Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 02, 2015 FBO #4877
AWARD

Y -- The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for FY 12 2-Bay Hangar / AMU (bldg. 4610) and MRSP Warehouse (bldg. 4616).

Notice Date
3/31/2015
 
Notice Type
Award Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Albuquerque, CESPA-CT, 4101 Jefferson Plaza NE, Albuquerque, NM 87109-3435
 
ZIP Code
87109-3435
 
Solicitation Number
W912PP-15-P-0016
 
Archive Date
4/30/2015
 
Point of Contact
Glenda Kohlieber, 575-652-4135
 
E-Mail Address
USACE District, Albuquerque
(glenda.d.kohlieber@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W912PP-15-P-0016
 
Award Date
3/31/2015
 
Awardee
NJM, INC. (078362133) <br> 8835 GREAVES LN <br> SCHERTZ, TX 78154
 
Award Amount
$49,570.00
 
Line Number
0001
 
Description
This contract action was accomplished using other than competitive procedures because a statute exists that expressly authorizes or requires that the acquisition be made from a specific source or through another agency (FAR 6.302-5); specifically, Sole source awards under the 8(a) Program. Per FAR 6.302-5 a J&A is not required for this award. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for FY 12 2-Bay Hangar / AMU (bldg. 4610) and MRSP Warehouse (bldg. 4616). The work shall include requirements listed in paragraph 2, specific requirements. a.In the FY-12 Two Bay Hangar / AMU (bldg. 4610) reverse cipher lock from the exterior side of door 171 (Area C). b.In the FY-12 Two-Bay Hanger / AMU (bldg. 4610) add overhead lockabel rollup door over window counter in tool room. Door operation must be from room 118 to keep areas secure (Area C) c.In the MRSP Warehouse (bldg. 4616), provide changes to double entry doors W100 (A) and W101 (A) to allow unobstructed and automatic opening of doors to enter the vestibule (W100) and customer service (W101) areas. Automatic door opening system cannot disrupt function of the entry key pad control system on door W100. 1.Hardware Set 22: Pair Doors W101A (Interior Vestibule Doors) a.Remove existing door closers and return to Government. b.Furnish and install one (1) new LCN 9550 Series Auto Opener, push side mount, with brackets, spacers, and plates as required, dark bronze anodized finish. Connect through wall to new power source above Vestibule ceiling. Refer to power requirements description below. c.Furnish and install one (1) new LCN Actuator 8310-818T, surface mounted on the west door jamb. Connect to Auto Opener. There will not be an actuator in the Vestibule.1.Hardware Set 22: Pair Doors W101A (Interior Vestibule Doors) a.Remove existing door closers and return to Government. b.Furnish and install one (1) new LCN 9550 Series Auto Opener, push side mount, with brackets, spacers, and plates as required, dark bronze anodized finish. Connect through wall to new power source above Vestibule ceiling. Refer to power requirements description below. c.Furnish and install one (1) new LCN Actuator 8310-818T, surface mounted on the west door jamb. Connect to Auto Opener. There will not be an actuator in the Vestibule. 2.Hardware set 23: Pair Doors W100A (Exterior Vestibule Doors) a.Remove existing door closer on west (RHR) leaf and return to Government. b.Furnish and install one (1) new LCN 9540 Series Auto Opener, push side mount, with brackets, spacers, and plates as required, dark bronze anodized finish. Connect through aluminum frame and wall to new power source above Vestibule ceiling. Refer to power requirements description below. c.Furnish and install one (1) new LCN Actuator 8310-818T, surface mounted on the west door jamb. Connect to Auto Opener. There will not be an actuator on the exterior of the building. d.Remove existing Panic Device strike on center mullion for west (RHR) leaf and return to Government. e.Furnish and install one (1) new Von Duprin 6300 Electric Strike on center mullion and connect wiring to Power Supply below. Provide plug in wire at top of mullion to disconnect strike when mullion is removed. f.Furnish and install one (1) new Von Duprin Power Supply PS902 above Vestibule ceiling and connect to new power source. Refer to power requirements description below. g.Interconnect the Electric Strike with the Auto Opener Actuator such that when the Actuator is depressed, the Electric Strike will open and the Auto Opener will open the door. When the door closes, it will re-latch. 3.Power Requirements for Vestibule doors: a.Provide power for (3) door-operator power supplies and one (1) electric strike power supply in Vestibule W100 from Panel GPW in Electrical Room 122, spare circuit #59.b.Provide junction box above ceiling in Vestibule W100 with quote mark conduit, two (2) #12 and one (1) #12 E.G. routed back to Panel GPW in Electrical Room 122.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA47/Awards/W912PP-15-P-0016.html)
 
Record
SN03684428-W 20150402/150331235243-87b4a9e04878262fad63119d05c552fc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.