SOURCES SOUGHT
41 -- VRF System the requirements of the Buy American Act - Construction, FAR 52.225-9
- Notice Date
- 6/24/2015
- Notice Type
- Sources Sought
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- USACE District, Louisville, 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville, KY 40202-2230
- ZIP Code
- 40202-2230
- Solicitation Number
- W912QR-15-VRFUNIT
- Response Due
- 7/9/2015
- Archive Date
- 8/23/2015
- Point of Contact
- Stephanie Craig, 502-315-6204
- E-Mail Address
-
USACE District, Louisville
(stephanie.m.craig@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- A market survey is being conducted to determine if there are a reasonable number of interested businesses that can meet the technical requirements proposed below. If your firm is capable of meeting the requested requirements and you are interested in this project please respond appropriately, negative responses are also encouraged. The proposed project is for a VRF System that meeting the following requirements: Technical Criteria: 1. System shall meet FAR 52.225-9, Buy American Act - Construction 2. System must comply with FAR Part 23.203 and Federal Energy Management Plan Requirement for Energy Star products. 3. System shall have a minimum EER rating of 10.1 4. System shall use variable refrigerant flow (VRF) technology with refrigerant heat recovery. 5. System shall use Refrigerant R-410A 6. System shall be able to maintain system operation at ambient temperature down to zero degrees Fahrenheit. 7. System shall maintain room space temperature/Drift Set of 78 degrees Fahrenheit and Relative Humidity of 50% for cooling and 68 degrees for heating. Submission Requirements: Manufacturers and/or suppliers responding shall submit the technical specifications, as noted below, for ALL units/sizes that meet the minimum technical requirements defined above, as follows: 1. Size/Capacity: 1 ton, 1.5 ton, 2 ton, 3 ton, etc. (12k, 18k, 24k, 36k BTU etc.) 2. EER Rating 3. Refrigerant Type 4. Maximum horizontal and vertical lengths of the refrigerant line set 5. Fixed or Variable Speed Cooling 6. Whether or not the unit has removable access to controls without interrupting airflow and allowing for service without the use of special tools. 7. Type of condensate pan (whether corroding or non-corroding and the type of slope) 8. Wall mounted, floor mounted, or ceiling mounted. 9. Whether the thermostat is internal or external. 10. Whether the fans and compressors are fixed or variable speed. 11. Whether the condenser circuits are or are not pre-piped with tart up and head pressure controls. 12. Whether the unit has a side or top discharge. 13. A catalog cut of the units with technical specification demonstrating all compliant unites shall be included. 14. Provide approximate cost and place of manufacture for each unit. 15. Documentation of product meeting FAR 52.225-9 Buy American Act - Construction 16. Documentation of product meeting FAR Par 23.203 and Federal Energy Management Plan Requirement for Energy Star produces. All interested contractors shall respond to this survey via email by 10:00 am EST on 09 July 2015. Responses shall include (1) identification and verification of the company business size and (2) the requested submissions, as noted above. Email responses to Stephanie Craig at stephanie.m.craig@usace.army.mil. If you have any questions, please contact Stephanie Craig at the email address provided above. This is NOT a Request for Proposal and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-15-VRFUNIT/listing.html)
- Place of Performance
- Address: USACE District, Louisville 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville KY
- Zip Code: 40202-2230
- Zip Code: 40202-2230
- Record
- SN03775686-W 20150626/150625000048-7959cfa26cf42b48f04f7f14f49c66bd (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |