Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 23, 2015 FBO #4928
MODIFICATION

99 -- Water System

Notice Date
5/21/2015
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
ACC-APG-TENANT CONTRACTING DIV,, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
 
ZIP Code
21005-3013
 
Solicitation Number
W91ZLK-15-T-0187
 
Response Due
5/26/2015
 
Archive Date
7/20/2015
 
Point of Contact
MARY L. CHEEK, 443-861-4730
 
E-Mail Address
ACC-APG-TENANT CONTRACTING DIV
(mary.l.cheek6.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
***CORRECTIONS MADE TO POSTING DUE TO ADMINISTRATIVE ERROR*** W91ZLK-15-T-0187 THIS IS A SOURCES SOUGHT NOTICE REPRESENTING MARKET RESEARCH ONLY. THIS IS NOT A REQUEST FOR QUOTATIONS, INVITATION FOR BIDS, OR REQUEST FOR PROPOSALS. NO CONTRACT AWARD WILL RESULT FROM THIS SOURCES SOUGHT NOTICE. The Army Contracting Command at Aberdeen Proving Ground is conducting market research to determine the availability of small businesses, capable of fulfilling the Aberdeen Test Center (ATC) need for High capacity water system needed to feed 4 large (32 to 64 cu ft) environmental chambers and two CI5000 weatherometers and small test equipment. Systems shall produce Type 2 purified water with a 1400 liters/day capacity and a 350 liter reservoir. Water used for testing all types of Army materiel and must be Type II so as not to interfere/contaminate test items. Large volume chambers will be able to run simultaneously, enabling lab personnel to increase testing. SPECIFICATIONS: This entire system must have interchangeable OEM Millipore parts in order for lab personnel to limit the number of stock items and be able to interchange the filters with an existing Elix (2) 35 water system setup. a. Water purification system must supply Type 2 purified water. b. Be able to produce 1400 liters/day of Type 2 water. c. Include a 5 GPM distribution pump at 40 PSI (example:MQ3-35B Grundfos or equal is used in lab) d. Tap water pretreatment automatic backwashing filters (one multimedia and one carbon filter) e. Final water pretreatment with OEM (original equipment manufacturer) EMD Millipore progard -L and Prepak-L pretreatment packs with mounting bracket. Able to produce 35 liters per hour, max 700 liters per day (at 25 C /30% recovery), Product Quality to storage tank: greater than 5 m -cm ( typically 10-15 m -cm) less than 30 ppb TOC, less than 10 cfu/ml bacteria, 99.9 % silica rejection. f. 350 liter storage tank with stand, over flow sensor, vent filter. The applicable North American Industry Classification System (NAICS) code for this acquisition is 334516- Analytical Laboratory Instrument Manufacturing. The small business size standard is 500 employees. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: The contractor must include in their Capability Statement (1) the company name, address, phone number/email address for POC at the company, certification of business size, cage code and DUNS number, (2) staff expertise and experience along with their availability to perform work on this specific piece of equipment. DISCLAIMER AND IMPORTANT NOTES: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in responses. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or to provide feedback to respondents with respect to any information submitted. Vendors capable of furnishing the Government with the supplies specified in this Sources Sought notice should submit their Capability Statement to the email address below. Capability Statements are due by May 26, 2015 at 3:00 PM Eastern Standard Time (EST). Capability Statements must be submitted via email only to Ms. Mary.L.Cheek6.civ@mail.mil with a copy furnished to Mrs. LaKia.L.Johnson.civ@mail.mil. Please reference W91ZLK-15-T-0187 in the subject line of the email to ensure proper routing. Faxed or postal mailed copies will not be accepted.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/58800606670e376e6d83aa72f4d90835)
 
Place of Performance
Address: ACC-APG-TENANT CONTRACTING DIV, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
Zip Code: 21005-3013
 
Record
SN03740165-W 20150523/150522000347-58800606670e376e6d83aa72f4d90835 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.