Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 14, 2015 FBO #4858
SOURCES SOUGHT

81 -- Interim Storage Shield Containers - (Draft)

Notice Date
3/12/2015
 
Notice Type
Sources Sought
 
NAICS
332999 — All Other Miscellaneous Fabricated Metal Product Manufacturing
 
Contracting Office
Department of Energy, CH2M Hill B&W West Valley, LLC, West Valley, 10282 Rock Springs Road, West Valley, New York, 14171-9799
 
ZIP Code
14171-9799
 
Solicitation Number
RFPQ-004851
 
Archive Date
4/10/2015
 
Point of Contact
Chris Avery, Phone: 716-942-4587
 
E-Mail Address
Chris.avery@chbwv.com
(Chris.avery@chbwv.com)
 
Small Business Set-Aside
N/A
 
Description
WV-0150 - Supplier Data Sheet and Business Size Certification Form SOURCES SOUGHT: THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. THIS IS NOT A SOLICITATION AND PROPOSALS ARE NOT BEING REQUESTED AT THIS TIME. THE PURPOSE OF THIS ANNOUNCEMENT IS TO GAIN KNOWLEDGE OF CURRENT MARKET CAPABILITIES. INTERESTED PARTIES SHOULD COMPLETE AND SUBMIT FORM WV-0150, "SUPPLIER DATA SHEET AND BUSINESS SIZE CERTIFICATION FORM" TO THE ADDRESS LISTED BELOW. Any information submitted by respondents to this sources sought synopsis is voluntary and is not to be construed as a commitment by CH2M HILL B&W West Valley, LLC (CHBWV), nor will CHBWV reimburse any costs associated with the submission of information in response to this notice. The proposed scope of work will consist of the following: Design and delivery of cost effective interim storage shield containers for one hundred & forty two (142) high dose radioactive waste drums. Existing containers/designs can be modified to meet the criteria below: Containers: •· Containers must be capable of shielding waste to <200 mR at contact and <100 mR at 1 ft. •· Total container loaded weight must be less than 40,000 lbs. · Container must be able to be stacked 2-high •· Container must be suitable for outdoor storage •· Number of drums in a container is only limited by container physical constraints •· More than one container design may be required and/or modular designs accepted •· Container must fit within a 10 foot-diameter foot print (rectangle or round) •· Container must be capable of being lifted by crane and forklift •· Container shall be top loaded and the lid must be able to be capable of being removed and placed remotely with a 10 ton crane •· Container shall have sufficient clearance to allow the internal drums lids to be placed remotely •· Floor loading of double stacked containers should be less than 2,800 lbs/sq. ft. •· Containers shall be designed such that the maximum critical heat flux on an interior surface shall not exceed 10 kW/m2 when exposed to conditions described in 10 CFR 71.73(c)(4). •· Containers shall be capable of resisting perforation when impacted by a 13,000 pound vehicle travelling at 15 miles per hour or when impacted by a tornado-borne missile identified in the following table : Missile Weight Cross Sectional Area Horizontal Velocity* Max Height Above Ground Timber Plank 4" x 12" x 12' long (dimensions are nominal) 139 lb 0.29 ft 2 85 mph 200 ft Steel Pipe 3" diameter x 10' long 76 lb 0.0155 ft 2 ** 50 mph 100 ft * Vertical velocities are taken as two‑thirds the horizontal missile velocity. Horizontal and vertical velocities should not be combined vectorially. ** Value represents metal area. Waste Drums •· Preliminary Dose Profile Drum Size (D x H) Dose Range in R/hr (circa 2002) Quantity of Drums Primary Gamma 23" x 33" <100 44 Cs-137 23" x 33" 120 to 180 R/hr 15 Cs-137 23" x 33" 120 to 185 R/hr 9 Cs-137 /Co-60 27" x 49" 10 to 20 R/hr 18 Cs-137 23" x 33" 200 to 500R/hr 22 Cs-137/Co-60 23" x 33" 500 to 1000 R/hr 15 Cs-137/Co-60 23" x 33" 1000 to 4000 R/hr 19 Cs-137/Co-60 Total 142 •o •· Max weight #1,000 lbs each •· Dose Rates were measured in 2002 - 2004 Other Requirements: •· All work will be performed under CHBWV approved ASME NQA-1 2008/2009 program or equivalent. • · Delivery of containers expected to begin December 2015. •· Current assumptions require containers are available to support minimum of 4 drums loaded per week. Response Requested: •· Outline technical approach for container and/or availability of existing containers. •· Documentation demonstrating that your firm has the organization, experience, operational controls, technical skills, necessary production, and technical equipment to perform the proposed scope of work •· Documentation demonstrating that your firm has an acceptable Quality Assurance Program in accordance with NQA-1a (2008 with 2009 Addenda).
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/WVNS/WV/RFPQ-004851/listing.html)
 
Place of Performance
Address: CH2M HILL B&W West Valley, LLC (CHBWV), 1028/2 Rock Springs Road, West Valley, New York, 14171, United States
Zip Code: 14171
 
Record
SN03665822-W 20150314/150312234850-b1b5c58ad8c42c625fd7f9510c5228c1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.