Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 22, 2015 FBO #4866
MODIFICATION

Z -- ADAL Two Existing Hangars to Accommodate the New KC46 Tanker - Amendment 2

Notice Date
3/20/2015
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USPFO for New Hampshire, 1 Minutemen Way, Concord, NH 03301-5652
 
ZIP Code
03301-5652
 
Solicitation Number
W912TF15R0500
 
Response Due
3/11/2015
 
Archive Date
4/9/2015
 
Point of Contact
Scott Ballweg, Phone: 603-715-3670
 
E-Mail Address
scott.l.ballweg.civ@mail.mil
(scott.l.ballweg.civ@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
011400 - Work Restrictions Rev 031715 Maint Hangar 011400 - Work Restrictions Rev 031715 Fuel Cell 254- E-603 - PANEL SCHEDULES 254- E-503 - ELECTRICAL DETAILS 254- E-108 - NORTH HANGAR AREA POWER & SYSTEMS PLAN REV 254- 263543 - 400 HZ Solid State Frequency Converter 253- E-601 - SINGLE LINE DIAGRAM 253- E-108 - NORTH HANGAR AREA POWER & SYSTEMS PLAN REV 253- 263543 - 400 HZ Solid State Frequency Converter SECTION 087100 - DOOR HARDWARE-Rev RFI answers_FBO posting 3.20.15 W912TF-15-R-0500-0003_Amendment 3 Document Type: Pre-Solicitation Notice Solicitation Number: W912TF-15-R-0500 Posted Date: December 23, 2014 Original Response Date: March 11, 2015 Current Response Date: April 1, 2015 Original Archive Date: June 21, 2015 Classification Code: Y-Construction of Structures and Facilities Set Aside: Small Business Classification Code Y-Construction of Structures and facilities NAICS Code: 236220- Commercial and Institutional Building Construction The USPFO for New Hampshire intends to issue a Request for Proposal (RFP) to award a single firm fixed price contract for services, non personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances and supervision necessary to perform and complete a functional installation of Two (2) existing KC135 Hangars at Pease ANGB, NH. SZCQ139901, KC-46A ADAL Fuel Cell Building 253 primarily consists of a hangar bay addition measuring approximately 193' by 111' in plan, with a height of approximately 85', and the construction of aircraft maintenance shops within the exiting hangar structure. The work includes the following principal elements: Site work, including utility work and paving; general building work, including selective demolition, hangar slab on grade floor, steel framing, fall protection, siding, hangar doors, roof, snow guards, interior walls and doors, overhead doors, casework, finishes, HVAC, plumbing, HEF fire protection system, electrical and communications work. The following OPTIONs may apply: 1) Remove and Replace Standing Seam Metal Roof. 2) Reconstruct Parking Lot. 3) LED Lighting in Hangar. 4) Parking Lot Lighting. The second hangar: SZCQ139904, KC-46A ADAL Maintenance Hangar Building 254 primarily consists of demolition of a previous hangar bay addition measuring approximately 162' by 53' in plan, with a height of 61', construction of a new hangar bay addition measuring approximately 193' by 111' in plan, with a height of approximately 85', and the renovation of aircraft maintenance shops within the existing structure. The work includes the following principal elements: Site work, including utility work and paving; general building, including selective demolition, hangar slab on grade floor, steel framing, fall protection, siding, hangar doors, roof, snow guards, interior walls and doors, overhead doors, casework, finishes, HVAC, plumbing, HEF fire protection system, electrical and communications work. The following OPTIONs may apply: 1) Remove and Replace Membrane Roof. 2) Remove and Replace Standing Seam Metal Roof. 3) Reconstruct Parking Lot. 4) LED Lighting in Hangar. 5) Replace Office Doors. 6) Hangar Slab Aggregate Base Materials. Alteration and repairs to Hangar Building 253 and Hangar Building 254 will run concurrently. The hangar bay in building 253 must be 100% usable by the Government before effort of work associated with the hangar bay in building 254 can be started. The work outside the hangar bay in building 254 can be started simultaneously as the work in building 253. This yields an overall contract duration of 30 months. Brand name requirements for this project are: Schneider Electric TAC I/A Series controllers, Advantor Security Systems (Sole Source), Simplex Fire Alarm, and Ansul Orifice plates. J&A will be posted with solicitation. Magnitude of construction is between $25,000,000 and $100,000,000. Period of Performance/Contract Completion time is 900 days to include inspection and punchlist. The North American Industry Classification System (NAICS) code for this work is 236220. The small business size standard is $36.5 million. Your attention is directed to FAR CLAUSE 52.219-14 (b)(4) LIMITATIONS ON SUBCONTRACTING which states quote mark By submission of an offer and execution of a contract, the Offeror /Contractor agrees that in performance of the contract the concern will perform at least 15 percent of the cost of the contract, not including the cost of materials, with its own employees quote mark applies to this project. The tentative date for issuing the solicitation is on-or-about 12 January 2015. The tentative date for the pre-proposal conference is on-or-about 21 January 2015, 10:00 AM EST at Pease ANGB NH, 302 Newmarket Street, Portsmouth, NH. Interested contractors are encouraged to attend and shall follow conference registration and base access requirements shown in the solicitation. A site visit will follow the pre-proposal conference. All questions for the pre-proposal conference must be submitted by 20 January 2015 via email (preferred) to Regina Rockwood at Regina.m.rockwood.mil@mail.mil AND Scott Ballweg at scott.l.ballweg.civ@mail.mil The solicitation closing date is scheduled for on-or about 20 March 2015. Actual dates and times will be identified in the solicitation. The source selection process will be conducted in accordance with FAR Part 15.3 and DFARS Part 215.3, source selection procedures. Evaluation factors include Technical, Past Performance and Price. The Government intends to award without discussions. Interested offerors must be registered in the System for Award Management (SAM). To register go to: www.sam.gov. You will need your DUNS number register. Instructions for registering are on the web page. The solicitation and associated information and the plans and specifications will be available only from the Federal Business Opportunities (FedBizOpps) website online at www.fbo.gov. FedBizOpps is a web-based dissemination tool designed to safeguard acquisition-related information for all Federal agencies. Interested bidders/offerors must register with FedBizOpps before accessing the system. FedBizOpps registration requires the following information: 1) Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN), 2) DUNS Number and CAGE Code, 3) Telephone Number, 4) Email address. Registration instructions can be found on the FedBizOpps website at https://www.fbo.gov/downloads/FBO_Vendor_Guide.pdf. (Please note the registration for access to the secure site takes approximately 15 business days. PLAN ACCORDINGLY.) Reference paragraph 4.7 of the Vendor Guide for instructions to obtain a MPIN to retrieve the specification and drawing documents. Contractors who do not already have a MPIN are advised that the normal processing is 7 to 15 business days to obtain a MPIN password that will give them access to the plans and specifications, which are located in the controlled access location on FBO. See video in vendor guide at 3.3 on advanced functions for other information. Bidders/offerors who have registered with FedBizOpps must access the data for this solicitation with their MPIN. Bidders/Offerors cannot log into the FedBizOpps home page and search for data. This solicitation is not a competitive invitation for bid and there will not be a formal public bid opening. DISCLAIMER: The official plans and specifications are located on the official government webpage and the Government is not liable for information furnished by any other source. Amendments, if/when issued will be posted to https://www.fbo.gov/ for electronic downloading. This will normally be the only method of distributing amendments prior to closing; therefore, it is the offerors responsibility to check the website periodically for any amendments to the solicitation. Websites are occasionally inaccessible due to various reasons. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the documents posted on the referenced web pages. The Government will not issue paper copies or CDs. All inquiries must be in writing, preferable via email to the persons specified in the solicitation. All answers will be provided in writing via posting to the web. Place of performance is Pease Air National Guard Base, Newington, NH 03803 DISCLAIMER: The official plans and specification are located on the official government web page https://www.fbo.gov/ and the Government is not liable for information furnished by any other source. Amendments, if/when issued will be posted to the FedBizOpps.gov or fbo.gov for electronic downloading. This will normally be the only method of distributing amendments prior to closing; therefore, it is the offerors responsibility to check the website periodically for any amendments to the solicitation. Websites are occasionally inaccessible due to various reasons. The Government is not responsible for any loss of Internet connectivity or for an offerors inability to access the documents posted on the referenced web pages. The Government will not issue paper copies.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA27/W912TF15R0500/listing.html)
 
Place of Performance
Address: USPFO for New Hampshire 302 Newmarket St. Newington NH
Zip Code: 03801-2886
 
Record
SN03674333-W 20150322/150320234551-4b6763856132d3b69a2c48deafabf6e3 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.