described below. Responses received from any company that is not a SB concern will not be considered. All respondents to this notice will be confirmed as a SB potential source through their On-Line Representations and Certifications contained in the System for Award Management (SAM) database. This SS/RFI notice does not commit the Government to contract for the identified services and/or taskings. If a solicitation is released, it will be synopsized on the Federal Business Opportunities (FedBizOpps) website at http://www.fbo.gov/. It is the responsibility of potential respondents to monitor this site for additional information pertaining to this potential future procurement. The information provided in this SS/RFI is subject to change and is not binding on the Government. The release of this notice should not be construed as a commitment or as authorization to incur cost for which reimbursement would be required or sought. Respondents are advised that DLA Distribution will not pay for any information or administrative cost incurred in responding to this notice. In addition, the Government will not entertain any requests to meet individually with a contractor, and will not respond to any telephonic inquiries. Responses to this notice must be received electronically. Paper media will not be accepted or opened. An email response should be sent to donna.kautz@dla.mil. Questions regarding the content of this SS/RFI should be referred to Donna Kautz via above email or at (717) 770-6563. Please be advised that all information received in response to this SS/RFI will be considered procurement sensitive and will be handled accordingly. However, any information the contractor considers to be proprietary pursuant to existing laws and regulations should be marked accordingly on all appropriate pages (FAR 3.104-1(3) & (4)). Description of Work: DLA Distribution has a need to repair by replacement approximately 2,300 linear feet of existing underground primary electrical pathway that originates near a 69KV substation on its New Cumberland, PA site. This project will include all of the necessary labor and material required for the replacement of (2) existing utility poles; the re-routing of associated existing aerial conductors; and the furnishing and installation of the following: (2) sections of 15KV pad mounted switchgear; (12) 15KV cable terminations; (6) precast concrete electrical manholes; approximately 1,100 linear feet of concrete encased electrical duct bank; approximately 1,200 linear feet of precast concrete utility trench; and cable support/racking for the manholes and utility trench. The new underground pathway is generally to be routed in/under grass and adjacent to a paved roadway, but the final route will include (2) roadway crossings. At least (1) lane of the adjacent roadway must remain open for traffic for the duration of the construction project. The scope of this project shall include provisions for traffic control to ensure continuous vehicular travel on the adjacent roadway for the duration of the construction project. The 15KV cable associated with the new electrical pathway is to be Government Furnished, Government Installed. The Contractor installing the new primary electrical pathway shall be responsible for coordinating with the Government regarding the installation and termination of the 15KV cable. As a result of this SS/RFI, DLA Distribution is requesting a technical capabilities statement and past performance references listing at least three construction projects completed within the last five years that are similar in size and scope to the project outlined in the SS/RFI. Response to this SS/RFI should not exceed a total of five pages. Interested SB sources that qualify under the above listed NAICS are asked to submit the following that identifies their capabilities with regard to this notice. As a minimum, any such response must include: 1. Technical Capability: a) Capabilities statement that identifies your company as a qualified construction firm; b) Duns/cage number for your company; c) Those services your company would provide directly and those you would need to provide through a subcontractor or reseller given the work description; d) Statement of your company's intention (affirmative or negative) to submit a proposal for any subsequent acquisition announcement for like or similar services that may be issued within two months from the current date; and e) Company point of contact and phone number for any questions that may arise as a result of this notice. 2) Past Performance References: The Contractor shall provide the following information in their past performance references: a) Point of Contact and phone number for each reference; and b) Past performance projects shall include the following critical elements: i. Excavation and backfill ii. Traffic control iii. Installation of concrete encased duct bank iv. Installation of precast electrical manholes v. Installation of precast utility trench (for electrical cabling) vi. Installation of 15KV switchgear vii. Installation of aerial 15KV conductors viii. Termination of 15KV conductors
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DDC/SP330015SourcesSought/listing.html)
- Place of Performance
- Address: 2001 Mission Drive, New Cumberland, Pennsylvania, 17070, United States
- Zip Code: 17070
- Zip Code: 17070