Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 25, 2015 FBO #4900
SOLICITATION NOTICE

72 -- Laboratory Furniture

Notice Date
4/23/2015
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
337127 — Institutional Furniture Manufacturing
 
Contracting Office
US Army Medical Research Acquisition Activity, ATTN: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014
 
ZIP Code
21702-5014
 
Solicitation Number
W81XWH15T0131
 
Response Due
5/15/2015
 
Archive Date
6/22/2015
 
Point of Contact
Robbie Johnson, 301-619-2346
 
E-Mail Address
US Army Medical Research Acquisition Activity
(robbie.s.johnson6.mil@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The laboratory division requires several Chromatography/Mass Spectrometry benches to support their operations. See full requirements under the Additional Info heading(Additional documentation link). Minimum Essential Characteristics Brand Name or Equal 1. Requirement: Mobile benches to support Waters Acquity UPC2 System with Xevo TQD IVD (see Attachment Drawing A for Diagram) a. Benches must be able to accommodate the following specifications: i. Instrument table with minimum measurements of 72in wide by 42in deep by 37in high (maximum measurements can be no more than a total of 5 in larger across all dimensions) with a chemical resistant laminate work surface (min 72in wide by 42in deep) and steel frame with an open well sized to accommodate a Peak Scientific NM32LA nitrogen generator (Instrument specs: 23.6in wide x 29.5in deep x 28in high; note that open well must be large enough to accommodate wiring behind and mobility of unit(approx. 2 to 3 in around instrument) is required. ii. The table must include a noise suppression module to house a single Sogevac SV40 BI vacuum pump on a slide-out pump shelf and be equipped with an oil drip pan, mounted shock absorbers, and 2 (two) exhaust fans fitted with external ducting collars. iii.A drawer bank with three full extension lab drawers and one pull-out wiring shelf must be housed below the table surface. iv.Adjustable support arms for a 24 quote mark LCD/Flat screen monitor and keyboard must also be mountable to the table. v.An industrial surge suppressor must also be mounted on the rear of the table so as not to interfere with the work surface area. vi.New equipment only is being requested. Any old or refurbished items will not be acceptable. b.Specifications for Waters Acquity UPC2 System with Xevo TQD IVD (Benches will support this system): ***See table on Minimum Essential Characteristics document by clicking Additional documentation link under Additional info heading*** 2.Requirement: Mobile benches to support Waters Prep 15 SFC system with 2767 Sample Manager and 3100 Mass Detector (see Attachment Drawing B for Diagram) a.Benches must be able to accommodate the following specifications: i.Instrument table with minimum dimensions of 96 in wide by 34 in deep by 37 in high (maximum measurements can be no more than a total of 5 in larger across all dimensions) with a chemical resistant laminate work surface (min 96 in wide by 34 in deep; note that surface does not have to be one complete piece but must be no more than 2 (two) separate pieces making up the required surface area one of which must have minimum dimensions of 60 in wide by 37 in deep) and steel frame with an open well sized to accommodate a Peak Scientific NM32LA nitrogen generator (Instrument specs: 23.6in wide x 29.5in deep x 28in high; note that open well must be large enough to accommodate wiring behind and mobility of unit(approx. 2 to 3 in around instrument)) is required. ii.The table must include a noise suppression module to house a single Sogevac SV40 BI vacuum pump on a slide-out pump shelf and be equipped with an oil drip pan, mounted shock absorbers, and 2 (two) exhaust fans fitted with external ducting collars. iii.A drawer bank with three full extension lab drawers and one pull-out wiring shelf must be housed below the table surface. iv.Adjustable support arms for a 24 quote mark LCD/Flat screen monitor and keyboard must also be mountable to the table. v.An industrial surge suppressor must also be mounted on the rear of the table so as not to interfere with the work surface area. vi.New equipment only is being requested. Any old or refurbished items will not be acceptable. b.Specifications for Waters Prep 15 SFC system with 2767 Sample Manager and 3100 Mass Detector (Benches will support this system): ***See table on Minimum Essential Characteristics document by clicking Additional documentation link under Additional info heading*** 3.Requirement: Mobile benches to support Agilent G6460A QQQ 1260 LC/MS System (see Attachment Drawing C for Diagram: a.Benches must be able to accommodate the following specifications: i.Instrument table with minimum dimensions of 96in wide by 34in deep by 37in high (maximum measurements can be no more than a total of 5 in larger across all dimensions) with a chemical resistant laminate work surface (min 96 in wide by 34 in deep; note that surface does not have to be one complete piece but must be no more than 2 (two) separate pieces making up the required surface area one of which must have minimum dimensions of 60 in wide by 37 in deep) and steel frame is required. ii.The table must include a noise suppression module to house a single Edward E2M28 vacuum pump on a slide-out pump shelf and be equipped with an oil drip pan, mounted shock absorbers, and 2 (two) exhaust fans fitted with external ducting collars. iii.A drawer bank with three full extension lab drawers and one pull-out wiring shelf must be housed below the table surface. iv.Adjustable support arms for a 24 quote mark LCD/Flat screen monitor and keyboard must also be mountable to the table. v.An industrial surge suppressor must also be mounted on the rear of the table so as not to interfere with the work surface area. vi.New equipment only is being requested. Any old or refurbished items will not be acceptable. b.Specifications for Agilent G6460A QQQ 1260 LC/MS System (Benches will support this system): ***See table on Minimum Essential Characteristics document by clicking Additional documentation link under Additional info heading*** 4.Requirement: Mobile benches to support Agilent 7890A QQQ GC/MS System with G4513A Autoinjector (see Attachment Drawing D for Diagram) a.Benches must be able to accommodate the following specifications: i.Instrument table with minimum dimensions of 72in wide by 34in deep by 37in high (maximum measurements can be no more than a total of 5 in larger across all dimensions) with a chemical resistant laminate work surface (min 72 in wide by 34 in deep) and steel frame is required. ii.The table must include a noise suppression module to house a single vacuum pump (equivalent to a Edward E2M28 ) on a slide-out pump shelf and be equipped with an oil drip pan, mounted shock absorbers, and 2 (two) exhaust fans fitted with external ducting collars. iii.A drawer bank with three full extension lab drawers and one pull-out wiring shelf must be housed below the table surface. iv.Adjustable support arms for a 24 quote mark LCD/Flat screen monitor and keyboard must also be mountable to the table. v.An industrial surge suppressor must also be mounted on the rear of the table so as not to interfere with the work surface area. vi.New equipment only is being requested. Any old or refurbished items will not be acceptable. b.Specifications for Agilent 7890A QQQ GC/MS System with G4513A Autoinjector (Benches will support this system): ***See table on Minimum Essential Characteristics document by clicking Additional documentation link under Additional info heading*** 5.Requirement: Mobile Workstation Desk (See Attachment Drawing E for Diagram) a.Workstations must be able to accommodate the following specifications: i.Workstation lab desk which is a minimum of 48in wide by 34in deep by 30in high (maximum measurements can be no more than a total of 5 in larger across all dimensions) is needed for data analysis separate from the instrumentation in the same room. ii.Table surface must be black high pressure laminate a minimum of 48 in wide by 34 in deep. iii.Three drawers and a pencil drawer are required for storage. iv.Desk must be on locking casters to allow the desk to be repositioned easily. v.New equipment only is being requested. Any old or refurbished items will not be acceptable.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/W81XWH15T0131/listing.html)
 
Place of Performance
Address: US Army Medical Research Acquisition Activity ATTN: MCMR-AAA, 820 Chandler Street Frederick MD
Zip Code: 21702-5014
 
Record
SN03709481-W 20150425/150423235606-3315afe116bd5213c61c22590063c474 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.