SOURCES SOUGHT

Y -- FY 15 Construct Chaff and Flare Storage Facility, Munitions Equipment Storage Facility, and Composites Maintenance Facility, Yokota Air Base, Japan

Notice Date
3/17/2015
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Japan, Attn: CECT-POJ Unit 45010, APO, AP 96338-5010
 
ZIP Code
96338-5010
 
Solicitation Number
W912HV-15-Z-0013
 
Response Due
3/31/2015
 
Archive Date
5/16/2015
 
Point of Contact
Kathleen Mayer, 505-342-3391
 
E-Mail Address
USACE District, Japan
(kathleen.mayer@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
The U.S. Army Corps of Engineers, Japan Engineer District (JED) is performing a market survey for FY 15 Construct Chaff and Flare Storage Facility, Munitions Equipment Storage Facility, and Composites Maintenance Facility, Yokota Air Base, Japan. This announcement constitutes a market survey that is being conducted for planning purposes only and the information received will assist the Government in developing an acquisition method for this project. This notice does not constitute a commitment by the Government for any follow-on announcements, solicitation, or award. Pursuant to Federal Acquisition Regulation (FAR) Part 10, Market Research, the purpose of this notice is to identify sources capable of satisfying the Government's requirement. This survey seeks qualified and capable contractors to submit responses to this notice in order to adequately plan the acquisition. If your company would like to be considered as a potential source for this work, please submit a response adhering to the below submission requirements. PROJECT DESCRIPTION Project Title: FY 15 Construct Chaff and Flare Storage Facility, Munitions Equipment Storage Facility, and Composites Maintenance Facility, Yokota Air Base, Japan Project Location: Fussa, Tokyo, Japan North American Industry Classification System (NAICS) Code is 236220 Project price magnitude is between 100,000,000 YEN and 500,000,000 YEN (utilizing a 100 YEN to 1 U.S. dollar rate) This project will provide a single-story open metal structure with concrete slab, approximately 279 square meters in size, for storage of chaff and flares. This facility will be located to the southwest of the intersection of Kilo and Golf Taxiways and northeast of Building 1310. Chain length, FE-6, security fencing will be required, enclosing the facility. Two asphalt drives will be provided from the existing asphalt road, such that both sides of the facility will be accessible. No new storm drainage will be required for the facility. There is no water or sewer provided in the project. Approximately 485-meters of conduit will be installed to the site to support exterior primary power. A 75KVA transformer will be provided to serve the Chaff and Flare Storage Facility and Munitions Equipment Storage Facility. No exterior lighting will be provided. Interior lighting will consist of suspended fluorescent fixtures and emergency lighting will be provided. A fire detection and alarm system will be installed in the facility. There is no mechanical work in this project. This project will provide a single story enclosed metal structure with concrete slab, approximately 193 square meters in size, for storage of storage of 1.4 and 1.3 munitions. The exterior walls will be constructed of metal panels over batt insulation. This facility will be located to the southwest of the intersection of Kilo and Golf Taxiways and northeast of Building 1310, across the street from the new Chaff and Flare Storage Facility. A chain length, FE-6, security fencing will be installed, enclosing the facility. Two asphalt drives will be provided from the existing asphalt road, such that both sides of the facility will be accessible. No new storm drainage will be required for the facility. There is no water or sewer provided in the project. Power will be provided from the transformer installed at the Chaff and Flare Storage Facility. No exterior lighting will be provided. Interior lighting will consist of suspended fluorescent fixtures and emergency lighting will be provided. A fire detection and alarm system will be installed in the facility. There is no mechanical work in this project. The Composites Facility will be located at the northwest corner of existing Building 907. The project will include demolition of existing parking lot, which consists of both asphalt and concrete pavements. New site work will include a minor amount of new paint markings in the parking lot and installation of new heavy-duty concrete pavement around the facility. No storm drainage will be provided in this project. Water and sewer will be provided from existing base systems. No additional fire hydrants are required for the project. Due to the size of the project, a fire suppression system is not required. New plumbing work and fixtures will be installed for the locker area, consisting of the showers and restroom. A ductless split unit will be provided for HVAC heating and cooling systems. Secondary power connection and transformer will be provided from the existing primary line. Suspended fluorescent fixtures will be installed, as well as, emergency lighting. A fire detection and alarm system will be installed in the facility. This market survey is intended for local sources only. Local sources are those sources physically located and licensed to conduct business in Japan. Firms interested and capable of performing this work are highly encouraged to submit a response. SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS MARKET SURVEY (1) Name of your company, address, phone number, email, and point of contact. (2) A statement of intent from your company, that should this project be formally solicited, you will submit a price proposal. (3) Letter from your insurance (surety) company stating that your firm has adequate bonding capacity within the project magnitude of 100,000,000 YEN and 500,000,000 YEN (utilizing a 100 YEN to 1 U.S. dollar rate) (4) Statement of capability from your company, identifying applicable skills, experience, knowledge, past performance, and equipment required to perform this project. Limit this statement of capability to no more than five (5) pages in length. The type of solicitation issued and the manner of advertisement may depend on the responses to this market survey. If you do not intend on submitting a proposal for this work if it is formally advertised, please do not submit a response to this market survey. Point of Contact(s): Ms. Kathleen Mayer at kathleen.mayer@usace.army.mil. PLEASE SEND YOUR RESPONSES VIA EMAIL. All responses must be received before March 31, 2015 at 04:00 p.m. Japan Standard Time. Any responses received after this deadline will not be used in this market research.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA79/W912HV-15-Z-0013/listing.html)
 
Place of Performance
Address: USACE District, Japan Attn: CECT-POJ Unit 45010, APO AP
Zip Code: 96338-5010
 
Record
SN03671096-W 20150319/150318000129-a7991972eef191ea497b17eb6ae16157 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.