MODIFICATION
43 -- Chiller Compressors - Solicitation
- Notice Date
- 5/27/2015
- Notice Type
- Modification/Amendment
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- Department of the Navy, United States Marine Corps, MCB Camp Pendleton - RCO, PO Box 1609, Oceanside, California, 92051-1609, United States
- ZIP Code
- 92051-1609
- Solicitation Number
- M00681-15-T-0108
- Archive Date
- 6/17/2015
- Point of Contact
- Tiffany Nelson, Phone: (760) 725-8142, Christopher Lopez, Phone: 760-725-8128
- E-Mail Address
-
tiffany.nelson@usmc.mil, christopher.lopez2@usmc.mil
(tiffany.nelson@usmc.mil, christopher.lopez2@usmc.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Sustainable Acquisition RFQ Cover Sheet BRAND NAME DETERMINATION AND FINDINGS 1449 (Solicitation) NOTE: THIS IS A BRAND NAME REQUIREMENT. VENDORS SUBMITTING QUOTES FOR SUBSTITUTE OR "ALTERNATIVE" ITEMS WILL NOT BE CONSIDERED FOR ANY RESULTING AWARD FOR THIS SOLICITATION. ATTENTION! This solicitation is for the following: Copeland ZR190KCE-TE5-465 compressors PART NUMBER: 2400-3835 Qty: 2 The Requirements: •· Copeland ZR190KCE-TE5-465 compressors that will compress refrigerant vapor to a higher pressure so that the condensing pressure of the refrigerant is at a higher temperature than the ambient air used to condense it. •· Must be a hermetic, scroll compressor provided with external overload protection, crankcase heaters, service valves for service isolation and in-line fuse protection. •· Compressors must have a 19 HP motor, two independent 15 ton rated refrigerant capacity circuits, and 208/230/60/3 voltage specs. •· Compressors must have specific physical characteristics to be able to be installed into a higher assembly (Chiller PACVPV0300D3) such as footprint, inlet and discharge pipe size connections, HP rating, capacity and refrigerant usage rating. •· Compressor needs an exterior and interior copper plated steel 1.25-12 thread rotalock spud discharge check valve torque range 240-360 in-lb. It has to be located 20.45 inches above the base of the cylinder body to the top. •· Compressor needs an exterior and interior copper plated steel 1.75-12 thread rotalock spud suction fitting torque range 360-480 in-lb. It has to be located 5.53 inches above the base of the cylinder body and be offset 30 degrees to the left of the previously stated check valve. •· Compressor needs an oil sight glass to be able to perform preventative maintenance and troubleshoot. It has to be located 3.64 inches above the base of the cylinder body and be 30 degrees to the right of the spud discharge check valve. This location is critical to ensure visibility of sight glass while installed in the chiller. •· The base must be 9.55 inches by 9.55 inches with bolt holes in the corners 7.5 inches apart.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/USMC/M00681/M00681-15-T-0108/listing.html)
- Place of Performance
- Address: Marine Corps Air Station Yuma, AZ, Yuma, Arizona, 85369, United States
- Zip Code: 85369
- Zip Code: 85369
- Record
- SN03743119-W 20150529/150527235108-a3bd1f57c75c35b6a37367a70e3c1e8c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |