Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 29, 2015 FBO #4934
MODIFICATION

43 -- Chiller Compressors - Solicitation

Notice Date
5/27/2015
 
Notice Type
Modification/Amendment
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Navy, United States Marine Corps, MCB Camp Pendleton - RCO, PO Box 1609, Oceanside, California, 92051-1609, United States
 
ZIP Code
92051-1609
 
Solicitation Number
M00681-15-T-0108
 
Archive Date
6/17/2015
 
Point of Contact
Tiffany Nelson, Phone: (760) 725-8142, Christopher Lopez, Phone: 760-725-8128
 
E-Mail Address
tiffany.nelson@usmc.mil, christopher.lopez2@usmc.mil
(tiffany.nelson@usmc.mil, christopher.lopez2@usmc.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Sustainable Acquisition RFQ Cover Sheet BRAND NAME DETERMINATION AND FINDINGS 1449 (Solicitation) NOTE: THIS IS A BRAND NAME REQUIREMENT. VENDORS SUBMITTING QUOTES FOR SUBSTITUTE OR "ALTERNATIVE" ITEMS WILL NOT BE CONSIDERED FOR ANY RESULTING AWARD FOR THIS SOLICITATION. ATTENTION! This solicitation is for the following: Copeland ZR190KCE-TE5-465 compressors PART NUMBER: 2400-3835 Qty: 2 The Requirements: •· Copeland ZR190KCE-TE5-465 compressors that will compress refrigerant vapor to a higher pressure so that the condensing pressure of the refrigerant is at a higher temperature than the ambient air used to condense it. •· Must be a hermetic, scroll compressor provided with external overload protection, crankcase heaters, service valves for service isolation and in-line fuse protection. •· Compressors must have a 19 HP motor, two independent 15 ton rated refrigerant capacity circuits, and 208/230/60/3 voltage specs. •· Compressors must have specific physical characteristics to be able to be installed into a higher assembly (Chiller PACVPV0300D3) such as footprint, inlet and discharge pipe size connections, HP rating, capacity and refrigerant usage rating. •· Compressor needs an exterior and interior copper plated steel 1.25-12 thread rotalock spud discharge check valve torque range 240-360 in-lb. It has to be located 20.45 inches above the base of the cylinder body to the top. •· Compressor needs an exterior and interior copper plated steel 1.75-12 thread rotalock spud suction fitting torque range 360-480 in-lb. It has to be located 5.53 inches above the base of the cylinder body and be offset 30 degrees to the left of the previously stated check valve. •· Compressor needs an oil sight glass to be able to perform preventative maintenance and troubleshoot. It has to be located 3.64 inches above the base of the cylinder body and be 30 degrees to the right of the spud discharge check valve. This location is critical to ensure visibility of sight glass while installed in the chiller. •· The base must be 9.55 inches by 9.55 inches with bolt holes in the corners 7.5 inches apart.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/USMC/M00681/M00681-15-T-0108/listing.html)
 
Place of Performance
Address: Marine Corps Air Station Yuma, AZ, Yuma, Arizona, 85369, United States
Zip Code: 85369
 
Record
SN03743119-W 20150529/150527235108-a3bd1f57c75c35b6a37367a70e3c1e8c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.