SOURCES SOUGHT
58 -- Market Survey for Services for the Joint Surveillance Target Attack Radar System (Joint STARS) Surveillance and Control Data Link
- Notice Date
- 4/29/2015
- Notice Type
- Sources Sought
- Contracting Office
- ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
- ZIP Code
- 21005-1846
- Solicitation Number
- MARKET-SURVEY-5829-1
- Response Due
- 5/8/2015
- Archive Date
- 6/28/2015
- Point of Contact
- Lindsay Newhouse, 4438615484
- E-Mail Address
-
ACC-APG - Aberdeen Division B
(lindsay.d.newhouse.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- DO NOT CONTACT POSTER - L. NEWHOUSE. FOR ANY INFORMATION CONTACT: Raymond Lo, Electronics Engineer, (443) 861-3052 The Government is seeking one source to provide the services required to support the Joint Surveillance Target Attack Radar System (Joint STARS) Surveillance and Control Data Link (SCDL) Ground Data Terminal (GDT) for a period of five years. The Government will order services on a Firm-Fixed-Price (FFP) and/or Cost Plus Fixed Fee (CPFF) basis. The current source for GDT supplies and services is Cubic Defense Applications (CDA), CAGE code 94987. The Government does not possess and does not intend to procure from CDA the technical data package. Contractual requirements for this potential contract would include, but not be limited to: performing and reporting the results of inspections, tests, evaluations of parts and repairs; maintaining a detailed parts tracking system for repairs; providing expedited parts repairs; preparing and submitting engineering change proposals, requests for variance, specification change notices, and value engineering change proposals; complying with the Government's requirements for item unique identification and marking requirements; providing updates to technical manuals and training course materials, as required; maintaining and providing technical-engineering and logistics data used to support the GDT; identifying parts with Diminishing Manufacturing Sources and Material Shortages (DMSMS) - End of Life (EOL) problems, investigating alternatives, recommending solutions, and potentially finding replacement parts; complying with preservation, packaging, and marking parts for shipment; complying with radio frequency identification requirements; providing assistance with the resolution of, and resolving obsolescence, maintenance, and technical issues; providing a Field Service Representative (FSR) for site visits; providing 24 hours-7 days-per-week on-call support services via telephone, emails, and written documents; providing FSRs that are mobile and able to deploy to both CONUS and OCONUS locations, including hostile and hazardous areas, within seven days; complying with personnel, program, company, and facility security requirements for handling, generating, and transporting classified information-material up to and including SECRET; complying with contract manpower reporting requirements to report all Contractor manpower required for performance of the contract; and maintaining a cost reporting system and submitting reports to the Government. The source will need to be able to provide repair, and/or verify the proper operation of the following parts, the list of which should not be considered all-inclusive (NSN, Nomenclature, and part number [PN] are provided; the CAGE Code applicable to all parts is 94987): NSN 6145-01-372-5435,CA ASSY,AC PWR,LCU TO JSIU,PN 232796-1; NSN 6145-01-372-5434,CA ASSY,DATA/CONT,GDT, PN 232797-1; NSN 6145-01-372-5436,CA ASSY,PWR LCU-AC/AC CONVERTER, PN 232798-1; NSN 4140-01-418-6304,FAN, VANEAXIAL, PN 233040-2; NSN 5955-01-406-3073,OSCILLATOR,CRYSTAL,PN 233820-2; NSN 5985-01-375-3518,VERT REF ASSY, PN 265340-1 & 261330-1; NSN 5820-01-385-8516,CONTROL,ANTENNA (LCU), PN 261510-2; NSN 5995-01-407-2194,CABLE ASSY,LCU-MASTHD,GDT, PN 261556-1; NSN 5915-01-374-4271,FLTR ASSY,EMI/EMP,SHELTER, PN 261564-1; NSN 5895-01-374-4295,CONT-INTFC UNIT ASSY, PN 261900-3; NSN 5985-01-374-0760,PEDESTAL ASSY,ANTENNA, PN 261950-1; NSN 5895-01-406-6804,INTERFACE ASSY,EMI/EMP,PN 265029-2; NSN 5998-01-374-4274,UPCONV ASSY,ENCL,CTR SECT,PN 265165-1 & 265165-3; NSN 5998-01-472-5550,SYNTHESIZER ASSY,PN 265230-2; NSN 5895-01-374-4294,CONVERTER,FREQ,STATIC, PN 265400-1; NSN 8145-01-472-4861,CNTNR ASSY,SHPNG,ANT,PN 270836-1; NSN 5985-01-433-0895,ANT ASSY,GND DATA TERM,PN 270840-2: NSN 5985-01-496-2702,FXTR ASSY,HANDLING ANT,PN 261407-1 & 270845-1; NSN 5985-01-406-4921,RADOME, MASTERHEAD,UPPER,PN 270901-1; NSN 5999-01-519-9353,BALLISTIC SHLD ASSY,ANT,PN 270914-1; NSN 5995-01-407-4274,CA ASSY,LANDLINE,SHELTER,PN 270917-1; NSN 5995-01-408-7704,CA ASSY,LANDLINE,SHELTER,PN 270917-2; NSN 5995-01-407-4275,CA ASSY,MASTHD,LANDLINE,PN 270918-1; NSN 5995-01-407-2193,CA ASSY,MASTHD,LANDLINE,PN 270918-2; NSN 5998-01-472-5534,FREQ MODULATOR ASSY,PN 283900-1; NSN 8145-01-440-7775,CONTAINER,STOWAGE,ANTENNA,PN 305900-1; NSN 5998-01-374-1305 & 5998-01-472-6636,CCA,LCU MASTER COUNTER,PN 261650-1 & 306000-1; NSN 5998-01-374-1304 & 5998-01-472-6635,CCA,LCU FAST TIMING,PN 261630-1 & 306010-1; NSN 5998-01-374-1303 & 5998-01-472-4866,CCA,TIMING ADJUST,PN 261680-1 & 306020-1; NSN 5998-01-374-0170 & 5998-01-472-5535,CCA,UPLINK DATA NETWORK,PN 261720-1& 306050-1; NSN 5998-01-374-1306 & 5998-01-472-8359,CCA,CODE GENERATOR,PN 261670-1 & 306060-1; NSN 5998-01-374-0166 & 5998-01-472-8357,CCA,THRESHOLD INTEGRATOR, PN 261575-1 & 306070-1; NSN 5998-01-472-4868,CCA,RANDOM INTERLEAVER,PN 306080-1; NSN 5998-01-374-0168,CCA,ANALOG CORRELATOR,PN 261690-1 & 306090-1; NSN 5998-01-374-0167 & 5998-01-472-4865CCA,VITERBI DECODER,PN 261580-1 & 306100-1; NSN 5998-01-472-5547,CCA,XCVR/LCU BIT,PN 306110-1; NSN 5998-01-472-6630,CCA,FREQ SEL/RCG,PN 306120-1; NSN 5998-01-472-8352,CCA,CONTROLLER I/O,PN 306130-1; NSN 5998-01-374-0169 & 5998-01-472-8354,CCA,MASTHEAD I/O,PN 261710-1 & 306140-1; NSN 5998-01-472-5553,CCA,RED/BLK ISOLATOR,PN 306160-1; NSN 5998-01-472-5552,CCA,CRYPTO INTERFACE,PN 306180-1; NSN 5998-01-472-5548,CCA,1553 I/O,PN 306220-1; NSN 5998-01-374-0173,CCA,LCU CABLE I/O,PN 265360-1 & 306230-1; NSN 5998-01-374-0176,CCA,MASTHEAD BIT/NED,PN 265390-1 & 306240-1; NSN 5998-01-374-0174 & 5998-01-472-8355,CCA,ANTENNA CONTROL PN 261195-1 & 306250-1; NSN 5998-01-472-4860CCA,DCO/RANGE TONE GEN,PN 306260-1: NSN 5998-01-374-0175 & 5998-01-472-8351,CCA,VERT REF AVERAGER, PN 265380-1 & 306270-1; NSN 5998-01-374-0747 & 5998-01-555-6406,CCA,SEQUENCE CONTROLLER, PN 265640-3 & 306590-1; NSN 5998-01-472-6643,DUPLEXER ASSY,PN 306660-2; NSN 5998-01-374-0162 & 5998-01-472-4867,MSTR CLK OSC ASSY,ANT CNT, PN 261700-1 & 306620-1; NSN 5963-01-374-8565 & 5963-01-472-8362,DOWNLINK RCVR ASSY,ANT, PN 261530-1 & 306640-1; NSN 5998-01-374-0159 & 5998-01-472-4862,FM DEMODULATOR,PN 261550-1 & 306700-1; NSN 5998-01-472-6627,DOWNCONVERTER/2ND L.O.,PN 306600-1; NSN 5998-01-472-5549,CCA,SEQ CONT MEMORY,PN 306040-1; NSN 5998-01-472-5545,CCA,PROCESSOR INTERFACE,PN 306190-1; NSN 5998-01-472-5551,CCA,CRYPTO CONTROLLER,PN 306170-1; NSN 5998-01-472-5554,CCA,MODEM INTERFACE,PN 306150-1; NSN 5998-01-479-0480,CCA, I/O CPU,PN 306200-1; NSN 5955-01-472-4854,REF OSC ASSY,REC/TRANS,PN 306740-1; NSN 5998-01-472-5539CCA, I/O CPU MEMORY,PN 306210-1; NSN 5985-01-406-5829,TRIPOD, ANTENNA,PN 265490-1 Each potential source must provide a response to this sources sought solicitation, addressing their ability to provide the services specified above for the GDT. The response is not to exceed 10 pages in length. Acceptable file formats for the response include Microsoft Word, text, rich text, or Adobe Acrobat. Email the response to raymond.c.lo.civ@mail.mil by close of business on 08 May 2015. No phone inquiries will be accepted, either as a response to this action or for information requests. All requests for information must be emailed to the above address. This market survey is not to be construed as a guarantee that the Government will issue a future solicitation for the services cited herein.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/a2e5e9b5ef40c7b04832bd0cef2a66a0)
- Place of Performance
- Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
- Zip Code: 21005-1846
- Zip Code: 21005-1846
- Record
- SN03715135-W 20150501/150429235922-a2e5e9b5ef40c7b04832bd0cef2a66a0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |