DOCUMENT
65 -- BLADDER SCAN, BVI 9400 - Attachment
- Notice Date
- 6/16/2015
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VA Sierra Pacific Network (VISN 21);VA Central California Health Care System;2615 E. Clinton Ave;Fresno CA 93703-2223
- ZIP Code
- 93703-2223
- Solicitation Number
- VA26115Q0744
- Response Due
- 6/16/2015
- Archive Date
- 7/16/2015
- Point of Contact
- LAVERN MARSHALL
- Small Business Set-Aside
- N/A
- Description
- Table of Contents PRICE/COST SCHEDULE2 Item Information2 DELIVERY SCHEDULE2 INSTRUCTIONS TO OFFERORS2 SALIENT CHARACTERISTIC4 This document is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation, proposals are being requested, and a written solicitation will not be issued. The proposed contract action is for supplies or services for which the Government intends to solicit Resonance Technology, Inc. Interested persons may submit offers, and all eligible offers received prior to June 19, 2015 at 5:00 PM PST will be considered by the Government. The NAICS code is 339112 and the size standard is 500 Employees. This is an open market competitive with a small business set aside acquisition. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-82 effective, May 07, 2015. The list of contract line item number(s) and items, quantities and units of measure, (including option(s), if applicable). PRICE/COST SCHEDULE Item Information ITEM NUMBERDESCRIPTION OF SUPPLIES/SERVICESQUANTITYUNITUNIT PRICEAMOUNT 0270-0404BLADDER SCANNER BVI 94002.00EA____________________________ 0800-0322BVI 9400 ROLLING CART2.00EA_______________________ SERVICE MANUALS & REFERENCE MATERIALS1.00EA ___________ ____________ GRAND TOTAL_____________ DELIVERY SCHEDULE ITEM NUMBERQUANTITYDELIVERY DATE 1-3VA Northern CA Health Care System 10535 Hospital Way Mather, CA 95655-4200ALL30 DAYS ARO INSTRUCTIONS TO OFFERORS Only electronic offer will be accepted. Offers are due by 5:00 PM PDT June 19, 2015. FAR 52.212-2 EVALUATION--COMMERCIAL ITEMS (JAN 1999) (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factor shall be used to evaluate offers: The Government will award to the lowest price, technically acceptable offeror. Brand name only. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). (c) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Provision) ADDITIONAL SOLICITATION PROVISIONS/CONTRACT CLAUSES: FAR 52.252-2 Clauses Incorporated by Reference (Feb 1998) For the purpose of this clause, the fill-ins are http://www.acquisition.gov/far/index.html (FAR) and http://www1.va.gov/oamm/oa/ars/policyreg/vaar/index.cfm (VAAR), respectively. FAR 52.212-4 Contract Terms and Conditions -- Commercial Items (FEB 2012). FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items (Sep 2013) For the purposes of this clause, items (b) 4, 12, 23, 26-29, 31, 38, 40ii, 42, and 48 are considered checked and apply. VAAR 819.7003Class Deviation from VAAR 819.7003, Eligibility VAAR 852.203-70 Commercial Advertising (Jan 2008) VAAR 852.232-72Electronic Submission of Payment Requests (November 2012) FAR 52.252-1Solicitation Provisions Incorporated by Reference (FEB 1998)http://www.acquisition.gov/far/index.html (FAR) and http://www.va.gov/oamm/oa/ars/policyreg/vaar/index.cfm (VAAR) FAR 52.212-1 Instructions to Offerors - Commercial Items (Jul 2013). FAR 52.212-3 Offeror Representations and Certifications -- Commercial Items (Aug 2011): Offerors must return this provision with their proposal. They may either (1)complete all relevant portions of the provision or (2) complete paragraph (b) of the provision and indicate that it has completed official representations and certifications online at https://orca.bpn.gov/login.aspx. ? SALIENT CHARACTERISTIC Brand Name or Equal 6/16/2015 Form, fit and function to VERATHON BLADDERSAN BVI 9400 1)Essential/significant physical, functional, or performance characteristics. a)Compatibility - Measures bladder volume noninvasively on a wide range of patients Assess urinary retention and postoperative urinary retention. Reduce rates of catheter-associated urinary tract infection Onboard video tutorial Precision aiming ability via console and probe Savings calculator tracks instrument usage, urinary catheterizations avoided and UTI costs saved Voice annotation for exams to ensure valuable patient/exam data is retained. Can wirelessly uploaded exams Calibrations and software upgrades may be performed online using ScanPoint Durable and reliable design Compact and easy to read console features Color LCD Display Brightness Control Onboard Computer Hand Held Probe Display:13.36 x 10.13 cm Transducer Diameter: 13mm (0.512 inches) Transducer Frequency 3.0 MHz and 1.74 MHz Transducer bandwidth 75% at 10 dB <3 seconds time from 3D scan initiation to result display Integrated Printer (Thermal Printer) Lithium-ion Battery Battery Charger/Wireless hub Operational and maintenance manual Install quick reference card. b)Dimensions - c)Weight- 5.2 lbs with battery d)Industry Standard - EN/IEC 60601-1 (1988 +a1 +A2); EN/IED 60601-1 (2005); EN/IEC60601-1-2 (EMC) EN/IEC 60601-2-37 (Diagnostic Ultrasound) e)Purpose - To provide a portable ultrasound instrument that provides a noninvasive measurement of urinary bladder volume. f)Governing Body or Organization -None Line ItemModelDescription (Specification)Qty 10270-0404Bladder Scanner BVI 94002 20800-0322BVI 9400 Rolling Cart2 3Service Manuals/Reference Materials1 Per VAAR 811.104 and 811.105, I certify the following regarding the above information: 1.The salient characteristics listed above are essential to the Government's requirements. 2.To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/FrVAMC570/FrVAMC570/VA26115Q0744/listing.html)
- Document(s)
- Attachment
- File Name: VA261-15-Q-0744 VA261-15-Q-0744.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2112535&FileName=VA261-15-Q-0744-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2112535&FileName=VA261-15-Q-0744-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA261-15-Q-0744 VA261-15-Q-0744.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2112535&FileName=VA261-15-Q-0744-000.docx)
- Place of Performance
- Address: VA Northern California Health Care System;10535 Hospital Way;Mather, CA
- Zip Code: 95655-4200
- Zip Code: 95655-4200
- Record
- SN03765393-W 20150618/150616234459-3bdb64c3f1dd14e4a6fb3e0438c1deb1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |