Description
Question and Answer From Todays Site Visit On 04/239/2015: Question: Are there dedicated connections between the server and the current security system? Answer: No, the requirement is for that very purpose to connect the existing PACS and CCTV systems into the existing VA security system in accordance with the statement of work. Question: Are alternative methods other than hardwiring the existing PACS and CCTV systems to the VA security system allowed? Answer: No Question: Do pull boxes need to be labled? Answer: Yes, the Contracting Officer Representative (COR) will supply what the appropriate naming convention will be for the boxes. Question: Is the VA security system that is in place a stand-alone system? Answer: Yes Question: Where should the connection be made to patch the existing PACS and CCTV systems to the VA security system? Answer: Building 100, Room IF112, there exists an eight port switch with three ports available. Attached to this amendment is the wiring as-built for the main server room and 1F112 F-section of building 100. There was discussion during the site visit whether an update would need to occur to the Appendix A to show the panel location. It is already marked on the current drawing, just inside the main hallway, second room from the top on the right side. It's marked with SCP for security control panel and MUX for video fiber multiplexer.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BPVAMC/VAMCCO80220/VA24815Q1166/listing.html)
 
Document(s)
Attachment
 
File Name: VA248-15-Q-1166 VA248-15-Q-1166_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2016414&FileName=VA248-15-Q-1166-006.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2016414&FileName=VA248-15-Q-1166-006.docx

 
File Name: VA248-15-Q-1166 Main server room and 1F112 - wiring as-built.pdf (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2016415&FileName=VA248-15-Q-1166-007.pdf)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2016415&FileName=VA248-15-Q-1166-007.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 10,000 Bay Pines Blvd;Bay Pines FL 33744
Zip Code: 33744
 
Record
SN03714091-W 20150501/150429234924-3beea8638621c65adaffc08e80ecec7c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.