Description
The VA San Diego Healthcare System (VASDHS) at 3350 La Jolla Village Drive, San Diego, California 92161, is contemplating a Request for Quote (RFQ) solicitation for a dual pump hemodialysis reverse osmosis water system. The contemplated solicitation shall be for a fixed price, single award purchase order. The water system shall be FDA 501k cleared for use in hemodialysis, designed for use with cold (non-tempered) pre-treatment water, fully redundant and able to produce water in the event of a pump failure. Also, it must include a graphical user interface, include a remote monitor with software for system monitoring via the local area network (LAN), and be a double-pass reverse osmosis (RO) system that is capable of providing ultrapure, or near ultrapure water, without the aid of UF, UV, or endotoxin filters. The equipment must be a direct feed design, and not employ the use of a water tank. Each tap from the distribution system must employ a dual-hose, crush-proof tubing design that provides a constant flow of water through the tubing. The entire system must provide an in-line heat disinfection method. The heating system shall be programmable and have the capability of disinfecting the RO, distribution lines, and connected dialysis machines for complete end-to-end disinfection. The design of the entire system shall incorporate the use of pharmaceutical quality, orbitally welded 316L stainless steel or flexible, insulated high-grade PEX tubing. Flexible tubing shall be used for all connections inside walls and cabinets to aid in installation. Also, the system shall include an automatic, self-cleaning system that continuously cleans the RO membranes without the aid of corrosive chemicals, thus preventing contamination with bacteria. The system shall be designed to recover at least 85% of the feed water consumed into product water, the system shall monitor for system leakage and notify hemodialysis staff when it occurs, the system shall be capable of shutting itself down if a leak is detected, and the system shall allow for a signal from an external hard water monitor. Installation of the system is part of the contemplated solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/VA26215Q0224/listing.html)
 
Document(s)
Attachment
 
File Name: VA262-15-Q-0224 VA262-15-Q-0224_3.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2050830&FileName=VA262-15-Q-0224-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2050830&FileName=VA262-15-Q-0224-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA San Diego Healthcare System;3350 La Jolla Village Drive;San Diego, CA
Zip Code: 92161
 
Record
SN03732448-W 20150517/150515234532-7875d07b709dd02fc39f8cf59a0a620b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.