DOCUMENT
65 -- Flowmeters and Regulators - Attachment
- Notice Date
- 7/10/2015
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Southeast Louisiana Veterans HCS;1555 Poydras Street;New Orleans LA 70112
- ZIP Code
- 70112
- Solicitation Number
- VA25615N0832
- Response Due
- 7/21/2015
- Archive Date
- 9/19/2015
- Point of Contact
- Rachel Babin
- E-Mail Address
-
.babin@va.gov<br
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT This is not a solicitation announcement. This is a sources sought synopsis only. The purpose of this is to gain knowledge of potential qualified sources and their size relative to NACIS 339112. Responses will be used by the Government to make appropriate acquisition decisions. Responses are not considered responses to any potential solicitation announcement. The Southeast Louisiana Veterans Health Care System (SLVHCS) New Orleans, LA is seeking responsible sources for a potential contract to provide flowmeters and regulators. All interested firms shall provide the following information: company name, address, point of contact, phone number, email address, capability statement, and business size pursuant to the NAICS code 339112. Responses to this notice shall be e-mailed to Rachel.Babin@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than Tuesday, July 21, 2015 at 10:00 am CST. This notice is to assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Responses are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. ? SYNOPSIS OF SCOPE OF WORK The Contractor shall provide all listed equipment. Oxygen Select Flowmeter "0-15 LPM with 50 PSI take off "Increments: 0.5 LPM from 0.5 to 5 LPM; 1 LPM from 5 to 15 LPM "Accuracy: ± 0.25 LPM from.5 to 5 LPM; ± 0.5 LPM from 5 to 15 LPM "Flush Flow: 60-80 LPM "Backflow compensated "Chrome plated brass body "Shatter resistant polycarbonate Thorpe tube "Allows for connection of 3 devices from a single flowmeter "Flow directions, with a minimum of 2 male tubing barbs and one DISS outlet "Wall connection: DISS Air Flowmeter "0-40 LPM with 50 PSI power take off "0-40 LPM click stops (0. ½, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30 & 40) "Ergonomic Dial-a-Flow dial "Bullet proof light weight polycarbonate "Flow indicator gives visual confirmation of low "Wall connection: DISS "Allows for multiple treatment options from one gas source "Attaches to the outlet of any standard flowmeter "Two male tubing barbs and one DISS outlet Suction Regulator "Modes: Off/ Intermit/Continuous. "0-200 mmHg regulated suction. "Wide view gauge with color-coded fields that can be read from a distance or from the side. "No calibration required "Capability of self-cleaning to prevent flooding and device damage "Validated Reprocessing Methods Utilizing 270 ° F / 4 minutes steam autoclave. "Fine resolution control knob "High-flow bubble barb MRI Compatible Oxygen Flowmeter "0-15 LPM with 50 PSI take off "Increments: 0.5 LPM from 0.5 to 5 LPM; 1 LPM from 5 to 15 LPM "Accuracy: ± 0.25 LPM from.5 to 5 LPM; ± 0.5 LPM from 5 to 15 LPM "Flush Flow: 60-80 LPM "Backflow compensated " Composed of non-magnetic material "Shatter resistant polycarbonate Thorpe tube "Allows for connection of 3 devices from a single flowmeter "Flow directions, with a minimum of 2 male tubing barbs and one DISS outlet "Wall connection: DISS MRI Compatible Air Flowmeter "50 PSI Take Off "Composed of non-magnetic material "0-40 LPM with "0-40 LPM click stops (0. ½, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30 & 40) "Ergonomic Dial-a-Flow dial "Bullet proof light weight polycarbonate "Flow indicator gives visual confirmation of low "Wall connection: DISS "Allows for multiple treatment options from one gas source "Attaches to the outlet of any standard flowmeter "Two male tubing barbs and one DISS outlet MRI Compatible Suction Regulator "Modes: Off/ Intermit/Continuous. "0-200 mmHg regulated suction. "Wide view gauge with color-coded fields that can be read from a distance or from the side "No calibration required "Composed of non-magnetic material "Capability of self-cleaning to prevent flooding and device damage "Validated Reprocessing Methods Utilizing 270 ° F / 4 minutes steam autoclave. "Fine resolution control knob "High-flow bubble barb Neb Drive Oxygen "Calibrated to deliver 8-9 LPM for nebulizer therapy "Non-flow selecting device "DISS "Non-detachable nipple connection "Female Hand Tight
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NOrVAMC/VAMCCO80220/VA25615N0832/listing.html)
- Document(s)
- Attachment
- File Name: VA256-15-N-0832 VA256-15-N-0832_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2160300&FileName=VA256-15-N-0832-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2160300&FileName=VA256-15-N-0832-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-15-N-0832 VA256-15-N-0832_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=2160300&FileName=VA256-15-N-0832-000.docx)
- Place of Performance
- Address: Southeast Louisiana Veterans Health Care System;Warehouse;2400 Canal Street;New Orleans, LA
- Zip Code: 70119
- Zip Code: 70119
- Record
- SN03792580-W 20150712/150710234614-246b447f388356d15bc6d66df75bbcaf (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |