SOURCES SOUGHT

Z -- Design-Build repair of the Los Alamitos building 912 Fire Suppression System - W91238-15-S-1849 Sources Sought Notice

Notice Date
5/1/2015
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Sacramento, 1325 J. Street, Sacramento, California, 95814, United States
 
ZIP Code
95814
 
Solicitation Number
W91238-15-S-1849
 
Point of Contact
Daniel E. Czech, Phone: 9165577012
 
E-Mail Address
Daniel.E.Czech@usace.army.mil
(Daniel.E.Czech@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
W91238-15-S-1849 Sources Sought Notice W91238-15-S-1849 This is a SOURCES SOUGHT NOTICE for Market Research ONLY to determine the availability of small business firms for a potential small business category type set-aside. NO AWARD will be made from this Sources Sought. NO SOLICITATION, SPECIFICATIONS, OR DRAWINGS ARE AVAILABLE AT THIS TIME; therefore, do NOT request a copy of a solicitation. Potential offerors having the skill, capabilities and bonding necessary to perform the described project are invited to provide feedback via email to DANIEL CZECH at Daniel.E.Czech@usace.army.mil. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Particularly, the purpose of this NOTICE is to gain knowledge of potential small business sources to include small business in the following categories: Small Business, Certified 8(a), Certified HUB Zone, and Service-Disabled Veteran-Owned Small Business (SDVOSB), for a Design-Build repair of the Los Alamitos building 912 Fire Suppression System. The capabilities will be evaluated solely for the purpose of determining to Set-Aside for the Small Business Community or to conduct as an Other Than Small Business Procurement. Other than small businesses may respond to this NOTICE in the event the market does not indicate SB interest, however, preference will be given to the SB categories listed above. The government must ensure there is adequate competition among the potential pool of available contractors. This project is planned for advertising on/about July 22, 2015. In accordance with FAR 36.204, the estimated value of the resulting contract is expected to be between $1M and $5M. The resulting contract type is expected to be a Firm-Fixed Price. The NAICS Code is 238220, the size standard is $15.0 million, and the Federal Supply Code is Z2JZ, Repair or Alteration of Miscellaneous Buildings. Under Federal Acquisition Regulation (FAR) guidelines 52.219-14, any 8(a) concern will perform at least 25% of the cost of the contract, not including the cost of materials, with its own employees for specialty trades (238XXX). Under FAR 52.236-1, any other-than-small business concern shall perform on the site, and with its own organization, work equivalent to at least 25 percent of the total amount of work to be performed under the contract. PROJECT DESCRIPTION This project involves the fire suppression retrofit of the hangar bays of Building 912 located on the Joint Forces Training Base in Los Alamitos, CA. The Group I aircraft hangar bays (approx. 50,000 sf total) house both fixed-wing and rotary-wing aircraft. The existing fire suppression system to be removed utilizes aqueous film forming foam (AFFF) distributed through an overhead pre-action closed head sprinkler system, 6 floor-mounted oscillating monitors and 2 manual hose reels stations. Features to be removed include; 1 AFFF concentrate tank, 2 concentrate pumps, 4 pre-action risers, overhead sprinkler system, all oscillating monitors and hose reel stations, all associated fire suppression piping and fire alarm / flame detection systems. The new system to be installed within the hangar bays shall be a combination of automatic wet-pipe sprinkler protection and an automatic low-level high-expansion foam system. The system shall be compliant with current DoD Unified Facilities Criteria (UFC) and National Fire Protection Association (NFPA) requirements including but not limited to UFC 3-600-01, UFC 4-211-01, NFPA 13, NFPA 409, NFPA 11, NFPA 20 and NFPA 22. The project will also involve the installation of two above-ground water storage tanks (approx. 135,000 gal. each), a co-located fire pump house, an electric- or diesel-engine driven fire pump (approx. 4,000 gpm, 130 psi.), modifications to the existing fire water distribution system beneath hangar floor, upgrades to the existing electrical distribution system, and installation of criteria complaint fire alarm system. CAPABILITY STATEMENT The following requests are designed to apprise the US Army Corps of Engineers, Sacramento District, of any prospective construction contractors' project execution capabilities. Please provide your response to the following. The submission is limited to 10 pages. 1) Offeror's name, DUNS#, address, point of contact, phone number, and e-mail address. 2) Offeror's interest in bidding on the solicitation when it is issued. 3) Offeror's capability to perform a design-build contract of this magnitude and complexity and comparable work performed within the past 3 years - Describe your self-performed effort, brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) - provide at least 3 examples. 4) Offeror's socioeconomic type and Business Size (Small Business, HUBZone, Service Disabled Veteran Owned and/or Small Business, 8(a), WOSB, etc.). 5) Offeror's Joint Venture information if applicable - existing and potential. 6) Offeror's Bonding Capability in the form of a letter from Surety. The Capabilities Statement for this sources sought is not expected to be a Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather short statements regarding the company's ability to demonstrate existing-or-developed expertise and experience in relation to the areas specified herein. Any commercial brochures or currently existing marketing material may also be submitted with the Capabilities statement. Please ensure that all information is submitted as one (1) document. Submission of Capabilities statement is not a prerequisite to any potential future offerings, but participation will assist the Corps of Engineers in tailoring requirements to be consistent with industry capabilities. This synopsis is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. Respondents will not be notified of the results of the evaluation. After completing its analysis, the Government will determine whether to limit competition among 8(a), Service Disabled Veteran, HubZone, or all Small Business firms or proceed with full and open competition as Other Than Small Business. Offers that do not meet all requirements or submit within the allotted time will not be considered. Please notify this office in writing by email by 1:00 PM Pacific Time on May 19, 2015. Submit response and information through email to: Daniel.E.Czech@usace.army.milPlease include the Sources Sought No. W91238-15-S-6045 in the subject line.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W91238-15-S-1849/listing.html)
 
Place of Performance
Address: Joint Forces Training Base, Los Alamitos, California, United States
 
Record
SN03717627-W 20150503/150501234919-beecc3b3984e6ce7cd0267621fb087cb (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.