DOCUMENT
66 -- POWERLAB CATHETERS - Attachment
- Notice Date
- 6/17/2015
- Notice Type
- Attachment
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
- ZIP Code
- 90815
- Solicitation Number
- VA26215Q0935
- Response Due
- 6/22/2015
- Archive Date
- 8/21/2015
- Point of Contact
- J.PROCTOR
- E-Mail Address
-
6-2204<br
- Small Business Set-Aside
- N/A
- Description
- ITEMDESCRIPTION 1.(SPR-858): The Polyimide SPR-858 Mikro-Tip pressure volume catheter for very large rats has a single pressure sensor (2F). Knowledge of ventricular length of rat heart is required and should be matching. It has 12.5cm effective length with four electrodes. Electrode spacing: E 1-2 = 0.5 mm, E 2-3 = 14.0 mm, E 3-4 = 0.5 mm. Pressure sensor is centered between E2 & E3. Catheter effective length is 30 cm. Low profile pressure connector and Redel electrode connector require PEC-4D Catheter Interface Cable and CEC-10A Connection Cable for Conductance Catheter. Can also be used with the MPVS-Ultra Foundation System. The SPR-858 is reusable and can be repaired. 2.(910-1048)The Volume Calibration Cuvette (2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15 mm Wells) is used to calibrate any of the rat Pressure-Volume Catheters. Using the cuvette relative volume units measured by the conductance method can be converted to true volumes. The cuvette is supplied standard with the PL3508B48/R MPVS-Ultra Single Segment Foundation System for Rats. Please e-mail me if you are able to provide a quote.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/VA26215Q0935/listing.html)
- Document(s)
- Attachment
- File Name: VA262-15-Q-0935 VA262-15-Q-0935_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2114636&FileName=VA262-15-Q-0935-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2114636&FileName=VA262-15-Q-0935-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA262-15-Q-0935 VA262-15-Q-0935_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2114636&FileName=VA262-15-Q-0935-000.docx)
- Place of Performance
- Address: VA SAN DIEGO HEALTHCARE SYSTEM (664);RESEARCH SERVICES (151);3350 LA JOLLA VILLAGE DRIVE;SAN DIEGO, CA
- Zip Code: 92161
- Zip Code: 92161
- Record
- SN03767371-W 20150619/150617235133-8ccad5d17613e165237f52dd7d98148a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |