DOCUMENT
J -- PM-TISSUE PROCESSOR - Attachment
- Notice Date
- 5/8/2015
- Notice Type
- Attachment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
- ZIP Code
- 37129
- Solicitation Number
- VA24915N0488
- Response Due
- 5/14/2015
- Archive Date
- 7/13/2015
- Point of Contact
- Carlos Suggs
- Small Business Set-Aside
- Total Small Business
- Description
- This is a sources sought notice only; it is not a request for quotations or offers. This sources sought notification is for the Department of Veterans Affairs Network Contracting Office 9 for the Robley Rex Veteran Medical Centers (VAMC) located at 800 Zorn Avenue, Louisville, Kentucky to determine the availability of Small Business (preferably Service-Disabled Veteran-Owned and/or Veteran-Owned) Entities within the area, relative to NAICS code 811219, with a size standard of $20.5M, and possessing the skills and capabilities necessary to provide preventive maintenance services for the Leica ASP 6025 Tissue Processor System located at the VAMC Louisville per the Statement of Work (SOW). The contract period shall be for a single visit to perform the requirements of the Statement of Work (SOW) scheduled to begin on/about June 1, 2015. Any additional visits to complete the service must be preauthorized by the Contracting Officer. The contractor shall furnish all necessary labor, transportation, parts and expertise to provide preventive maintenance on the Lecia ASP 6025 system. To be considered eligible for consideration, contractor must provide a field service representative that has been trained by the Original Equipment Manufacturer (OEM) on the specific model of equipment he/she is being asked to provide services for. Any and all third parties must be authorized and certified by the OEM to provide the services. The contractor must have access to all service passwords needed to complete the preventive maintenance. Contractor must provide, upon request, documentation of factory certified service/maintenance training on the specific equipment under the terms of this contract. The Contracting Officer and/or Contracting Officer Representative (COR) specifically reserves the right to reject any of the Contractor's personnel and refuse them permission to work on the equipment outlined in Attachment 1, based upon credentials provided. Subcontracting of any ensuing award will not be allowed without written permission from the Contracting Officer. Service response on calls from unauthorized personnel will result in non-payment. 1. SERVICES TO BE PROVIDED: A.General: 1)Contractor will provide the necessary manpower, supervision, tools, and parts to properly execute the preventive maintenance of the equipment listed in Attachment 1. All containers, including toolkits, can be subject to search at any time. 2)A "Field Service Report" (FSR) must be generated and a copy given to the Robley Rex VAMC's Contracting Officer's Representative (COR) or designee after the PM is performed. B.Preventive Maintenance (PM): 1)Preventive Maintenance will be performed by the contractor based upon preventative maintenance guidelines set forth by the manufacturer. 2)Contractor will furnish any required parts/services needed to perform Preventive Maintenance. 3)PM's shall consist of all parts/services, electrical or mechanical, necessary to maintain the equipment in good operating order, based upon Manufacturer's service documentation recommended procedures and frequencies. C.Documentation: A documentation package acceptable for Joint Commission purposes will be maintained by the contractor and made available to the Robley Rex VA Medical Center. Required features include, at a minimum: 1)Serial Number of equipment serviced 2)Any and all work performed on a particular date 2.SPECIAL INSTRUCTIONS: A.Contractor Check-In: Upon arrival, the contractor will check-in with the authorized VCS attendant to receive an identification sticker, prior to performing service(s) at the Robley Rex VA Medical Center. The contractor shall wear visible identification at all times while on the premises of the Robley Rex VA Medical Center, displaying name and company ID. The contractor is also required to stop by Biomedical Engineering Room B-029 before and after work is completed. B.Documentation: At the conclusion of the scheduled maintenance visit, the contractor will provide a written service report indicating the date of service, the model, serial number, and location of equipment serviced; the name of the representative, and the services performed and parts replaced. The reports will be delivered to the Biomedical Engineering Shop, Room B-029. An electronic copy may be emailed to the Biomedical Engineering Point of Contact. ? Attachment 1: EQUIPMENT LIST 1.EE# 67723, Tissue Processor, Serial Number: 0270, Model: ASP6025, Located in room A348A-1 2.EE# 67295, Tissue Processor, Serial Number: 0264, Model: ASP6025, Located in room A348A-1
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/VA24915N0488/listing.html)
- Document(s)
- Attachment
- File Name: VA249-15-N-0488 VA249-15-N-0488.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2036534&FileName=VA249-15-N-0488-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2036534&FileName=VA249-15-N-0488-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA249-15-N-0488 VA249-15-N-0488.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2036534&FileName=VA249-15-N-0488-000.docx)
- Record
- SN03724991-W 20150510/150508234655-f006125800574b23110b0f031e2f031d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |