Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 12, 2015 FBO #4887
MODIFICATION

58 -- AM AND FM TRANSMITTERS - Amendment 1

Notice Date
4/10/2015
 
Notice Type
Modification/Amendment
 
NAICS
334220 — Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
 
Contracting Office
Other Defense Agencies, Defense Media Activity, DMA Acquisition and Procurement CA, 23755 Z Street, Riverside, California, 92518-2031, United States
 
ZIP Code
92518-2031
 
Solicitation Number
HQ002850540001
 
Point of Contact
Claudio T. Casupang, Phone: (951) 413-2381, Susan M. Madrid, Phone: 951-413-2371
 
E-Mail Address
claudio.t.casupang2.civ@mail.mil, susan.m.madrid.civ@mail.mil
(claudio.t.casupang2.civ@mail.mil, susan.m.madrid.civ@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
AMMENDMENT 001 COMBINED SYNOPSIS/SOLICITATION: HQ002850540001 Title: AM AND FM TRANSMITERS Description(s): COMBINED SYNOPSIS/SOLICITATION WITH AMMENDMENT 001 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This is a Brand Name Procurement or equal - see attached justification and description of the items and the salient characteristics. a. Solicitation Number HQ002850490131 is being issued as a Request for Quotation (RFQ) and incorporates the following with the word "quoter" substituted for "offeror". b. Provisions and clauses are those in effect through both Federal Acquisition Circular 2005-80, effective 2 March 2015 and DFARS Change Notice 20150406 c. This procurement is brand name; associated with NAICS Code 334220 with a size standard of 750 employees. This procurement is set aside for Small Business. d. Description: THESE ITEMS ARE BRAND NAME OR EQUAL; SEE THE ATTACHED SALIENT CHARACTERISTIC. FILL IN ALL UNIT PRICE AND TOTALS BELOW. FOR CONSIDERATION ENSURE THAT THE FREIGHT COSTS ARE ABSORBED IN UNIT PRICE CLIN. CLIN 0001: 100W FM 107.9MHz, Main/Alt configuration DESCRIPTION: 1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration 2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase 3. Power Factor: 0.90 or better 4. Output Impedance: 50 ohms 5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations 6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 7. Analog, composite, and AES inputs. a. AES Impedance: 100-110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 8. Stereo generator 9. Front Panel Control 10. Automatic transmitter switcher 11. RF switch 12. RF output Low Pass Filter 13. Rack cabinets 14. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 107.9MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0002: 2000W FM 101.7MHz, Main/Alt configuration DESCRIPTION: 1. Two 1000-5000W FM Digital transmitters/exciters in Main/Alternate configuration 2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase 3. Power Factor: 0.90 or better 4. Output Impedance: 50 ohms 5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations 6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 7. Analog, composite, and AES inputs. a. AES Impedance: 100-110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 8. Stereo generator 9. Front Panel Control 10. Automatic transmitter switcher 11. RF switch 12. RF output Low Pass Filter 13. Rack cabinets 14. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 101.7MHz UNIT PRICE @ _____________ x 1 $__________________ CLIN 0003: 250W FM 106.2MHz, Main/Alt configuration DESCRIPTION: 1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration 2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase 3. Power Factor: 0.90 or better 4. Output Impedance: 50 ohms 5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations 6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 7. Analog, composite, and AES inputs. a. AES Impedance: 100-110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 8. Stereo generator 9. Front Panel Control 10. Automatic transmitter switcher 11. RF switch 12. RF output Low Pass Filter 13. Rack cabinets 14. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 106.2MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0004: 250W FM 106.5MHz, Main/Alt configuration DESCRIPTION: 1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration 2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase 3. Power Factor: 0.90 or better 4. Output Impedance: 50 ohms 5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations 6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 7. Analog, composite, and AES inputs. a. AES Impedance: 100-110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 8. Stereo generator 9. Front Panel Control 10. Automatic transmitter switcher 11. RF switch 12. RF output Low Pass Filter 13. Rack cabinets 14. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 106.5MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0005: 250W FM 107.3MHz, Main/Alt configuration DESCRIPTION: 1. Two 100W - 300W FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 107.3MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0006: 5000W FM 105.9MHz, Main/Alt configuration DESCRIPTION: 1. Two 5000W FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 105.9MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0007: 5000W FM 106.0MHz, Main/Alt configuration DESCRIPTION: 1. Two 5000W FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 106.0MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0008: 500W FM 106.5MHz, Main/Alt configuration DESCRIPTION: 1. Two 500W-1KW FM Digital transmitters/exciters in Main/Alternate configuration 2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase 3. Power Factor: 0.90 or better 4. Output Impedance: 50 ohms 5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations 6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 7. Analog, composite, and AES inputs. a. AES Impedance: 100-110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 8. Stereo generator 9. Front Panel Control 10. Automatic transmitter switcher 11. RF switch 12. RF output Low Pass Filter 13. Rack cabinets 14. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 106.5MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0009: 500W FM 102.1MHz, Main/Alt configuration DESCRIPTION: 1. Two 500W-1KW FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 102.1MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0010: 500W FM 103.1MHz, Main/Alt configuration DESCRIPTION: 1. Two 500W-1KW FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 103.1MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0011: 1kW AM 1340KHz, Main/Alt configuration DESCRIPTION: 1. Two 1KW AM transmitters in Main/Alternate configuration 2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase 3. Efficiency: 60% or better 4. Power Factor: 0.70 or better 5. Output Impedance: 50 ohms 6. Redundant Power Supplies 7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 10. Analog, composite a. Impedance: 600 Ohm Balanced 11. Automatic transmitter switcher 12. Front Panel Metering 13. RF switch. 14. Rack cabinets 15. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 1340KHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0012: 1kW AM 1575KHz, Main/Alt configuration DESCRIPTION: 1. Two 1KW AM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 60% or better 4. Power Factor: 0.70 or better 5. Output Impedance: 50 ohms 6. Redundant Power Supplies 7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 10. Analog, composite a. Impedance: 600 Ohm Balanced 11. Automatic transmitter switcher 12. Front Panel Metering 13. RF switch. 14. Rack cabinets 15. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 1575KHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0013: 1kW AM 1575KHz, Main/Alt configuration 1. DESCRIPTION: Two 1KW AM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 60% or better 4. Power Factor: 0.70 or better 5. Output Impedance: 50 ohms 6. Redundant Power Supplies 7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 10. Analog, composite a. Impedance: 600 Ohm Balanced 11. Automatic transmitter switcher 12. Front Panel Metering 13. RF switch. 14. Rack cabinets 15. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 1575KHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0014: 1kW FM 89.1MHz, Main/Alt configuration DESCRIPTION: 1. Two 1KW FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 89.1MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0015: 1kW AM 1575KHz, Main/Alt configuration DESCRIPTION: 1. Two 1KW AM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 60% or better 4. Power Factor: 0.70 or better 5. Output Impedance: 50 ohms 6. Redundant Power Supplies 7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 10. Analog, composite a. Impedance: 600 Ohm Balanced 11. Automatic transmitter switcher 12. Front Panel Metering 13. RF switch. 14. Rack cabinets 15. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 1575KHz UNIT PRICE @ _____________ x 1 EA =$__________________ CLIN 0016: 10kW AM 648KHz, Main/Alt configuration DESCRIPTION: 1. Two 1KW AM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 60% or better 4. Power Factor: 0.70 or better 5. Output Impedance: 50 ohms 6. Redundant Power Supplies 7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 10. Analog, composite a. Impedance: 600 Ohm Balanced 11. Automatic transmitter switcher 12. Front Panel Metering 13. RF switch. 14. Rack cabinets 15. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 648KHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0017: 250W FM 99.1MHz, Main/Alt configuration DESCRIPTION: 1. Two 100-300W FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 99.1MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0018: 250W FM 101.9MHz, Main/Alt configuration DESCRIPTION: 1. Two 100-300W FM transmitters in Main/Alternate configuration 2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase 3. Efficiency: 50% or better 4. Power Factor: 0.90 or better 5. Output Impedance: 50 ohms 6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations. 7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements 8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions 9. Analog, composite, and AES inputs a. AES Impedance: 110 Ohm balanced b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced 10. Stereo generator 11. IP Connectivity 12. Front Panel Control and Metering 13. Automatic transmitter switcher 14. RF switch 15. Low Pass Filter 16. Rack cabinets 17. Remote Control Unit that is GSM (cellular) Modem Compatible Frequency 101.9MHz UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0019: Antenna Tuning Unit DESCRIPTION: 1. Transmitter Frequency is 1575KHz 2. Transmitter Power is 1000W 3. The measured impedance is 87 +j60 ohms 4. The tower height is 45 meters self-supporting type with a triangular cross section 5. The tower Face Width is proportional with a 5.6 meters triangular section at the bottom and a 70 centimeters top triangular section. 6. The tower is shunt fed. (Folded Type Down Lead Antenna or Folded Unipole) 7. The unipole skirt kit height on the tower is 45 meters 8. The level of the lower shorting ring is 20m 9. The tower has 9 skirt wires, 22 square gauge, straight off the face centers 10. The standoff distance of the wires from the tower is 2.5m diameter at the top and 5m at the bottom 11. The shorting stub wires level is 40m L1, 20m L2 shorting ring 12. No specific existing restrictions for isolation 13. The Input Transmission line impedance is 50ohms using RG-218/U(RG-17A/U) as a transmission line 14. The connection type and size is open wire 15. The required RF current metering is a Toroidal style out RF current meter 16. The current transmission line length from transmitter output to ATU input is ~60m 17. There is a need to use the existing mounting steel plate (400mmx400mmx4.5mm) and cable feed. UNIT PRICE @ _____________ x 1 EA = $__________________ CLIN 0020: Antenna Tuning Unit DESCRIPTION: Transmitter Frequency: 1440 KHz 2. Transmitter Power: 5000W 3. The measured impedance: Not at This Time 4. The tower height is 180 ft. guyed tower type with a triangular cross section 5. The tower Face Width is 18 inches 6. The tower is Series Fed Base Isolated. 7. Restrictions for isolation: See ATTACHED picture UNIT PRICE @ _____________ x 1 EA = $__________________ TOTAL PRICE FOR THIS QUOTE $________________________________________ FOR CONSIDERATION ENSURE THAT THE FREIGHT COSTS ARE ABSORBED IN UNIT PRICE CLIN. e. Delivery and acceptance will be made at location: FOB DESTINATION DEFENSE MEDIA ACTIVITY 14855 6TH Street, Bldg 2725 Riverside, CA 92518-2221 52.0100-4000 RECEIVING HOURS FOR DELIVERIES (DMC)(Jun 2007) Material for delivery will be accepted at the receiving activity between 0730 and 1430 hours only, daily except Saturday, Sunday and Federal holidays. Carriers or deliveries arriving after 1430 hours will not be off-loaded or accepted until the following workday. f. FAR Provision 52.212-1 (Instructions to Offerors - Commercial Items) (APR 2014) applies to this acquisition. Para (k) requires current registration in SAM at https://www.sam.gov. g. FAR 52.212-2, Evaluation - Commercial Items (JAN 1999) applies with the following insertion at paragraph (a): Technical and Price; with award being made to the lowest priced responsible, responsive quote meeting the requirements of this combined synopsis/solicitation. Technical evaluation will be based on the products provided meeting the minimum salient characteristics and on the Offeror's certification that it is a Manufacturer Authorized Partner and that it has the certification/ specialization level required by the manufacturer to support both the product sale and product pricing, in accordance with the applicable manufacturer certification/ specialization requirements. It is the responsibility of all interested offerors to review this site frequently for any updates/ amendments that may occur during the solicitation process. The posting of this requirement does not obligate the Government to award a contract nor does it obligate the Government to pay for any proposal preparation costs. The Government reserves the right to cancel this procurement/ solicitation either before or after the solicitation closing date, with no obligation to the offeror by the Government. The Government will issue a contract to the responsible, responsive offeror, with acceptable past performance, submitting the lowest price. All prospective contractors must be registered in the System for Award Management in order to be eligible for contract award. For registration, go to www.sam.gov and follow the instructions. h. Quotations must include a completed copy of FAR Provision 52.212-3 (Offeror Representations and Certifications - Commercial Items) (OCT 2014). Electronic submission is located at https://www.sam.gov. i. This order will include the following referenced clauses which may be accessed electronically at http://farsite.hill.af.mil. FAR 52.203-3 Gratuities (APR 1994) FAR 52.203-7 Anti-Kickback Procedures (MAY 2014) FAR 52.212-4 Contract Terms and Conditions-Commercial Items (MAY 2014) FAR 52.212-5 Contract Terms and Conditions Required to Implement Statues Or Executive Orders-Commercial Items (OCT 2014) FAR 52.222-50 -- Combating Trafficking in Persons. (FEB 2009) FAR 52.225-5 Trade Agreements (Nov 2013) FAR 52.225-6 Trade Agreements Certificate (MAY 2014) FAR 52.225-18 Place of Manufacture (SEP 2006) FAR 52.232-33 Payment by Electronic Funds-System for Award Management (JUL 2013) FAR 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998) FAR 52.252-2 Clauses Incorporated by Reference (FEB 1998) DFARS 252.204-7004 Alt A (System for Award Management (FEB 2014) DFARS 252.204-7007 Alternate A, Annual Representations and Certification (AUG 2014) DFARS 252.211-7003 Iten Unique Identification and Valuation (DEC 2013) DFARS 252.232-7003 Electronic Submission of Payment Request (JUN 2012) DFARS 252.232-7006 Wide Area Work Flow Payment Instructions (MAY 2013) DFARS 252.246-7000 Material Inspection and Receiving Report (MAR 2008) DEFARS 252.204-7014 Limitations on the Use or Disclosure of Information by Litigation Support Contractors DFARS 252.204-7012 Safeguarding of Unclassified Controlled Technical Information DFARS 252.203-7098 Prohibition On Contracting With Entities That Require Certain Internal Confidentiality Agreements-Representation (Deviation 2015-O0010) (Feb 2015) DFARS 252.203-7999 PROHIBITION ON CONTRACTING WITH ENTITIES THAT REQUIRE CERTAIN INTERNAL CONFIDENTIALITY AGREEMENTS (DEVIATION 2015-O0010)(FEB 2015) Applicable FAR and DFARS clauses required by regulations, in addition to Local DMC clauses, 52.0100-4028 (Contract Contact Information) (DMC) (JUN 2005) and 52.0100-4094 (Marking Instructions for All Items to Include Drop Ship and Direct Shipment) (JUN 2006) will be included. 252.209-7992 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law­ Fiscal Year 2015 Appropriations. (DEVIATION 2015-OO00005) (DEC 2014) (a) In accordance with sections 744 and 745 of Division E, Title VII, of the Consolidated and Further Continuing Appropriations Act, 2015 (Pub. L. 113-235), none of the funds made available by this or any other Act may be used to enter into a contract with any corporation that- (1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless the agency has considered suspension or debarment of the corporation and made a determination that this further action is not necessary to protect the interests of the Government; or (2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless the agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government. (b) The Offeror represents that- (1) It is [] is not [] a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, (2) It is [] is not [] a corporation that was convicted of a felony criminal violation under a Federal law within the preceding 24 months. (End of Provision) Enterprise-wide Contractor Manpower Reporting Application Authority: (Office of the Secretary of Defense Memorandum, "Enterprise-wide Contractor Reporting Application" November 12, 2012 and United States Code, Title 10, Sections 235 and 233a) The contractor shall report All Contractor labor hours (including subcontractor labor hours) required for performance of services provided under this contract for the Defense Media Activity via a secure data collection site. The contractor is required to completely fill in all required data fields using the following web address: http://www.ecmra.mil/ Reporting inputs will be for the labor executed during the period of performance during each Government fiscal year (FY), which runs October 1 through September 30. While inputs may be reported any time during the FY, all data shall be reported no later than October 31 of each calendar year, beginning with 2013. Contractors may direct questions to the help desk at help desk at: http://www.ecmra.mil/ j. QUOTATIONS ARE DUE BY 12:00AM PACIFIC STANDARD TIME ON 30 April 2015 IN ORDER TO BE CONSIDERED. Send quotation responses to Claudio Casupang at claudio.t.casupang2.civ@mail.mil. On the Subject line of the e-mail insert "QUOTE HQ002850490131" to expedite identification of your quote. For assistance or questions about this announcement may be telephonically addressed at (951) 413-2381. PLEASE NOTE: Due to technical issues email and fax may not result in your quotation arriving before the cut-off time so please allow extra time if you're sending your quote via electronic means. Primary Point of Contact: Claudio T. Casupang, Contract Specialist claudio.t.casupang2.civ@mail.mil Phone: 9514132381 Secondary Point of Contact: Susan M. Madrid, Contracting Officer susan.m.madrid@mail.mil Phone: 951-413-2371 Fax: 951-413-2432 Contracting Office Address: DMA -CONTRACTING 23755 Z Street Riverside, California 92518-2031 Vendor's Name ______________________________________ Vendor's Address: ______________________________________ ______________________________________ ______________________________________ Phone Number: _____________________________________________ e-mail address: _____________________________________________
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/26679bc70e517b25901aae6916eaf0eb)
 
Place of Performance
Address: DEFENSE MEDIA ACTIVITY, 14855 6TH STREET, BLDG 2725, RIVERSIDE, California, 92518-2221, United States
Zip Code: 92518-2221
 
Record
SN03696328-W 20150412/150410234719-26679bc70e517b25901aae6916eaf0eb (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.